Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Quantitative Lung Perfusion Imaging Using the Dual-Bolus Approach Comparison of 3 Contrast Agents and Recommendation of Feasible Doses

被引:7
作者
Veldhoen, Simon [1 ]
Oechsner, Markus [2 ]
Fischer, Andre [1 ]
Weng, Andreas Max [1 ]
Kunz, Andreas Steven [1 ]
Bley, Thorsten Alexander [1 ]
Koestler, Herbert [1 ]
Ritter, Christian Oliver [1 ,3 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oderdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Radiat Oncol, D-80290 Munich, Germany
[3] Univ Med Gottingen, Dept Diagnost & Intervent Radiol, Gottingen, Germany
关键词
contrast agents; comparative study; magnetic resonance imaging; lung; perfusion imaging; PULMONARY BLOOD-FLOW; ABSOLUTE QUANTIFICATION; MYOCARDIAL-PERFUSION; MRI; VENTILATION; FIELD; SCINTIGRAPHY; TOMOGRAPHY; DISEASE; MODELS;
D O I
10.1097/RLI.0000000000000224
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aims of this study were to compare 3 contrast agents and to define feasible doses for quantitative lung perfusion imaging using the dual-bolus approach in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI). Materials and Methods Ten healthy volunteers (6 males, 4 females; mean age, 23.5 years) underwent DCE-MRI at 1.5 T using a 3D FLASH sequence. After a prebolus, 3 doses of gadopentetate dimeglumine (Gd-DTPA), gadofosveset, and gadobenate dimeglumine (Gd-BOPTA) were evaluated. Dose regimes were as follows: Gd-DTPA: 3.0 mL, 6.0 mL, and 12.0 mL with 1.5 mL prebolus; gadofosveset: 1.5 mL, 3.0 mL, and 6.0 mL with 0.8 mL prebolus; and Gd-BOPTA: 1.5 mL, 3.0 mL, and 6.0 mL with 0.8 mL prebolus. Pulmonary blood flow (PBF), pulmonary distribution volume, and mean transit time were assessed for each bolus. Region of interest measurements were used to determine the arterial input function (AIF) in the pulmonary trunk and signal intensities in lung parenchyma. Two radiologists independently rated the subjective image quality of the quantitative perfusion maps based on a 4-point Likert scale. Results Dose-dependent signal saturation effects were observed for all 3 contrast agents concerning AIF and parenchyma measurements. Signal yields were comparable using Gd-BOPTA (AIF, 214.49 arbitrary units [AU]; parenchyma, 41.7 AU) and Gd-DTPA (207.43 AU; 36.3 AU). Gadofosveset showed significantly lower signal yield (165.74 AU; 25.2 AU; p < 0.008). Highest signal increase was observed for Gd-DTPA. Using Gd-DTPA, mean PBF values for the 3 doses (3 mL, 6 mL, 12 mL) in mL/min per milliliter lung volume were 2.9 +/- 1.5, 2.4 +/- 1.1, and 1.6 +/- 1.0. For the 3 doses of gadofosveset (1.5 mL, 3 mL, 6 mL) mean PBF results were 3.1 +/- 1.1, 1.9 +/- 0.7, and 1.2 +/- 0.6. Last, mean PBF values for Gd-BOPTA (1.5 mL, 3 mL, 6 mL) were 3.4 +/- 1.7, 2.8 +/- 1.3, and 2.0 +/- 0.8. Measurements provided consistent values for all perfusion parameters (PBF, pulmonary distribution volume, mean transit time) when compared with reference literature. Contrast dose volume and the applied contrast agent had no relevant effects on the image quality scores. Conclusions The dual-bolus approach using a 3D FLASH sequence is a feasible tool for quantitative lung perfusion imaging. Small boluses of 3 mL for Gd-DTPA, 1.5 mL for Gd-BOPTA, and 1.5 mL for gadofosveset provide sufficient signal yield for quantitative parenchyma measurements. Using higher boluses falsely lower perfusion values have to be considered due to signal saturation effects. Although gadofosveset yielded the lowest signal, the generated quantitative perfusion maps were of diagnostic quality.
