Highly sensitive determination of mercury using copper enhancer by diamond electrode coupled with sequential injection-anodic stripping voltammetry

被引:29
|
作者
Chaiyo, Sudkate [1 ]
Chailapakul, Orawon [2 ,3 ]
Siangproh, Weena [1 ]
机构
[1] Srinakharinwirot Univ, Fac Sci, Dept Chem, Bangkok, Thailand
[2] Chulalongkorn Univ, Dept Chem, Fac Sci, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Ctr Petr Petrochem & Adv Mat, Bangkok 10330, Thailand
关键词
Mercury; Copper enhancer; Sequential injection-anodic stripping voltammetry (SI-ASV); Boron-doped diamond thin film electrode (BDD); CARBON-PASTE ELECTRODES; SELECTIVE DETERMINATION; GOLD-FILM; METHYLMERCURY; DIGESTION; HG(II);
D O I
10.1016/j.aca.2014.09.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive determination of mercury in the presence of Cu(II) using a boron-doped diamond (BDD) thin film electrode coupled with sequential injection-anodic stripping voltammetry (SI-ASV) was proposed. The Cu(II) was simultaneously deposited with Hg(II) in a 0.5 M HCl supporting electrolyte by electrodeposition. In presence of an excess of Cu(II), the sensitivity for the determination of Hg(II) was remarkably enhanced. Cu(II) and Hg(II) were on-line deposited onto the BDD electrode surface at -1.0 V (vs. Ag/AgCl, 3 M KCl) for 150 s with a flow rate of 14 mL s(-1). An anodic stripping voltammogram was recorded from -0.4 V to 0.25 V using a frequency of 60 Hz, an amplitude of 50 mV, and a step potential of 10 mV at a stopped flow. Under the optimal conditions, well-defined peaks of Cu(II) and Hg(II) were found at -0.25 V and +0.05 V (vs. Ag/AgCl, 3 M KCl), respectively. The detection of Hg(II) showed two linear dynamic ranges (0.1-30.0 ng mL(-1) and 5.0-60.0 ng mL(-1)). The limit of detection (S/N = 3) obtained from the experiment was found to be 0.04 ng mL(-1). The precision values for 10 replicate determinations were 1.1, 2.1 and 2.9% RSD for 0.5, 10 and 20 ng mL(-1), respectively. The proposed method has been successfully applied for the determination of Hg(II) in seawater, salmon, squid, cockle and seaweed samples. A comparison between the proposed method and an inductively coupled plasma optical emission spectrometry (ICP-OES) standard method was performed on the samples, and the concentrations obtained via both methods were in agreement with the certified values of Hg(II), according to the paired t-test at a 95% confidence level. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 46 条
  • [31] DETERMINATION OF Cd(II) USING SQUARE WAVE ANODIC STRIPPING VOLTAMMETRY AT A CARBON PASTE ELECTRODE CONTAINING Bi-DOPED CARBON XEROGEL
    Deac, Aglaia Raluca
    Cotet, Liviu Cosmin
    Turdean, Graziella Liana
    Muresan, Liana Maria
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2015, 60 (01): : 203 - 212
  • [32] Gold Nanoparticles-Modified Screen-Printed Electrode for Determination of Pb(II) Ion Using Linear Sweep Anodic Stripping Voltammetry
    Tukur, Salamatu Aliyu
    Yusof, Nor Azah
    Hajian, Reza
    IEEE SENSORS JOURNAL, 2015, 15 (05) : 2780 - 2784
  • [33] Inexpensive and disposable copper mini-sensor modified with bismuth for lead and cadmium determination using square-wave anodic stripping voltammetry
    Figueiredo-Filho, Luiz Carlos S.
    Janegitz, Bruno C.
    Fatibello-Filho, Orlando
    Marcolino-Junior, Luiz Humberto
    Banks, Craig E.
    ANALYTICAL METHODS, 2013, 5 (01) : 202 - 207
  • [34] Ultra trace level determination of fenoxanil by highly sensitive square wave adsorptive stripping voltammetry in real samples with a renewable silver amalgam film electrode
    Brycht, Mariola
    Skrzypek, Slawomira
    Robak, Justyna
    Guzsvany, Valeria
    Vajdle, Olga
    Zbiljic, Jasmina
    Nosal-Wiercinska, Agnieszka
    Guziejewski, Dariusz
    Andrijewski, Grzegorz
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 738 : 69 - 76
  • [35] Electroanalytical characteristics of a subnanometer thin-film mercury-carbon electrode in anodic stripping voltammetry with a linear high-rate potential sweep: Determination of Tl(I)
    G. G. Munteanu
    S. G. Munteanu
    Journal of Analytical Chemistry, 2006, 61 : 266 - 272
  • [36] Carbon Paste Electrode Modified with Organofunctionalized Mesoporous Silica for Electrochemical Detection and Quantitative Determination of Cadmium (II) Using Square Wave Anodic Stripping Voltammetry
    Popa, Dana Elena
    Buleandra, Mihaela
    Mureseanu, Mihaela
    Ionica, Marcel
    Tanase, Ion Gh.
    REVISTA DE CHIMIE, 2010, 61 (02): : 162 - 167
  • [37] TRACE MULTIELEMENT DETERMINATIONS IN REACTOR MODERATOR WATER - SIMULTANEOUS DETERMINATION OF COPPER, GOLD, SILVER AND MERCURY USING DIFFERENTIAL-PULSE STRIPPING VOLTAMMETRY
    ALMON, AC
    ANALYTICA CHIMICA ACTA, 1991, 249 (02) : 447 - 450
  • [38] Hg2+ determination by DPASV by using poly (methylene disulfide)/Au nanoparticle/MWCNT modified glassy carbon electrode by differential pulse anodic stripping voltammetry (DPASV) technique
    Ghalebi, Seyedeh Mina
    Parham, Hooshang
    Shirmardi, Abbas
    JOURNAL OF POROUS MATERIALS, 2024, 31 (01) : 251 - 266
  • [39] Highly sensitive electrocatalytic determination of pyrazinamide using a modified poly(glycine) glassy carbon electrode by square-wave voltammetry
    Ferraz, Bruno R. L.
    Leite, Fernando R. F.
    Malagutti, Andrea R.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2016, 20 (09) : 2509 - 2516
  • [40] Mercury(II) trace detection by a gold nanoparticle-modified glassy carbon electrode using square-wave anodic stripping voltammetry including a chloride desorption step
    Laffont, Laure
    Hezard, Teddy
    Gros, Pierre
    Heimbuerger, Lars-Eric
    Sonke, Jeroen E.
    Behra, Philippe
    Evrard, David
    TALANTA, 2015, 141 : 26 - 32