A fluorescent probe for intracellular cysteine overcoming the interference by glutathione

被引:76
|
作者
Tian, Minggang [1 ]
Guo, Fuqiang [1 ,7 ]
Sun, Yuming [2 ]
Zhang, Weijia [1 ]
Miao, Fang [1 ]
Liu, Yong [1 ]
Song, Guofen [1 ]
Ho, Cheuk-Lam [3 ,4 ,5 ]
Yu, Xiaoqiang [1 ]
Sun, Jing Zhi [6 ]
Wong, Wai-Yeung [3 ,4 ,5 ,8 ]
机构
[1] Shandong Univ, State Key Lab Crystal Mat, Ctr Bio & Micro Nano Funct Mat, Jinan 250100, Peoples R China
[2] Shandong Univ, Sch Informat Sci & Engn, Jinan 250100, Peoples R China
[3] Hong Kong Baptist Univ, Inst Mol Funct Mat, Hong Kong, Hong Kong, Peoples R China
[4] Hong Kong Baptist Univ, Dept Chem, Hong Kong, Hong Kong, Peoples R China
[5] Hong Kong Baptist Univ, Partner State Key Lab Environm & Biol Anal, Hong Kong, Hong Kong, Peoples R China
[6] Zhejiang Univ, Dept Polymer Sci & Engn, MoE Key Lab Macromol Synth & Functionalizat, Hangzhou 310027, Peoples R China
[7] Changji Univ, Dept Phys, Xinjiang 831100, Changji, Peoples R China
[8] S China Univ Technol, Inst Polymer Optoelect Mat & Devices, State Key Lab Luminescent Mat & Devices, Guangzhou 510640, Peoples R China
基金
中国国家自然科学基金;
关键词
LIVING CELLS; TOTAL HOMOCYSTEINE; CYSTEINE/HOMOCYSTEINE; AGGREGATION; ELECTRODE; PLASMA; THIOLS;
D O I
10.1039/c4ob00382a
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
Cysteine (Cys) plays important roles in many physiological processes of eukaryotic cells and its detection in cells is of fundamental significance. However, glutathione (GSH), homocysteine, N-acetyl-L-cysteine and other thiols greatly hamper the detection of Cys. In particular, GSH strongly interferes with the detection of cellular Cys (30-200 mu M) due to its high intracellular concentration (1-10 mM). In this work, an off on fluorescent probe (HOTA) for the detection of Cys is presented. This probe possesses both excellent sensitivity and satisfactory selectivity for cellular Cys detection: with the addition of 200 mu M Cys, the fluorescence intensity of the probe (10 mu M) enhanced 117-fold and the detection limit was calculated to be 13.47 mu M, which is lower than the cellular Cys concentration; the probe also selectively detected 30-200 mu M cysteine over 1-10 mM glutathione. Consequently, cell imaging experiments were performed with probe HOTA. Furthermore, the results of the thiol-blocking and GSH synthesis inhibiting experiments confirmed that the intracellular emission mainly originates from the interaction between Cys and HOTA.
引用
收藏
页码:6128 / 6133
页数:6
相关论文
共 50 条
  • [1] Development of a NIR fluorescent probe for the detection of intracellular cysteine and glutathione and the monitoring of the drug resistance
    Lu, Xinmiao
    Wu, Muyu
    Wang, Siwen
    Qin, Jingcan
    Li, Peiyong
    TALANTA, 2021, 235
  • [2] A Mitochondria-Targetable Fluorescent Probe for Dual-Channel NO Imaging Assisted by Intracellular Cysteine and Glutathione
    Sun, Yuan-Qiang
    Liu, Jing
    Zhang, Hongxing
    Huo, Yingying
    Lv, Xin
    Shi, Yawei
    Guo, Wei
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2014, 136 (36) : 12520 - 12523
  • [3] A fluorescent probe for discrimination of cysteine/homocysteine, glutathione and hydrogen polysulfides
    Puhui Xie
    Yanru Zhu
    Yanliang Wang
    Guangqin Gao
    Song Jiang
    Fengqi Guo
    Research on Chemical Intermediates, 2021, 47 : 1123 - 1138
  • [4] A multi-emissive fluorescent probe for the discrimination of glutathione and cysteine
    Liu, Xue-Liang
    Niu, Li-Ya
    Chen, Yu-Zhe
    Yang, Yunxu
    Yang, Qing-Zheng
    BIOSENSORS & BIOELECTRONICS, 2017, 90 : 403 - 409
  • [5] A fluorescent probe for discrimination of cysteine/homocysteine, glutathione and hydrogen polysulfides
    Xie, Puhui
    Zhu, Yanru
    Wang, Yanliang
    Gao, Guangqin
    Jiang, Song
    Guo, Fengqi
    RESEARCH ON CHEMICAL INTERMEDIATES, 2021, 47 (03) : 1123 - 1138
  • [6] A Fast Dual-responsive OFF-ON Fluorescent Probe for Cysteine and Glutathione without Interference from Homocysteine
    Fu, Qingjie
    Liu, Ruxin
    Cui, Xiaoqian
    Zhao, Yuqi
    Chi, Hui
    Lu, Yongzhuang
    Fei, Qiang
    Feng, Guodong
    Shan, Hongyan
    Huan, Yanfu
    Analytical Sciences, 2021, 37 (11): : 1541 - 1546
  • [7] A Fast Dual-responsive OFF-ON Fluorescent Probe for Cysteine and Glutathione without Interference from Homocysteine
    Fu, Qingjie
    Liu, Ruxin
    Cui, Xiaoqian
    Zhao, Yuqi
    Chi, Hui
    Lu, Yongzhuang
    Fei, Qiang
    Feng, Guodong
    Shan, Hongyan
    Huan, Yanfu
    ANALYTICAL SCIENCES, 2021, 37 (11) : 1541 - +
  • [8] A Fast Dual-responsive OFF-ON Fluorescent Probe for Cysteine and Glutathione without Interference from Homocysteine
    Qingjie Fu
    Ruxin Liu
    Xiaoqian Cui
    Yuqi Zhao
    Hui Chi
    Yongzhuang Lu
    Qiang Fei
    Guodong Feng
    Hongyan Shan
    Yanfu Huan
    Analytical Sciences, 2021, 37 : 1541 - 1546
  • [9] A ratiometric fluorescent probe for cysteine and glutathione differentiation and its application for cysteine detection in foods
    You, Wenhui
    Huang, Shumei
    Chen, Gang
    Lin, Zhenxin
    Jiang, Yin
    Qian, Jiang
    Zhang, Huatang
    Sun, Hongyan
    JOURNAL OF MOLECULAR STRUCTURE, 2024, 1315
  • [10] Construction of a ratiometric probe with dual quenching mechanisms for selectively imaging intracellular sulfur dioxide overcoming the interference from cysteine
    Zhang, Qilong
    Cui, Zhongqian
    Wang, Qiufen
    Zheng, Gengxiu
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 295 : 79 - 85