A fluorescent probe for intracellular cysteine overcoming the interference by glutathione

被引:76
|
作者
Tian, Minggang [1 ]
Guo, Fuqiang [1 ,7 ]
Sun, Yuming [2 ]
Zhang, Weijia [1 ]
Miao, Fang [1 ]
Liu, Yong [1 ]
Song, Guofen [1 ]
Ho, Cheuk-Lam [3 ,4 ,5 ]
Yu, Xiaoqiang [1 ]
Sun, Jing Zhi [6 ]
Wong, Wai-Yeung [3 ,4 ,5 ,8 ]
机构
[1] Shandong Univ, State Key Lab Crystal Mat, Ctr Bio & Micro Nano Funct Mat, Jinan 250100, Peoples R China
[2] Shandong Univ, Sch Informat Sci & Engn, Jinan 250100, Peoples R China
[3] Hong Kong Baptist Univ, Inst Mol Funct Mat, Hong Kong, Hong Kong, Peoples R China
[4] Hong Kong Baptist Univ, Dept Chem, Hong Kong, Hong Kong, Peoples R China
[5] Hong Kong Baptist Univ, Partner State Key Lab Environm & Biol Anal, Hong Kong, Hong Kong, Peoples R China
[6] Zhejiang Univ, Dept Polymer Sci & Engn, MoE Key Lab Macromol Synth & Functionalizat, Hangzhou 310027, Peoples R China
[7] Changji Univ, Dept Phys, Xinjiang 831100, Changji, Peoples R China
[8] S China Univ Technol, Inst Polymer Optoelect Mat & Devices, State Key Lab Luminescent Mat & Devices, Guangzhou 510640, Peoples R China
基金
中国国家自然科学基金;
关键词
LIVING CELLS; TOTAL HOMOCYSTEINE; CYSTEINE/HOMOCYSTEINE; AGGREGATION; ELECTRODE; PLASMA; THIOLS;
D O I
10.1039/c4ob00382a
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
Cysteine (Cys) plays important roles in many physiological processes of eukaryotic cells and its detection in cells is of fundamental significance. However, glutathione (GSH), homocysteine, N-acetyl-L-cysteine and other thiols greatly hamper the detection of Cys. In particular, GSH strongly interferes with the detection of cellular Cys (30-200 mu M) due to its high intracellular concentration (1-10 mM). In this work, an off on fluorescent probe (HOTA) for the detection of Cys is presented. This probe possesses both excellent sensitivity and satisfactory selectivity for cellular Cys detection: with the addition of 200 mu M Cys, the fluorescence intensity of the probe (10 mu M) enhanced 117-fold and the detection limit was calculated to be 13.47 mu M, which is lower than the cellular Cys concentration; the probe also selectively detected 30-200 mu M cysteine over 1-10 mM glutathione. Consequently, cell imaging experiments were performed with probe HOTA. Furthermore, the results of the thiol-blocking and GSH synthesis inhibiting experiments confirmed that the intracellular emission mainly originates from the interaction between Cys and HOTA.
引用
收藏
页码:6128 / 6133
页数:6
相关论文
共 50 条
  • [21] A visual and "turn-on" fluorescent probe for rapid detection of cysteine over homocysteine and glutathione
    Li, Hongda
    Jin, Longyi
    Kan, Yuhe
    Yin, Bingzhu
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 546 - 554
  • [22] A simple colorimetric and fluorescent probe with high selectivity towards cysteine over homocysteine and glutathione
    Guo, Jing
    Kuai, Ziyu
    Zhang, Zhixiang
    Yang, Qingbiao
    Shan, Yaming
    Li, Yaoxian
    RSC ADVANCES, 2017, 7 (31) : 18867 - 18873
  • [23] A new turn-on fluorescent probe for selective detection of glutathione and cysteine in living cells
    Wei, Mingjie
    Yin, Peng
    Shen, Youming
    Zhang, Lingli
    Deng, Jianhui
    Xue, Shanyan
    Li, Haitao
    Guo, Bin
    Zhang, Youyu
    Yao, Shouzhuo
    CHEMICAL COMMUNICATIONS, 2013, 49 (41) : 4640 - 4642
  • [24] INTRACELLULAR CYSTEINE AND GLUTATHIONE DELIVERY SYSTEMS
    MEISTER, A
    ANDERSON, ME
    HWANG, O
    JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 1986, 5 (02) : 137 - 151
  • [25] The Fluorescent Probe for Detecting Glutathione
    Yan, Fanyong
    Zang, Yueyan
    Zhang, Yuyang
    Li, Xiang
    Wang, Ruijie
    Lu, Zhentong
    PROGRESS IN CHEMISTRY, 2022, 34 (05) : 1136 - 1152
  • [26] Highly selective discrimination of cysteine from glutathione and homo-cysteine with a novel AIE-ESIPT fluorescent probe
    Feng, Bin
    Liu, Yi
    Huang, Shuai
    Huang, Xueyan
    Huang, Liu
    Liu, Min
    Wu, Jiaxin
    Du, Tao
    Wang, Shuanglian
    Feng, Xueping
    Zeng, Wenbin
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 325
  • [27] Oxidized-morpholine dressing ratiometric fluorescent probe for specifically visualizing the intracellular glutathione
    Liu, Guotao
    Han, Xie
    Zhang, Jing
    Xu, Zhiqiang
    Liu, Sheng Hua
    Zeng, Lintao
    Yin, Jun
    DYES AND PIGMENTS, 2018, 148 : 292 - 297
  • [28] Designing an Intracellular Fluorescent Probe for Glutathione: Two Modulation Sites for Selective Signal Transduction
    Isik, Murat
    Guliyev, Ruslan
    Kolemen, Safacan
    Altay, Yigit
    Senturk, Berna
    Tekinay, Turgay
    Akkaya, Engin U.
    ORGANIC LETTERS, 2014, 16 (12) : 3260 - 3263
  • [29] Simultaneous sensing of cysteine/homocysteine and glutathione with a fluorescent probe based on a single atom replacement strategy
    Yao, Jingfeng
    Yin, Guoxing
    Yu, Ting
    Li, Haitao
    Yin, Peng
    ANALYTICAL METHODS, 2021, 13 (11) : 1358 - 1363
  • [30] Screening and investigation of a cyanine fluorescent probe for simultaneous sensing of glutathione and cysteine under single excitation
    Wang, Xu
    Lv, Jianzheng
    Yao, Xueying
    Li, Yong
    Huang, Fang
    Li, Mengmeng
    Yang, Jie
    Ruan, Xiuyun
    Tang, Bo
    CHEMICAL COMMUNICATIONS, 2014, 50 (97) : 15439 - 15442