Repeatability of Peripapillary Retinal Nerve Fiber Layer and Inner Retinal Thickness Among Two Spectral Domain Optical Coherence Tomography Devices
被引:46
作者:
Matlach, Juliane
[1
]
Wagner, Martin
[2
,3
]
Malzahn, Uwe
[2
]
Goebel, Winfried
[1
]
机构:
[1] Univ Wurzburg, Dept Ophthalmol, Wurzburg, Germany
[2] Univ Wurzburg, Inst Clin Epidemiol & Biometry, Wurzburg, Germany
[3] Univ Wurzburg, Comprehens Heart Failure Ctr, Wurzburg, Germany
关键词:
OCT;
ganglion cell layer;
inner retina;
RNFL;
Cirrus;
RTVue;
repeatability;
agreement;
SD-OCT;
MACULAR THICKNESS;
TIME-DOMAIN;
REPRODUCIBILITY;
GLAUCOMA;
INSTRUMENTS;
ABILITY;
HEALTHY;
CIRRUS;
D O I:
10.1167/iovs.14-15072
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
PURPOSE. To compare measurement of macular inner retina and peripapillary retinal nerve fiber layer (pRNFL) thickness using two spectral-domain optical coherence tomography (SD-OCT) devices in glaucoma patients, patients with ocular hypertension, idiopathic and atypical Parkinson disease, and healthy controls. METHODS. A total of 171 eyes of 146 participants underwent successful pRNFL and macular scanning and automated measurement of ganglion cell layer + inner plexiform layer (GCL-IPL) using Cirrus HD-OCT or retinal nerve fiber layer + GCL-IPL (RNFL-GCL-IPL) using RTVue-100. Macular RNFL was added to the GCL-IPL thickness measured by Cirrus and was compared to the RNFL-GCL-IPL thickness of the RTVue in the corresponding Cirrus sectors. Intraclass correlation coefficient (ICC) was calculated to determine repeatability of three consecutive measurements; ICC and Bland-Altman analysis to assess agreement between OCTs; Pearson's correlation coefficient to assess strength of linear correlation. RESULTS. Repeatability of average macular RNFL-GCL-IPL thickness measurement was excellent with an ICC of 0.998 for Cirrus and 0.995 for RTVue. Repeatability was also good for average pRNFL thickness measurements. Both instruments demonstrated a good consistency in measurements with ICC values ranging from 0.844 to 0.862 for macular RNFL-GCL-IPL and 0.718 to 0.958 for pRNFL thickness. CONCLUSIONS. Measurement of pRNFL and macular RNFL-GCL-IPL thickness has a high degree of repeatability for both OCT devices. Despite a high correlation between measurements of the two OCT devices and fair to excellent ICC values representing a high consistency in the measurements of the two devices, RTVue measured a thicker macular RNFL-GCL-IPL and pRNFL thickness.
引用
收藏
页码:6536 / 6546
页数:11
相关论文