Confirming the existence of five peaks in 129Xe rat head spectra

被引:23
作者
Kershaw, Jeff
Nakamura, Kazuhiro
Kondoh, Yasushi
Wakai, Atsushi
Suzuki, Nobuko
Kanno, Iwao
机构
[1] Akita Res Inst Brain & Blood Vessels, Akita, Japan
[2] Akita Ind Promot Fdn, Akita, Japan
[3] Akita Prefectural Univ, Fac Syst Sci & Technol, Honjo, Japan
关键词
rat brain; hyperpolarized xenon; MR spectroscopy; arterial ligation; shimming;
D O I
10.1002/mrm.21186
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A series of experiments were performed to investigate why two peaks (D and E) of the five dissolved phase peaks in hyperpolarized Xe-129 rat head spectra appeared inconsistently in previous work. Specifically, spectra were acquired under conditions of various shim states, anaesthetics, and arterial ligation. The shimming experiments showed that slice-shimming can be used to improve resolution of the dissolved phase peaks, but even so, subtle changes in the shim state that may dramatically alter the shape of peak E remain poorly understood. Also, the inability to shim gas spaces and tissue simultaneously may explain why inconsistent chemical shift values have been reported in the literature. A possible solution for this problem is suggested. The results of pre- and postligation spectra from the same animal indicated that two peaks (A and E) originate from brain. Changing the anaesthetic was found to have no effect on the number of dissolved peaks in xenon spectra.
引用
收藏
页码:791 / 797
页数:7
相关论文
共 20 条
[11]   129Xe spectra from the heads of rats with and without ligation of the external carotid and pterygopalatine arteries [J].
Nakamura, K ;
Kondoh, Y ;
Wakai, A ;
Kershaw, J ;
Wright, D ;
Kanno, I .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) :528-534
[12]  
NAKAMURA K, 2005, P ISMRM, P1145
[13]   Polarized 129Xe optical pumping/spin exchange and delivery system for magnetic resonance spectroscopy and imaging studies [J].
Rosen, MS ;
Chupp, TE ;
Coulter, KP ;
Welsh, RC ;
Swanson, SD .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (02) :1546-1552
[14]  
ROSEN MS, 2001, THESIS U MICHIGAN AN
[15]  
Swanson SD, 1999, MAGNET RESON MED, V42, P1137, DOI 10.1002/(SICI)1522-2594(199912)42:6<1137::AID-MRM19>3.0.CO
[16]  
2-4
[17]   Brain MRI with laser-polarized Xe-129 [J].
Swanson, SD ;
Rosen, MS ;
Agranoff, BW ;
Coulter, KP ;
Welsh, RC ;
Chupp, TE .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) :695-698
[18]   Magnetic resonance imaging with laser-polarized 129Xe [J].
Welsh, RC ;
Chupp, TE ;
Coulter, KP ;
Rosen, MS ;
Swanson, SD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 402 (2-3) :461-463
[19]  
[No title captured]
[20]  
[No title captured]