Highly sensitive determination of mercury using copper enhancer by diamond electrode coupled with sequential injection-anodic stripping voltammetry

被引:29
作者
Chaiyo, Sudkate [1 ]
Chailapakul, Orawon [2 ,3 ]
Siangproh, Weena [1 ]
机构
[1] Srinakharinwirot Univ, Fac Sci, Dept Chem, Bangkok, Thailand
[2] Chulalongkorn Univ, Dept Chem, Fac Sci, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Ctr Petr Petrochem & Adv Mat, Bangkok 10330, Thailand
关键词
Mercury; Copper enhancer; Sequential injection-anodic stripping voltammetry (SI-ASV); Boron-doped diamond thin film electrode (BDD); CARBON-PASTE ELECTRODES; SELECTIVE DETERMINATION; GOLD-FILM; METHYLMERCURY; DIGESTION; HG(II);
D O I
10.1016/j.aca.2014.09.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive determination of mercury in the presence of Cu(II) using a boron-doped diamond (BDD) thin film electrode coupled with sequential injection-anodic stripping voltammetry (SI-ASV) was proposed. The Cu(II) was simultaneously deposited with Hg(II) in a 0.5 M HCl supporting electrolyte by electrodeposition. In presence of an excess of Cu(II), the sensitivity for the determination of Hg(II) was remarkably enhanced. Cu(II) and Hg(II) were on-line deposited onto the BDD electrode surface at -1.0 V (vs. Ag/AgCl, 3 M KCl) for 150 s with a flow rate of 14 mL s(-1). An anodic stripping voltammogram was recorded from -0.4 V to 0.25 V using a frequency of 60 Hz, an amplitude of 50 mV, and a step potential of 10 mV at a stopped flow. Under the optimal conditions, well-defined peaks of Cu(II) and Hg(II) were found at -0.25 V and +0.05 V (vs. Ag/AgCl, 3 M KCl), respectively. The detection of Hg(II) showed two linear dynamic ranges (0.1-30.0 ng mL(-1) and 5.0-60.0 ng mL(-1)). The limit of detection (S/N = 3) obtained from the experiment was found to be 0.04 ng mL(-1). The precision values for 10 replicate determinations were 1.1, 2.1 and 2.9% RSD for 0.5, 10 and 20 ng mL(-1), respectively. The proposed method has been successfully applied for the determination of Hg(II) in seawater, salmon, squid, cockle and seaweed samples. A comparison between the proposed method and an inductively coupled plasma optical emission spectrometry (ICP-OES) standard method was performed on the samples, and the concentrations obtained via both methods were in agreement with the certified values of Hg(II), according to the paired t-test at a 95% confidence level. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 33 条
[1]   Electrochemical synthesis of a gold atomic cluster-chitosan nanocomposite film modified gold electrode for ultra-trace determination of mercury [J].
Aneesh, Padamadathil K. ;
Nambiar, Sindhu R. ;
Rao, Talasila P. ;
Ajayaghosh, Ayyappanpillai .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2014, 16 (18) :8529-8535
[2]   Simple and rapid colorimetric detection of Hg(II) by a paper-based device using silver nanoplates [J].
Apilux, Amara ;
Siangproh, Weena ;
Praphairaksit, Narong ;
Chailapakul, Orawon .
TALANTA, 2012, 97 :388-394
[3]  
Aroui F.E., 2014, J TAIWAN I IN PRESS
[4]   Stripping voltammetric determination of mercury(II) at antimony-coated carbon paste electrode [J].
Ashrafi, Amir M. ;
Vytras, Karel .
TALANTA, 2011, 85 (05) :2700-2702
[5]   Solid phase extraction of trace Hg(II) on silica gel modified with 2-(2-oxoethyl)hydrazine carbothioamide and determination by ICP-AES [J].
Chai, Xiaoli ;
Chang, Xijun ;
Hu, Zheng ;
He, Qun ;
Tu, Zhifeng ;
Li, Zhenhua .
TALANTA, 2010, 82 (05) :1791-1796
[6]   SEQUENTIAL INJECTION-ANALYSIS FOR ELECTROCHEMICAL MEASUREMENTS AND PROCESS ANALYSIS [J].
CHRISTIAN, GD .
ANALYST, 1994, 119 (11) :2309-2314
[7]   Antimony film electrode for stripping voltammetric measurement of Hg(II) in the presence of Cu(II) [J].
Dal Borgo, Sebastiano ;
Jovanovski, Vasko ;
Hocevar, Samo B. .
ELECTROCHIMICA ACTA, 2013, 88 :713-717
[8]  
Drasch G.A., 1994, HDB METALS CLIN ANAL
[9]   Detection of Mercury Ion by Infrared Fluorescent Protein and Its Hydrogel-Based Paper Assay [J].
Gu, Zhen ;
Zhao, Muxun ;
Sheng, Yuewei ;
Bentolila, Laurent A. ;
Tang, Yi .
ANALYTICAL CHEMISTRY, 2011, 83 (06) :2324-2329
[10]   Application of an in situ Bismuth-coated Glassy Carbon Electrode for Electroanalytical Determination of Cd (II) and Pb (II) in Korean Polished Rices [J].
Kim, Hak-Jin ;
Son, Dong-Wook ;
Park, Jong-Min ;
Hwang, Dae Youn ;
Mo, Chang-Youn ;
Park, Sang-Won ;
Kim, Giyoung ;
Eun, Jong-Bang .
FOOD SCIENCE AND BIOTECHNOLOGY, 2010, 19 (05) :1211-1217