Stress analysis of a polyethylene acetabular component in the extreme flexion position-a finite element analysis

被引:0
|
作者
Promsang, Trai [1 ]
Wilairatana, Vajara [1 ]
Tangpornprasert, Pairat [2 ]
Virulsri, Chanyaphan [2 ]
Itiravivong, Pibul [1 ]
机构
[1] Chulalongkorn Univ, Fac Med, Dept Orthoped, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Dept Mech Engn, Fac Engn, Bangkok 10330, Thailand
关键词
Finite element analysis; impingement; polyethylene; stress; total hip replacement; TOTAL HIP-ARTHROPLASTY; IMPINGEMENT; MOTION; RANGE; DISLOCATION; CRACKING;
D O I
10.5372/1905-7415.0706.253
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Many factors cause impingement of the femoral neck and polyethylene liners. Impingements definitely increase the rate of polyethylene wear. This effect has been a major cause of revision hip surgery. Squatting and sitting cross-legged are specific sitting positions typically used by Asian people, including Thai. These types of positions may cause impingements and abnormal stress distributions, resulting in massive destruction of polyethylene liners. Objective: To analyze the effects of squatting and sitting in a cross-legged position in total hip replacement patients using finite element analysis. Methods: A three-dimensional finite element model was developed to study the effects of squatting and sitting in a cross-legged position. The study was divided into two parts. First, mean hip ranges of motion of sitting positions were analyzed. Second, hip ranges of motion at one standard deviation were also analyzed. Locations of the impingement area and stress distribution were demonstrated using finite element software. Results: Squatting and sitting cross-legged at one standard deviation obviously cause significant impingement at the superior part of the polyethylene liner. Maximum principal stresses are 103 MPa and 24.5 MPa in squatting and sitting cross-legged, respectively. There is no impingement when the mean hip ranges of motion are used. The distance between the neck and cup are 4.05 mm and 4.15 mm in squatting and sitting cross-legged, respectively. Conclusion: Squatting and sitting cross-legged can cause significant impingement in commonly used total hip replacements. Massive destruction of the prostheses can develop by the process of the impingement.
引用
收藏
页码:881 / 884
页数:4
相关论文
共 50 条
  • [21] The Effect of Knee Flexion on Length Changes and Stress Distribution of Ligaments: A Displacement Controlled Finite Element Analysis
    Xiao, Yang
    Feng, Xiaoreng
    Song, Yang
    Chen, Guo
    Liu, Fei
    Leung, Frankie K. L.
    Chen, Bin
    ORTHOPEDICS, 2021, 44 (01) : E61 - E67
  • [22] Finite element analysis of a novel design approach to resisting total hip dislocation
    Scifert, CF
    Brown, TD
    Lipman, JD
    CLINICAL BIOMECHANICS, 1999, 14 (10) : 697 - 703
  • [23] Nanoimprint Resist Stress Analysis under Low Temperature by Finite Element Analysis
    Sun, Hongwen
    Ma, Xiaochao
    Hu, Chenhui
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON ELECTROMECHANICAL CONTROL TECHNOLOGY AND TRANSPORTATION, 2015, 41 : 143 - 146
  • [24] Finite Element Analysis of Stress Distribution in Flat and Elevated-Rim Polyethylene Acetabutar Liners
    Kaku, Nobuhiro
    Tanaka, Ai
    Tagomori, Hiroaki
    Tsumura, Hiroshi
    CLINICS IN ORTHOPEDIC SURGERY, 2020, 12 (03) : 291 - 297
  • [25] The role of the transverse acetabular ligament for acetabular component orientation in total hip replacement AN ANALYSIS OF ACETABULAR COMPONENT POSITION AND RANGE OF MOVEMENT USING NAVIGATION SOFTWARE
    Kalteis, T.
    Sendtner, E.
    Beverland, D.
    Archbold, P. A.
    Hube, R.
    Schuster, T.
    Renkawitz, T.
    Grifka, J.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (08): : 1021 - 1026
  • [26] Finite Element Analysis for Bending Stress of Face-Gear
    Zhang Shuyan
    Lei Guangming
    Wang Minghai
    Guo Hui
    2009 INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION, VOL II, 2009, : 795 - +
  • [27] Finite element analysis and structural improvement of component with notches
    Huang, Ning
    Huang, Ming Hui
    Zhan, Li Hua
    PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION (ICMS2009), VOL 3, 2009, : 325 - 328
  • [28] Finite element analysis of posterior acetabular column plate and posterior acetabular wall prostheses in treating posterior acetabular fractures
    Huang, Guixiong
    Wan, Yizhou
    Chen, Kaifang
    Yin, Zhenchun
    Song, Qinghua
    Xu, Yi
    Guo, Xiaodong
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [29] Analysis and results of dissociation of the polyethylene liner in the Harris-Galante I acetabular component
    Saito, Shu
    Ryu, Junnosuke
    Seki, Masayuki
    Ishii, Takao
    Saigo, Kaichiro
    Mori, Sei
    JOURNAL OF ARTHROPLASTY, 2008, 23 (04) : 522 - 526
  • [30] Polyethylene sterilized without irradiation in a polished uncemented acetabular component - A clinical and radiographic analysis
    Crockarell, John R., Jr.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (06) : 911 - 915