A Life Cycle Cost Analysis of Structural Insulated Panels for Residential Buildings in a Hot and Arid Climate

被引:7
作者
Dhaif, Muataz [1 ]
Stephan, Andre [2 ]
机构
[1] Univ Melbourne, Fac Architecture Bldg & Planning, Parkville, Vic 3010, Australia
[2] Catholic Univ Louvain, Fac Architecture Architectural Engn & Urban Plann, B-1348 Louvain La Neuve, Belgium
关键词
life cycle cost; life cycle operational energy; residential buildings; structural insulated panels; dynamic energy simulation; cooling; APARTMENT BUILDINGS; ENERGY ANALYSIS; PERFORMANCE; REDUCTION; IMPACT;
D O I
10.3390/buildings11060255
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In hot and humid climatic conditions, cooling tends to dominate building thermal energy use. Cooling loads can be reduced through the adoption of efficient building envelope materials, such as Structural Insulated Panels (SIPs). This study quantifies the life cycle cost and operational energy of a representative case-study house in Bahrain using SIPs and hollow concrete blocks (HCBs) for the envelope over a period of 50 years. Operational energy is calculated using a dynamic energy simulation tool, operational costs are calculated based on the energy demand and local tariff rates, and construction costs are estimated using market prices and quotations. The life cycle cost is quantified using the Net Present Cost technique. Results show that SIPs yield a 20.6% reduction in cooling energy use compared to HCBs. For SIP costs of 12 and 17 USD/m(2), the SIP house was cheaper throughout, or had a higher capital cost than the HCB house (breaking even in year 33), respectively. We propose policy recommendations with respect to material pricing, electricity tariffs, and energy efficiency, to improve the operational energy efficiency of houses in Bahrain and similar countries along the Arabian Peninsula.
引用
收藏
页数:23
相关论文
共 47 条
[1]   An investigation of the impact of building orientation on energy consumption in a domestic building using emerging BIM (Building Information Modelling) [J].
Abanda, F. H. ;
Byers, L. .
ENERGY, 2016, 97 :517-527
[2]  
Abergel T., 2020, Tracking buildings 2020
[3]  
[Anonymous], 2011, 15978 CEN, P66
[4]  
[Anonymous], The Effects of Climate Change
[5]  
Australian Energy Market Commission, 2018, 2018 RES EL PRIC TRE
[6]   Simplified life cycle assessment applied to structural insulated panels homes [J].
Cardenas, Juan Pablo ;
Munoz, Edmundo ;
Riquelme, Cristian ;
Hidalgo, Francisco .
REVISTA INGENIERIA DE CONSTRUCCION, 2015, 30 (01) :33-38
[7]  
Crawford R., 2019, Environmental Performance in Construction (EPiC) Database, DOI [10.26188/5dc228ef98c5a, DOI 10.26188/5DC228EF98C5A, 10.26188/5dc228-f98c5a, DOI 10.26188/5DC228-F98C5A]
[8]   Hybrid life cycle inventory methods - A review [J].
Crawford, Robert H. ;
Bontinck, Paul-Antoine ;
Stephan, Andre ;
Wiedmann, Thomas ;
Yu, Man .
JOURNAL OF CLEANER PRODUCTION, 2018, 172 :1273-1288
[9]   Towards an automated approach for compiling hybrid life cycle inventories [J].
Crawford, Robert H. ;
Bontinck, Paul-Antoine ;
Stephan, Andre ;
Wiedmann, Thomas .
INTERNATIONAL HIGH-PERFORMANCE BUILT ENVIRONMENT CONFERENCE - A SUSTAINABLE BUILT ENVIRONMENT CONFERENCE 2016 SERIES (SBE16), IHBE 2016, 2017, 180 :157-166
[10]  
Department of Energy, SOL DEC TECHN SPOTL