Design and Computational Validation of a Novel Bioreactor for Conditioning Vascular Tissue to Time-Varying Multidirectional Fluid Shear Stress

被引:3
作者
Liu, Janet [1 ]
Cornelius, Kurtis [1 ]
Graham, Mathew [1 ]
Leonard, Tremayne [1 ]
Tipton, Austin [1 ]
Yorde, Abram [1 ]
Sucosky, Philippe [1 ]
机构
[1] Wright State Univ, Dept Mech & Mat Engn, 257 Russ Engn Ctr, Dayton, OH 45435 USA
基金
美国国家科学基金会;
关键词
Cardiovascular; Fluid wall shear stress; Mechanobiology; Hemodynamics; Directionality; AORTIC-VALVE HEMODYNAMICS; FLOW PATTERNS; INTRACRANIAL ANEURYSMS; ENDOTHELIAL-CELLS; SECONDARY FLOW; BLOOD-FLOW; MECHANISMS; ARCH;
D O I
10.1007/s13239-019-00426-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose The cardiovascular endothelium experiences pulsatile and multidirectional fluid wall shear stress (WSS). While the effects of non-physiologic WSS magnitude and pulsatility on cardiovascular function have been studied extensively, the impact of directional abnormalities remains unknown due to the challenge to replicate this characteristic in vitro. To address this gap, this study aimed at designing a bioreactor capable of subjecting cardiovascular tissue to time-varying WSS magnitude and directionality. Methods The device consisted of a modified cone-and-plate bioreactor. The cone rotation generates a fluid flow subjecting tissue to desired WSS magnitude, while WSS directionality is achieved by altering the alignment of the tissue relative to the flow at each instant of time. Computational fluid dynamics was used to verify the device ability to replicate the native WSS of the proximal aorta. Cone and tissue mount velocities were determined using an iterative optimization procedure. Results Using conditions derived from cone-and-plate theory, the initial simulations yielded root-mean-square errors of 22.8 and 8.4% in WSS magnitude and angle, respectively, between the predicted and the target signals over one cycle, relative to the time-averaged target values. The conditions obtained after two optimization iterations reduced those errors to 3.5 and 0.5%, respectively, and generated 0.2% and 0.01% difference in time-averaged WSS magnitude and angle, respectively, relative to the target waveforms. Conclusions A bioreactor capable of generating simultaneously desired time-varying WSS magnitude and directionality was designed and validated computationally. The ability to subject tissue to in vivo-like WSS will provide new insights into cardiovascular mechanobiology and disease.
引用
收藏
页码:531 / 542
页数:12
相关论文
共 49 条
  • [1] [Anonymous], 2010, Cardiovasc. Eng. Technol, DOI [10.1007/s13239-010-0015-5, DOI 10.1007/S13239-010-0015-5]
  • [2] Mechanobiology in Cardiovascular Disease Management: potential Strategies and Current needs
    Atkins, Samantha K.
    McNally, Andrew
    Sucosky, Philippe
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2016, 4
  • [3] Bicuspid aortic valve hemodynamics does not promote remodeling in porcine aortic wall concavity
    Atkins, Samantha K.
    Moore, Alison N.
    Sucosky, Philippe
    [J]. WORLD JOURNAL OF CARDIOLOGY, 2016, 8 (01): : 89 - 97
  • [4] Etiology of bicuspid aortic valve disease: Focus on hemodynamics
    Atkins, Samantha K.
    Sucosky, Philippe
    [J]. WORLD JOURNAL OF CARDIOLOGY, 2014, 6 (12): : 1227 - 1233
  • [5] Bicuspid aortic valve hemodynamics induces abnormal medial remodeling in the convexity of porcine ascending aortas
    Atkins, Samantha K.
    Cao, Kai
    Rajamannan, Nalini M.
    Sucosky, Philippe
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2014, 13 (06) : 1209 - 1225
  • [6] Aortic Dilation in Bicuspid Aortic Valve Disease Flow Pattern Is a Major Contributor and Differs With Valve Fusion Type
    Bissell, Malenka M.
    Hess, Aaron T.
    Biasiolli, Luca
    Glaze, Steffan J.
    Loudon, Margaret
    Pitcher, Alex
    Davis, Anne
    Prendergast, Bernard
    Markl, Michael
    Barker, Alex J.
    Neubauer, Stefan
    Myerson, Saul G.
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (04) : 499 - 507
  • [7] Analysis of flow in a cone-and-plate apparatus with respect to spatial and temporal effects on endothelial cells
    Buschmann, MH
    Dieterich, P
    Adams, NA
    Schnittler, HJ
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2005, 89 (05) : 493 - 502
  • [8] Computational comparison of regional stress and deformation characteristics in tricuspid and bicuspid aortic valve leaflets
    Cao, K.
    Sucosky, P.
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2017, 33 (03)
  • [9] Cao K., 2015, World J. Cardiovasc. Dis, V5, P129, DOI DOI 10.4236/WJCD.2015.56016
  • [10] Simulations of morphotype-dependent hemodynamics in non-dilated bicuspid aortic valve aortas
    Cao, Kai
    Atkins, Samantha K.
    McNally, Andrew
    Liu, Janet
    Sucosky, Philippe
    [J]. JOURNAL OF BIOMECHANICS, 2017, 50 : 63 - 70