Appendectomy conducted with Single Port Incisionless-Intracorporeal Conventional Equipment-Endoscopic Surgery

被引:22
作者
Akgur, Feza M. [1 ]
Olguner, Mustafa [1 ]
Hakguder, Guelce [1 ]
Ates, Oguz [1 ]
机构
[1] Dokuz Eylul Univ, Tip Fak, Cocuk Cerrahisi Anabilim Dali, TR-35340 Izmir, Turkey
关键词
Laparoscopic appendectomy; Single port; Single conventional port; Single-port access; LAPAROSCOPIC APPENDECTOMY;
D O I
10.1016/j.jpedsurg.2010.01.025
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
In "single conventional port" intracorporeal laparoscopic appendectomy, the appendix is suspended with a transabdominal SLING suture, which replaces the second working instrument (grasper). Thus, the second port is not required. We had modified the SLING suture to SWING suture and renamed our technique as Single Port Incisionless-Intracorporeal Conventional Equipment-Endoscopic Surgery. We herein present our experience with appendectomy conducted by the Single Port Incisionless-Intracorporeal Conventional Equipment-Endoscopic Surgery using the homemade grasper: the SWING suture. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:1061 / 1063
页数:3
相关论文
共 10 条
[1]  
AKGUR FM, 2009, IPEGS 18 ANN C END S
[2]  
ATES O, 2006, DOKUZ EYLUL U TIP FA, V20, P29
[3]  
ATES O, 2005, 23 ANN M TURK ASS PE
[4]   Single-port laparoscopic appendectomy conducted intracorporeally with the aid of a transabdominal sling suture [J].
Ates, Oguz ;
Hakguder, Gulce ;
Olguner, Mustafa ;
Akgur, Feza M. .
JOURNAL OF PEDIATRIC SURGERY, 2007, 42 (06) :1071-1074
[5]   One-trocar appendectomy in pediatric surgery [J].
Esposito, C .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1998, 12 (02) :177-178
[6]   Laparoscopic appendectomy in children performed using single endoscopic GIA stapler for both mesoappendix and base of appendix [J].
Olguner, M ;
Akgür, FM ;
Uçan, B ;
Aktug, T .
JOURNAL OF PEDIATRIC SURGERY, 1998, 33 (09) :1347-1349
[7]   Single-incision laparoscopic surgery: initial urological experience and comparison with natural-orifice transluminal endoscopic surgery [J].
Raman, Jay D. ;
Cadeddu, Jeffrey A. ;
Rao, Pradeep ;
Rane, Abhay .
BJU INTERNATIONAL, 2008, 101 (12) :1493-1496
[8]   Laparoscopic appendectomy with 1.7-mm instruments [J].
Schier, F .
PEDIATRIC SURGERY INTERNATIONAL, 1998, 14 (1-2) :142-143
[9]   The effect of knot geometry on the strength of laparoscopic slip knots [J].
Sharp, HT ;
Dorsey, JH ;
Chovan, JD ;
Holtz, PM .
OBSTETRICS AND GYNECOLOGY, 1996, 88 (03) :408-411
[10]  
Valla J S, 1991, Surg Laparosc Endosc, V1, P166