引用
收藏
页码:186 / 193
页数:8
相关论文
共 32 条
[1]   Non-Contrast-Enhanced Perfusion and Ventilation Assessment of the Human Lung by Means of Fourier Decomposition in Proton MRI [J].
Bauman, Grzegorz ;
Puderbach, Michael ;
Deimling, Michael ;
Jellus, Vladimir ;
Chefd'hotel, Christophe ;
Dinkel, Julien ;
Hintze, Christian ;
Kauczor, Hans-Ulrich ;
Schad, Lothar R. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (03) :656-664
[2]   Comparison of Models and Contrast Agents for Improved Signal and Signal Linearity in Dynamic Contrast-Enhanced Pulmonary Magnetic Resonance Imaging [J].
Bell, Laura C. ;
Wang, Kang ;
Del Rio, Alejandro Munoz ;
Grist, Thomas M. ;
Fain, Sean B. ;
Nagle, Scott K. .
INVESTIGATIVE RADIOLOGY, 2015, 50 (03) :174-178
[3]   CONTRAST-ENHANCED MR IMAGING OF THE LUNG - ASSESSMENTS OF VENTILATION AND PERFUSION [J].
BERTHEZENE, Y ;
VEXLER, V ;
CLEMENT, O ;
MUHLER, A ;
MOSELEY, ME ;
BRASCH, RC .
RADIOLOGY, 1992, 183 (03) :667-672
[4]   Functional Magnetic Resonance Imaging of the Lung [J].
Biederer, J. ;
Heussel, C. P. ;
Puderbach, M. ;
Wielpuetz, M. O. .
SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 35 (01) :74-82
[5]   Field Strength Dependence of R1 and R2* Relaxivities of Human Whole Blood to ProHance, Vasovist, and Deoxyhemoglobin [J].
Blockley, N. P. ;
Jiang, L. ;
Gardener, A. G. ;
Ludman, C. N. ;
Francis, S. T. ;
Gowland, P. A. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) :1313-1320
[6]   Pulmonary disorders: Ventilation-perfusion MR imaging with animal models [J].
Chen, Q ;
Levin, DL ;
Kim, D ;
David, V ;
McNicholas, M ;
Chen, V ;
Jakob, PM ;
Griswold, MA ;
Goldfarb, JW ;
Hatabu, H ;
Edelman, RR .
RADIOLOGY, 1999, 213 (03) :871-879
[7]   Estimation of the radiation dose from thoracic CT scans in a cystic fibrosis population [J].
Donadieu, Jean ;
Roadier, Candice ;
Saguintaah, Alagah ;
Maccia, Carlo ;
Chiron, Raphael .
CHEST, 2007, 132 (04) :1233-1238
[8]   Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy [J].
Dournes, Gael ;
Verdier, Damien ;
Montaudon, Michel ;
Bullier, Eric ;
Riviere, Annalisa ;
Dromer, Claire ;
Picard, Francois ;
Billes, Marc-Alain ;
Corneloup, Olivier ;
Laurent, Francois ;
Lederlin, Mathieu .
EUROPEAN RADIOLOGY, 2014, 24 (01) :42-51
[9]   Effect of inspiratory and expiratory breathhold on pulmonary perfusion - Assessment by pulmonary perfusion magnetic resonance Imaging [J].
Fink, C ;
Ley, S ;
Risse, F ;
Eichinger, M ;
Zaporozhan, J ;
Buhmann, R ;
Puderbach, M ;
Plathow, C ;
Kauczor, HU .
INVESTIGATIVE RADIOLOGY, 2005, 40 (02) :72-79
[10]  
Hatabu H, 1999, MAGNET RESON MED, V42, P1033, DOI 10.1002/(SICI)1522-2594(199912)42:6<1033::AID-MRM7>3.0.CO