摘要
Artificial finger joint design has been developed through different stages through the past. PIP (proximal interphalangeal) and MCP (metacarpophalangeal) artificial finger joints have come to replace the amputation and arthrodesis options; although, these artificial joints are still facing challenges related to reactive tissues, reduced range of motion, and flexion and extension deficits. Swanson silicone artificial finger joints are still common due to the physician's preferability of silicone with the dorsal approach during operation. Nevertheless, other artificial finger joints such as the pyrocarbon implant arthroplasty have also drawn the interests of practitioners. Artificial finger joint has been classified under three major categories which are constrained, unconstrained, and linked design. There are also challenges such as concerns of infections and articular cartilage necrosis associated with attempted retention of vascularity. In addition, one of the main challenges facing the silicone artificial finger joints is the fracture occurring at the distal stem with the hinge. The aim of this paper is to review the different artificial finger joints in one paper as there are few old review papers about them. Further studies need to be done to develop the design and materials of the pyrocarbon and silicone implants to increase the range of motion associated with them and the fatigue life of the silicone implants.
引用
收藏
页数:12
相关论文
共 38 条
[31]   Cartilage evaluation in finger joints in healthy controls and early hand osteoarthritis patients using high-resolution MRI [J].
Saltzherr, M. S. ;
Muradin, G. S. R. ;
Haugen, I. K. ;
Selles, R. W. ;
van Neck, J. W. ;
Coert, J. H. ;
Hazes, J. M. W. ;
Luime, J. J. .
OSTEOARTHRITIS AND CARTILAGE, 2019, 27 (08) :1148-1151
[32]   The impact of transferred vascularized toe joint length on motion arc of reconstructed finger proximal interphalangeal joints: a cadaveric study [J].
Hsu, Chung-Chen ;
Loh, Charles Yuen Yung ;
Kao, Dennis ;
Moran, Steven L. ;
Lin, Yu-Te .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2017, 42 (08) :789-793
[33]   Detecting new erosions in rheumatoid arthritis over one year - Radiography and high-resolution computed tomography of finger joints [J].
Therkildsen, Josephine ;
Klose-Jensen, Rasmus ;
Hanel, Mathias ;
Langdahl, Bente L. ;
Thomsen, Jesper S. ;
Manske, Sarah L. ;
Keller, Kresten K. ;
Hauge, Ellen-Margrethe .
JOINT BONE SPINE, 2025, 92 (01)
[34]   Cartilage Quality in Finger Joints: Delayed Gd(DTPA)2- Enhanced MRI of the Cartilage (dGEMRIC) at 3T [J].
Miese, F. R. ;
Ostendorl, B. ;
Wittsack, H-J ;
Reichelt, D. C. ;
Kropil, P. ;
Lanzman, R. S. ;
Mamisch, T. C. ;
Zilkens, C. ;
Jellus, V. ;
Quentin, M. ;
Schneider, M. ;
Scherer, A. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (10) :873-878
[35]   Performance of additively manufactured Ti6Al4V ELI finger joints: biomechanical testing and evaluation for arthritis management [J].
Bussayasripatt, Panaruj ;
Poungsiri, Kitti ;
Yipyintum, Chetarpa ;
Charoenlap, Chris ;
Hongsaprabhas, Chindanai ;
Pataradool, Kawee ;
Tantimethanon, Thanawat ;
Phetrattanarangsi, Thanawat ;
Puncreobutr, Chedtha ;
Lohwongwatana, Boonrat .
MATERIALS TESTING, 2024, 66 (01) :1-8
[36]   Lateral stability in healthy proximal interphalangeal joints versus surface replacement and silicone arthroplasty: Results of a three-dimensional motion analysis study [J].
Hensler, S. ;
Behm, P. ;
Wehrli, M. ;
Marks, M. ;
Ferguson, S. J. ;
Herren, D. B. ;
Schindele, S. .
HAND SURGERY & REHABILITATION, 2020, 39 (04) :296-301
[37]   CORRELATION BETWEEN RANGE OF MOTION AND IMPLANT FRACTURE: A 5 YEAR FOLLOW-UP OF 72 JOINTS IN 18 PATIENTS IN A RANDOMIZED STUDY COMPARING SWANSON AND AVANTA/SUTTER MCP SILICONE PROSTHESIS [J].
Tagil, M. ;
Geijer, M. ;
Malcus, P. ;
Kopylov, P. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (06) :743-747
[38]   Structural damage and inflammation on radiographs or magnetic resonance imaging are associated with cortical interruptions on high-resolution peripheral quantitative computed tomography: a study in finger joints of patients with rheumatoid arthritis and healthy subjects [J].
Scharmga, A. ;
Geusens, P. ;
Peters, M. ;
van den Bergh, J. P. ;
Loeffen, D. ;
Schoonbrood, T. ;
van Rietbergen, B. ;
Vosse, D. ;
Weijers, R. ;
van Tubergen, A. .
SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2018, 47 (06) :431-439