Patient, procedural, and hardware factors associated with pacemaker lead failures in pediatrics and congenital heart disease

被引:180
作者
Fortescue, EB
Berul, CI
Cecchin, F
Walsh, EP
Triedman, JK
Alexander, ME
机构
[1] Childrens Hosp, Dept Cardiol, Arrhythmia Serv, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USA
关键词
pediatric; pacemaker; lead failure; risk;
D O I
10.1016/j.hrthm.2004.02.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES To examine outcomes of children with pacemakers over a 22-year period and identify risk factors for lead failure. BACKGROUND Small patient size, structural cardiac abnormalities, and growth may complicate pediatric pacemaker management. Better knowledge of risk factors for lead failure in these patients may help improve future outcomes. METHODS All pacemaker patients followed at one pediatric center 1980-2002 were included. Lead failures were identified retrospectively as leads repaired, replaced, or abandoned due to fracture, insulation break, dislodgement, or abnormalities in pacing or sensing. Risk factors were identified using logistic regression and Cox analyses. RESULTS A total of 1007 leads were implanted in 497 patients during the study period (5175 lead-years). Median age at implant was 9 years (0-55); 64% of patients had structural congenital heart disease. Median follow-up time was 6.2 years (0-22). Lead failure occurred in 155 leads (15%), and 115 patients (23%), with 28% of patients experiencing multiple failures. Significant independent correlates of lead failure included age <12 years at implant, history of structural congenital heart defects, and epicardial lead placement. Younger patients (<12 years) experienced significantly more lead fractures than older children (P = .005), while patients with congenital heart defects experienced more exit block. Epicardial leads were more likely to fail due to fracture or exit block, while transvenous leads failed more due to insulation breaks or dislodgements. CONCLUSIONS Pediatric pacing patients have a high incidence lead failures. These occur most commonly in younger patients, structural congenital heart disease, and those with epicardial lead systems. Approaches to pacing system implantation and follow-up in these patients need to be individualized, with special attention to minimizing risk of lead failures. Our findings suggest that expanded utilization of transvenous systems in smaller patients seems justified when anatomy permits. 2004 Heart Rhythm Society. All rights reserved.
引用
收藏
页码:150 / 159
页数:10
相关论文
共 30 条
[1]  
Beaufort-Krol GCM, 1999, J THORAC CARDIOV SUR, V117, P523
[2]  
BERUL CI, 2001, 22 ANN SCI SESS N AM, V24, P329
[3]  
Berul CI, 2001, CARDIAC ARRHYTHMIAS, P301
[4]   Cardiac pacing in children [J].
Bevilacqua, L ;
Hordof, A .
CURRENT OPINION IN CARDIOLOGY, 1998, 13 (01) :48-55
[5]   Clinical study of the laser sheath for lead extraction: The total experience in the United States [J].
Byrd, CL ;
Wilkoff, BL ;
Love, CJ ;
Sellers, TD ;
Reiser, C .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (05) :804-808
[6]  
Cohen MI, 2001, CIRCULATION, V103, P2585
[7]   Implantable cardioverter defibrillator lead complications and laser extraction in children and young adults with congenital heart disease: Implications for implantation and management [J].
Cooper, JM ;
Stephenson, EA ;
Berul, CI ;
Walsh, EP ;
Epstein, LM .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (04) :344-349
[8]  
Crossley George H., 2000, Cardiology Clinics, V18, P95, DOI 10.1016/S0733-8651(05)70130-2
[9]   STEROID ELUTION IMPROVES THE STIMULATION THRESHOLD IN AN ACTIVE-FIXATION ATRIAL PERMANENT PACING LEAD - A RANDOMIZED, CONTROLLED-STUDY [J].
CROSSLEY, GH ;
BRINKER, JA ;
REYNOLDS, D ;
SPENCER, W ;
JOHNSON, WB ;
HURD, H ;
TONDER, L ;
ZMIJEWSKI, M .
CIRCULATION, 1995, 92 (10) :2935-2939
[10]   RISKS AND BENEFITS OF CARDIAC PACING IN CHILDREN [J].
ENNKER, J ;
STEGMANN, T ;
LUHMER, I ;
OELERT, H .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1985, 8 (02) :125-134