Highly sensitive determination of mercury using copper enhancer by diamond electrode coupled with sequential injection-anodic stripping voltammetry

被引:29
|
作者
Chaiyo, Sudkate [1 ]
Chailapakul, Orawon [2 ,3 ]
Siangproh, Weena [1 ]
机构
[1] Srinakharinwirot Univ, Fac Sci, Dept Chem, Bangkok, Thailand
[2] Chulalongkorn Univ, Dept Chem, Fac Sci, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Ctr Petr Petrochem & Adv Mat, Bangkok 10330, Thailand
关键词
Mercury; Copper enhancer; Sequential injection-anodic stripping voltammetry (SI-ASV); Boron-doped diamond thin film electrode (BDD); CARBON-PASTE ELECTRODES; SELECTIVE DETERMINATION; GOLD-FILM; METHYLMERCURY; DIGESTION; HG(II);
D O I
10.1016/j.aca.2014.09.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive determination of mercury in the presence of Cu(II) using a boron-doped diamond (BDD) thin film electrode coupled with sequential injection-anodic stripping voltammetry (SI-ASV) was proposed. The Cu(II) was simultaneously deposited with Hg(II) in a 0.5 M HCl supporting electrolyte by electrodeposition. In presence of an excess of Cu(II), the sensitivity for the determination of Hg(II) was remarkably enhanced. Cu(II) and Hg(II) were on-line deposited onto the BDD electrode surface at -1.0 V (vs. Ag/AgCl, 3 M KCl) for 150 s with a flow rate of 14 mL s(-1). An anodic stripping voltammogram was recorded from -0.4 V to 0.25 V using a frequency of 60 Hz, an amplitude of 50 mV, and a step potential of 10 mV at a stopped flow. Under the optimal conditions, well-defined peaks of Cu(II) and Hg(II) were found at -0.25 V and +0.05 V (vs. Ag/AgCl, 3 M KCl), respectively. The detection of Hg(II) showed two linear dynamic ranges (0.1-30.0 ng mL(-1) and 5.0-60.0 ng mL(-1)). The limit of detection (S/N = 3) obtained from the experiment was found to be 0.04 ng mL(-1). The precision values for 10 replicate determinations were 1.1, 2.1 and 2.9% RSD for 0.5, 10 and 20 ng mL(-1), respectively. The proposed method has been successfully applied for the determination of Hg(II) in seawater, salmon, squid, cockle and seaweed samples. A comparison between the proposed method and an inductively coupled plasma optical emission spectrometry (ICP-OES) standard method was performed on the samples, and the concentrations obtained via both methods were in agreement with the certified values of Hg(II), according to the paired t-test at a 95% confidence level. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 46 条
  • [41] Fabrication of carbon nanotube and synthesized Octadentate ligand modified electrode for determination of Hg (II) in Sea water and Lake water using square wave anodic stripping voltammetry
    Gayathri, Jayagopi
    Selvan, Kumar Sangeetha
    Narayanan, Sangilimuthu Sriman
    SENSING AND BIO-SENSING RESEARCH, 2018, 19 : 1 - 6
  • [42] Simultaneous determination of Cd(II) and Pb(II) using square wave anodic stripping voltammetry at a gold nanoparticle-graphene-cysteine composite modified bismuth film electrode
    Zhu, Lian
    Xu, Lili
    Huang, Baozhen
    Jia, Ningming
    Tan, Liang
    Yao, Shouzhuo
    ELECTROCHIMICA ACTA, 2014, 115 : 471 - 477
  • [43] Highly Sensitive Electrochemical Determination of Lead(II) by Double Stranded DNA (dsDNA) with a Carbon Paper/Reduced Graphene Oxide (CP/rGO) Substrate by Differential Pulse Anodic Stripping Voltammetry (DPASV)
    Zhang, Ziwei
    Yuan, Jin
    Zheng, Huiling
    Liu, Zelin
    Lu, Guangqiu
    Huang, Qilin
    Liu, Meichuan
    ANALYTICAL LETTERS, 2023, 56 (07) : 1048 - 1064
  • [44] Electroanalytical Properties of a Thin-Film Mercury–Carbon Electrode of Subnanometric Thickness in High-Speed Linear-Sweep Anodic Stripping Voltammetry as Exemplified by the Determination of Zn(II), Cd(II), and Pb(II)
    G. G. Muntyanu
    Journal of Analytical Chemistry, 2004, 59 : 760 - 767
  • [45] Square Wave Anodic Stripping Voltammetry for Simultaneous Determination of Trace Hg (II) and Tl(I) in Surface Water Samples Using SnO2@ MWCNTs Modified Glassy Carbon Electrode
    Mnyipika, Siyamthanda H.
    Nomngongo, Philiswa N.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (06): : 4811 - 4827
  • [46] Synthesis and characterization of carbon nanotubes/asymmetric novel tetradentate ligand forming complexes on PIGE modified electrode for simultaneous determination of Pb(II) and Hg(II) in sea water, Lake water and well water using anodic stripping voltammetry
    Selvan, Kumar Sangeetha
    Narayanan, Sangilimuthu Sriman
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 810 : 176 - 184