A Prospective Trial of 3T and 1.5T Time-of-Flight and Contrast-Enhanced MR Angiography in the Follow-Up of Coiled Intracranial Aneurysms

被引:68
作者
Kaufmann, T. J. [1 ]
Huston, J., III [1 ]
Cloft, H. J. [1 ]
Mandrekar, J. [2 ]
Gray, L. [1 ]
Bernstein, M. A. [1 ]
Atkinson, J. L. [3 ]
Kallmes, D. F. [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Biostat, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Neurosurg, Rochester, MN 55905 USA
关键词
DIGITAL-SUBTRACTION-ANGIOGRAPHY; MAGNETIC-RESONANCE ANGIOGRAPHY; GUGLIELMI DETACHABLE COILS; CEREBRAL ANEURYSMS; ENDOVASCULAR TREATMENT; TESLA; EMBOLIZATION; EXPERIENCE; ADVANTAGE; AGREEMENT;
D O I
10.3174/ajnr.A1932
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE Endovascularly coiled intracranial aneurysms are increasingly being followed up with noninvasive MRA imaging to evaluate for aneurysm recurrences It has not been well-established which MRA techniques are best for this application, however Our aim was to prospectively compare 4 MRA techniques, TOF and CE-MRA at 1 5T and 3T, to a reference standard of DSA in the evaluation of previously endovascularly coiled intracranial aneurysms MATERIALS AND METHODS Fifty-eight subjects with 63 previously coiled intracranial aneurysms underwent all 4 MRA techniques within 8 days of DSA There were 2 outcome variables coil occlusion class (class 1, complete, class 2, dog ear, class 3, residual neck, class 4, aneurysm filling) and change in degree of occlusion since the previous comparison Sensitivity and specificity were computed for each MRA technique relative to the reference standard of DSA Differences among the MRA techniques were evaluated in pair-wise fashion by using the McNemar test RESULTS For the detection of any aneurysm remnant, the sensitivity was 85%-90% for all MRA techniques Sensitivity dropped to 50%-67% when calculated for the detection of only the class 3 and 4 aneurysm remnants, because several class 3 and 4 remnants were misclassified as class 2 by MRA CE-MRA at 1 51 and 3T misclassified fewer of the class 3 and 4 remnants than did TOF-MRA at 1 51, as reflected by the significantly greater sensitivity for larger aneurysm remnants with CE-MRA relative to TOF-MRA at 1 5T (P = 0455 for both comparisons) CONCLUSIONS CE-MRA is more likely than TOF-MRA to classify larger aneurysm remnants appropriately We recommend performing both CE-MRA and TOF-MRA in the follow-up of coiled intracranial aneurysms and at 3T if available
引用
收藏
页码:912 / 918
页数:7
相关论文
共 34 条
[1]   Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries [J].
Al-Kwifi, O ;
Emery, DJ ;
Wilman, AH .
MAGNETIC RESONANCE IMAGING, 2002, 20 (02) :181-187
[2]   Follow-up of coiled cerebral aneurysms at 3T: Comparison of 3D time-of-flight MR angiography and contrast-enhanced MR angiography [J].
Anzalone, N. ;
Scomazzoni, F. ;
Cirillo, M. ;
Righi, C. ;
Simionato, F. ;
Cadioli, M. ;
Iadanza, A. ;
Kirchin, M. A. ;
Scotti, G. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (08) :1530-1536
[3]   Follow-up of coiled cerebral aneurysms: Comparison of three-dimensional time-of-flight magnetic resonance angiography at 3 tesla with three-dimensional time-of-flight magnetic resonance angiography and contrast-enhanced magnetic resonance angiography at 1.5 tesla [J].
Anzalone, Nicoletta ;
Scomazzoni, Francesco ;
Cirillo, Mario ;
Cadioli, Marcello ;
Iadanza, Antonella ;
Kirchin, Miles A. ;
Scotti, Giuseppe .
INVESTIGATIVE RADIOLOGY, 2008, 43 (08) :559-567
[4]  
Bernstein MA, 2001, MAGNET RESON MED, V46, P955, DOI 10.1002/mrm.1282
[5]   Imaging artifacts at 3.OT [J].
Bernstein, Matt A. ;
Huston, John, III ;
Ward, Heidi A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) :735-746
[6]   No advantage of time-of-flight magnetic resonance angiography at 3 Tesla compared to 1.5 Tesla in the follow-up after endovascular treatment of cerebral aneurysms [J].
Buhk, Jan-Hendrik ;
Kallenberg, Kai ;
Mohr, Alexander ;
Dechent, Peter ;
Knauth, Michael .
NEURORADIOLOGY, 2008, 50 (10) :855-861
[7]  
Cloft HJ, 2007, AM J NEURORADIOL, V28, P497
[8]   Follow-up of intracranial aneurysms treated with detachable coils: comparison of plain radiographs, 3D time-of-flight MRA and digital subtraction angiography [J].
Cottier, JP ;
Bleuzen-Couthon, A ;
Gallas, S ;
Vinikoff-Sonier, CB ;
Bertrand, P ;
Domengie, F ;
Barantin, L ;
Herbreteau, D .
NEURORADIOLOGY, 2003, 45 (11) :818-824
[9]  
Deutschmann HA, 2007, AM J NEURORADIOL, V28, P628
[10]   Time-of-flight MR angiography at 3T versus digital subtraction angiography in the imaging follow-up of 51 intracranial aneurysms treated with coils [J].
Ferre, Jean-Christophe ;
Carsin-Nicol, Beatrice ;
Morandi, Xavier ;
Carsin, Michel ;
de Kersaint-Gilly, Axel ;
Gauvrit, Jean-Yves ;
Desal, Hubert-Armand .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (03) :365-369