Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Quantitative Lung Perfusion Imaging Using the Dual-Bolus Approach Comparison of 3 Contrast Agents and Recommendation of Feasible Doses

被引:7
作者
Veldhoen, Simon [1 ]
Oechsner, Markus [2 ]
Fischer, Andre [1 ]
Weng, Andreas Max [1 ]
Kunz, Andreas Steven [1 ]
Bley, Thorsten Alexander [1 ]
Koestler, Herbert [1 ]
Ritter, Christian Oliver [1 ,3 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oderdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Radiat Oncol, D-80290 Munich, Germany
[3] Univ Med Gottingen, Dept Diagnost & Intervent Radiol, Gottingen, Germany
关键词
contrast agents; comparative study; magnetic resonance imaging; lung; perfusion imaging; PULMONARY BLOOD-FLOW; ABSOLUTE QUANTIFICATION; MYOCARDIAL-PERFUSION; MRI; VENTILATION; FIELD; SCINTIGRAPHY; TOMOGRAPHY; DISEASE; MODELS;
D O I
10.1097/RLI.0000000000000224
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aims of this study were to compare 3 contrast agents and to define feasible doses for quantitative lung perfusion imaging using the dual-bolus approach in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI). Materials and Methods Ten healthy volunteers (6 males, 4 females; mean age, 23.5 years) underwent DCE-MRI at 1.5 T using a 3D FLASH sequence. After a prebolus, 3 doses of gadopentetate dimeglumine (Gd-DTPA), gadofosveset, and gadobenate dimeglumine (Gd-BOPTA) were evaluated. Dose regimes were as follows: Gd-DTPA: 3.0 mL, 6.0 mL, and 12.0 mL with 1.5 mL prebolus; gadofosveset: 1.5 mL, 3.0 mL, and 6.0 mL with 0.8 mL prebolus; and Gd-BOPTA: 1.5 mL, 3.0 mL, and 6.0 mL with 0.8 mL prebolus. Pulmonary blood flow (PBF), pulmonary distribution volume, and mean transit time were assessed for each bolus. Region of interest measurements were used to determine the arterial input function (AIF) in the pulmonary trunk and signal intensities in lung parenchyma. Two radiologists independently rated the subjective image quality of the quantitative perfusion maps based on a 4-point Likert scale. Results Dose-dependent signal saturation effects were observed for all 3 contrast agents concerning AIF and parenchyma measurements. Signal yields were comparable using Gd-BOPTA (AIF, 214.49 arbitrary units [AU]; parenchyma, 41.7 AU) and Gd-DTPA (207.43 AU; 36.3 AU). Gadofosveset showed significantly lower signal yield (165.74 AU; 25.2 AU; p < 0.008). Highest signal increase was observed for Gd-DTPA. Using Gd-DTPA, mean PBF values for the 3 doses (3 mL, 6 mL, 12 mL) in mL/min per milliliter lung volume were 2.9 +/- 1.5, 2.4 +/- 1.1, and 1.6 +/- 1.0. For the 3 doses of gadofosveset (1.5 mL, 3 mL, 6 mL) mean PBF results were 3.1 +/- 1.1, 1.9 +/- 0.7, and 1.2 +/- 0.6. Last, mean PBF values for Gd-BOPTA (1.5 mL, 3 mL, 6 mL) were 3.4 +/- 1.7, 2.8 +/- 1.3, and 2.0 +/- 0.8. Measurements provided consistent values for all perfusion parameters (PBF, pulmonary distribution volume, mean transit time) when compared with reference literature. Contrast dose volume and the applied contrast agent had no relevant effects on the image quality scores. Conclusions The dual-bolus approach using a 3D FLASH sequence is a feasible tool for quantitative lung perfusion imaging. Small boluses of 3 mL for Gd-DTPA, 1.5 mL for Gd-BOPTA, and 1.5 mL for gadofosveset provide sufficient signal yield for quantitative parenchyma measurements. Using higher boluses falsely lower perfusion values have to be considered due to signal saturation effects. Although gadofosveset yielded the lowest signal, the generated quantitative perfusion maps were of diagnostic quality.
引用
收藏
页码:186 / 193
页数:8
相关论文
共 32 条
[11]  
2-7
[12]   Assessment of Pulmonary Perfusion With Breath-Hold and Free-Breathing Dynamic Contrast-Enhanced Magnetic Resonance Imaging Quantification and Reproducibility [J].
Ingrisch, Michael ;
Maxien, Daniel ;
Schwab, Felix ;
Reiser, Maximilian F. ;
Nikolaou, Konstantin ;
Dietrich, Olaf .
INVESTIGATIVE RADIOLOGY, 2014, 49 (06) :382-389
[13]   Comparison of different contrast agents and doses for quantitative MR myocardial perfusion imaging [J].
Koestler, Herbert ;
Ritter, Christian ;
Lipp, Michael ;
Beer, Meinrad ;
Hahn, Dietbert ;
Sandstede, Joern .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (02) :382-389
[14]   Prebolus quantitative MR heart perfusion Imaging [J].
Köstler, H ;
Ritter, C ;
Lipp, M ;
Beer, M ;
Hahn, D ;
Sandstede, J .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (02) :296-299
[15]   MR for the Evaluation of Obstructive Pulmonary Disease [J].
Ley-Zaporozhan, Julia ;
Puderbach, Michael ;
Kauczor, Hans-Ulrich .
MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2008, 16 (02) :291-+
[16]   Inflow-weighted pulmonary perfusion: comparison between dynamic contrast-enhanced MRI versus perfusion scintigraphy in complex pulmonary circulation [J].
Lin, Yi-Ru ;
Tsai, Shang-Yueh ;
Huang, Teng-Yi ;
Chung, Hsiao-Wen ;
Huang, Yi-Luan ;
Wu, Fu-Zong ;
Lin, Chu-Chuan ;
Peng, Nan-Jing ;
Wu, Ming-Ting .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
[17]  
Mason R.J., 2010, MURRAY NADELS TXB RE, V5th
[18]   ON THE THEORY OF THE INDICATOR-DILUTION METHOD FOR MEASUREMENT OF BLOOD FLOW AND VOLUME [J].
MEIER, P ;
ZIERLER, KL .
JOURNAL OF APPLIED PHYSIOLOGY, 1954, 6 (12) :731-744
[19]   Quantification of Pulmonary Blood Flow (PBF): Validation of Perfusion MRI and Nonlinear Contrast Agent (CA) Dose Correction With H215O Positron Emission Tomography (PET) [J].
Neeb, Daniel ;
Kunz, Rainer Peter ;
Ley, Sebastian ;
Szabo, Gabor ;
Strauss, Ludwig G. ;
Kauczor, Hans-Ulrich ;
Kreitner, Karl-Friedrich ;
Schreiber, Laura Maria .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (02) :476-487
[20]   Quantification of pulmonary blood flow and volume in healthy volunteers by dynamic contrast-enhanced magnetic resonance imaging using a parallel imaging technique [J].
Nikolaou, K ;
Schoenberg, SO ;
Brix, G ;
Goldman, JP ;
Attenberger, U ;
Kuehn, B ;
Dietrich, O ;
Reiser, MF .
INVESTIGATIVE RADIOLOGY, 2004, 39 (09) :537-545