Highly sensitive determination of mercury using copper enhancer by diamond electrode coupled with sequential injection-anodic stripping voltammetry

被引:29
|
作者
Chaiyo, Sudkate [1 ]
Chailapakul, Orawon [2 ,3 ]
Siangproh, Weena [1 ]
机构
[1] Srinakharinwirot Univ, Fac Sci, Dept Chem, Bangkok, Thailand
[2] Chulalongkorn Univ, Dept Chem, Fac Sci, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Ctr Petr Petrochem & Adv Mat, Bangkok 10330, Thailand
关键词
Mercury; Copper enhancer; Sequential injection-anodic stripping voltammetry (SI-ASV); Boron-doped diamond thin film electrode (BDD); CARBON-PASTE ELECTRODES; SELECTIVE DETERMINATION; GOLD-FILM; METHYLMERCURY; DIGESTION; HG(II);
D O I
10.1016/j.aca.2014.09.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive determination of mercury in the presence of Cu(II) using a boron-doped diamond (BDD) thin film electrode coupled with sequential injection-anodic stripping voltammetry (SI-ASV) was proposed. The Cu(II) was simultaneously deposited with Hg(II) in a 0.5 M HCl supporting electrolyte by electrodeposition. In presence of an excess of Cu(II), the sensitivity for the determination of Hg(II) was remarkably enhanced. Cu(II) and Hg(II) were on-line deposited onto the BDD electrode surface at -1.0 V (vs. Ag/AgCl, 3 M KCl) for 150 s with a flow rate of 14 mL s(-1). An anodic stripping voltammogram was recorded from -0.4 V to 0.25 V using a frequency of 60 Hz, an amplitude of 50 mV, and a step potential of 10 mV at a stopped flow. Under the optimal conditions, well-defined peaks of Cu(II) and Hg(II) were found at -0.25 V and +0.05 V (vs. Ag/AgCl, 3 M KCl), respectively. The detection of Hg(II) showed two linear dynamic ranges (0.1-30.0 ng mL(-1) and 5.0-60.0 ng mL(-1)). The limit of detection (S/N = 3) obtained from the experiment was found to be 0.04 ng mL(-1). The precision values for 10 replicate determinations were 1.1, 2.1 and 2.9% RSD for 0.5, 10 and 20 ng mL(-1), respectively. The proposed method has been successfully applied for the determination of Hg(II) in seawater, salmon, squid, cockle and seaweed samples. A comparison between the proposed method and an inductively coupled plasma optical emission spectrometry (ICP-OES) standard method was performed on the samples, and the concentrations obtained via both methods were in agreement with the certified values of Hg(II), according to the paired t-test at a 95% confidence level. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 46 条
  • [1] Highly Sensitive EQCM Sensor for Mercury Determination by Coupled Stripping Voltammetry
    Dong, Zong-Mu
    Qing, Xu-Miao
    Zhao, Guang-Chao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (03): : 2602 - 2612
  • [2] Determination of mercury and copper in waste water by anodic-stripping voltammetry at the gold electrode
    Bonfil, Y
    Brand, M
    Kirowa-Eisner, E
    REVIEWS IN ANALYTICAL CHEMISTRY, 2000, 19 (3-4): : 201 - 216
  • [3] Parameters affecting the determination of mercury by anodic stripping voltammetry using a gold electrode
    Giacomino, Agnese
    Abollino, Omella
    Malandrino, Mery
    Mentasti, Edoardo
    TALANTA, 2008, 75 (01) : 266 - 273
  • [4] Trace determination of mercury by anodic stripping voltammetry at the rotating gold electrode
    Bonfil, Y
    Brand, M
    Kirowa-Eisner, E
    ANALYTICA CHIMICA ACTA, 2000, 424 (01) : 65 - 76
  • [5] Determination of Ultra-trace Mercury(II) by Flow-injection/Anodic Stripping Voltammetry Using a Track-etched Microporous Membrane Electrode
    Mizuguchi, Hitoshi
    Numata, Kentaro
    Monma, Chiaki
    Iiyama, Masamitsu
    Tachibana, Kazuhiro
    Nishina, Tatsuo
    Shida, Junichi
    ANALYTICAL SCIENCES, 2013, 29 (10) : 949 - 954
  • [6] Copper film electrode for anodic stripping voltammetric determination of trace mercury and lead
    Jovanovski, V.
    Hrastnik, N. I.
    Hocevar, S. B.
    ELECTROCHEMISTRY COMMUNICATIONS, 2015, 57 : 1 - 4
  • [7] Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode
    Abollino, Ornella
    Giacomino, Agnese
    Malandrino, Mery
    Piscionieri, Giuseppina
    Mentasti, Edoardo
    ELECTROANALYSIS, 2008, 20 (01) : 75 - 83
  • [8] Determination of Ultra-trace Mercury(II) by Flow-injection/ Anodic Stripping Voltammetry Using a Track-etched Microporous Membrane Electrode
    Hitoshi Mizuguchi
    Kentaro Numata
    Chiaki Monma
    Masamitsu Iiyama
    Kazuhiro Tachibana
    Tatsuo Nishina
    Junichi Shida
    Analytical Sciences, 2013, 29 : 949 - 954
  • [9] Determination of selenium(IV) by cathodic stripping voltammetry using a copper-modified mercury-film electrode modified with copper
    N. K. Zaitsev
    E. A. Osipova
    D. M. Fedulov
    E. A. Eremenko
    A. G. Dedov
    Journal of Analytical Chemistry, 2006, 61 : 77 - 83
  • [10] Simultaneous determination of lead and copper by anodic stripping voltammetry using a poly(L-glutamic acid) modified electrode
    Xie, Ning
    Ma, Wei
    Gao, Hui
    Sun, Dengming
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2017, 56 (02): : 238 - 242