Facemasks and aerosol delivery by metered dose inhaler-valved holding chamber in young children: A tight seal makes the difference

被引:28
作者
Janssens, H. M. [1 ]
Tiddens, H. A. W. M. [1 ]
机构
[1] Sophia Childrens Univ Hosp, Erasmus Med Ctr, Dept Pediat Pulm, Rotterdam, Netherlands
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 2007年 / 20卷
关键词
metered dose inhaler; modeling; other;
D O I
10.1089/jam.2007.0578
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A facemask on a valved holding chamber WHO facilitates the inhalation of aerosols from metered dose inhalers (MDI) for young children. Only recently the facemask has been recognized as a vital part for efficient aerosol delivery. Several in vitro and in vivo studies show that a tight seal of the facemask is crucial for optimal aerosol deposition to the lungs. Even a small leak can reduce the dose delivered to the lungs considerably. However, a tight seal is difficult to obtain when a child is not cooperative. Depending on the design of the facemask, it is easier to obtain a good seal. Factors such as dead space, shape, and material should be considered when designing a facemask. However, when a child is upset and not cooperative during the administration, aerosol deposition will be minimal, even with the best-designed facemask.
引用
收藏
页码:S59 / S63
页数:5
相关论文
共 18 条
[1]   Redesigned face mask improves "Real life" aerosol delivery for nebuchamber [J].
Amirav, I ;
Mansour, Y ;
Mandelberg, A ;
Bar-Ilan, I ;
Newhouse, MT .
PEDIATRIC PULMONOLOGY, 2004, 37 (02) :172-177
[2]   Aerosol therapy with valved holding chambers in young children: Importance of the facemask seal [J].
Amirav, I ;
Newhouse, MT .
PEDIATRICS, 2001, 108 (02) :389-394
[3]   THE EFFECT OF DELAY, MULTIPLE ACTUATIONS AND SPACER STATIC CHARGE ON THE IN-VITRO DELIVERY OF BUDESONIDE FROM THE NEBUHALER [J].
BARRY, PW ;
OCALLAGHAN, C .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1995, 40 (01) :76-78
[4]   RELIABLE SALBUTAMOL ADMINISTRATION IN 6-MONTH-OLD TO 36-MONTH-OLD CHILDREN BY MEANS OF A METERED DOSE INHALER AND AEROCHAMBER WITH MASK [J].
CONNER, WT ;
DOLOVICH, MB ;
FRAME, RA ;
NEWHOUSE, MT .
PEDIATRIC PULMONOLOGY, 1989, 6 (04) :263-267
[5]   Aerosol delivery to young children by pMDI-spacer: Is facemask design important? [J].
Esposito-Festen, J ;
Ates, B ;
van Vliet, F ;
Hop, W ;
Tiddens, H .
PEDIATRIC ALLERGY AND IMMUNOLOGY, 2005, 16 (04) :348-353
[6]   Effect of a facemask leak on aerosol delivery from a pMDI-spacer system [J].
Esposito-Festen, JE ;
Ates, B ;
van Vliet, FJM ;
Verbraak, AFM ;
de Jongste, JC ;
Tiddens, HAWM .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2004, 17 (01) :1-6
[7]  
Everard ML, 2000, ARCH DIS CHILD, V82, P428
[8]   DRUG DELIVERY FROM HOLDING CHAMBERS WITH ATTACHED FACEMASK [J].
EVERARD, ML ;
CLARK, AR ;
MILNER, AD .
ARCHIVES OF DISEASE IN CHILDHOOD, 1992, 67 (05) :580-585
[9]   Crying significantly reduces absorption of aerosolised drug in infants [J].
Iles, R ;
Lister, P ;
Edmunds, AT .
ARCHIVES OF DISEASE IN CHILDHOOD, 1999, 81 (02) :163-165
[10]   Determining factors of aerosol deposition for four pMDI-spacer combinations in an infant upper airway model [J].
Janssens, HM ;
Krijgsman, A ;
Verbraak, TFM ;
Hop, WCJ ;
de Jongste, JC ;
Tiddens, HAWM .