Unsupervised segmentation of multiparameter MRI in experimental cerebral ischemia with comparison to T2, diffusion, and ADC MRI parameters and histopathological validation

被引:0
作者
Jacobs, MA [1 ]
Knight, RA [1 ]
Soltanian-Zadeh, H [1 ]
Zheng, ZG [1 ]
Goussev, AV [1 ]
Peck, DJ [1 ]
Windham, JP [1 ]
Chopp, M [1 ]
机构
[1] Henry Ford Hosp, Ctr Stroke Res, Dept Neurol, Hlth Sci Ctr, Detroit, MI 48202 USA
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 2000年 / 11卷 / 04期
关键词
ISODATA; histopathology (rat); cerebral ischemia; magnetic resonance imaging; image processing; computer assisted; diffusion; tissue signature model;
D O I
10.1002/(SICI)1522-2586(200004)11:4<425::AID-JMRI11>3.0.CO;2-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study presents histological validation of an objective (unsupervised) computer segmentation algorithm, the iterative self-organizing data analysis technique (ISODATA), for analysis of multiparameter magnetic resonance imaging (MRI) data in experimental focal cerebral Ischemia. T2-, T1-, and diffusion (DWI) weighted coronal images were acquired from 4 to 168 hours after stroke on separate groups of animals. Animals were killed immediately after MRI for histological analysis. MR images were coregistered/warped to histology, MRI lesion areas were defined using DWI, apparent diffusion coefficient (ADC) maps, T2-weighted images, and ISODATA. The last techniques clearly discriminated between ischemia-altered and morphologically intact tissue. ISODATA areas were congruent and significantly correlated (r = 0.99, P < 0.05) with histologically defined lesions, In contrast, DWI. ADC, and T2 lesion areas showed no significant correlation with histologically evaluated lesions until subacute time points. These data indicate that multiparameter ISODATA methodology can accurately detect and identify ischemic cell damage early and late after ischemia, with ISODATA outperforming ADC, DWI, and T2-weighted images in identification of Ischemic lesions from 4 to 168 hours after stroke, (C) 2000 Wiley-Liss, Inc.
引用
收藏
页码:425 / 437
页数:13
相关论文
共 72 条
[51]   DIFFUSION-WEIGHTED AND T2-WEIGHTED IMAGING - EVALUATION OF EDEMA REDUCTION IN FOCAL CEREBRAL-ISCHEMIA BY THE CALCIUM AND SEROTONIN ANTAGONIST LEVEMOPAMIL [J].
SEEGA, J ;
ELGER, B .
MAGNETIC RESONANCE IMAGING, 1993, 11 (03) :401-409
[52]  
SEVICK RJ, 1990, ACT NEUR S, V51, P210
[53]   Cathepsin B and middle cerebral artery occlusion in the rat [J].
Seyfried, D ;
Han, YX ;
Zheng, Z ;
Day, N ;
Moin, K ;
Rempel, S ;
Sloane, B ;
Chopp, M .
JOURNAL OF NEUROSURGERY, 1997, 87 (05) :716-723
[54]   A multiresolution approach for contour extraction from brain images [J].
Soltanian-Zadeh, H ;
Windham, JP .
MEDICAL PHYSICS, 1997, 24 (12) :1844-1853
[55]   Semi-supervised segmentation MRI stroke studies [J].
SoltanianZadeh, H ;
Windham, JP ;
Robbins, L .
IMAGE PROCESSING - MEDICAL IMAGING 1997, PTS 1 AND 2, 1997, 3034 :437-448
[56]   A COMPARATIVE-ANALYSIS OF SEVERAL TRANSFORMATIONS FOR ENHANCEMENT AND SEGMENTATION OF MAGNETIC-RESONANCE IMAGE SCENE SEQUENCES [J].
SOLTANIANZADEH, H ;
WINDHAM, JP ;
PECK, DJ ;
YAGLE, AE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :302-318
[57]   ERROR PROPAGATION IN EIGENIMAGE FILTERING [J].
SOLTANIANZADEH, H ;
WINDHAM, JP ;
JENKINS, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (04) :405-420
[58]   OPTIMAL TRANSFORMATION FOR CORRECTING PARTIAL VOLUME AVERAGING EFFECTS IN MAGNETIC-RESONANCE-IMAGING [J].
SOLTANIANZADEH, H ;
WINDHAM, JP ;
YAGLE, AE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1204-1212
[59]   A MULTIDIMENSIONAL NONLINEAR EDGE-PRESERVING FILTER FOR MAGNETIC-RESONANCE IMAGE-RESTORATION [J].
SOLTANIANZADEH, H ;
WINDHAM, JP ;
YAGLE, AE .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1995, 4 (02) :147-161
[60]   Hyperacute stroke: Evaluation with combined multisection diffusion-weighted and hemodynamically weighted echo-planar MR imaging [J].
Sorensen, AG ;
Buonanno, FS ;
Gonzalez, RG ;
Schwamm, LH ;
Lev, MH ;
HuangHellinger, FR ;
Reese, TG ;
Weisskoff, RM ;
Davis, TL ;
Suwanwela, N ;
Can, U ;
Moreira, JA ;
Copen, WA ;
Look, RB ;
Finklestein, SP ;
Rosen, BR ;
Koroshetz, WJ .
RADIOLOGY, 1996, 199 (02) :391-401