Stress analysis of a polyethylene acetabular component in the extreme flexion position-a finite element analysis

被引:0
|
作者
Promsang, Trai [1 ]
Wilairatana, Vajara [1 ]
Tangpornprasert, Pairat [2 ]
Virulsri, Chanyaphan [2 ]
Itiravivong, Pibul [1 ]
机构
[1] Chulalongkorn Univ, Fac Med, Dept Orthoped, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Dept Mech Engn, Fac Engn, Bangkok 10330, Thailand
关键词
Finite element analysis; impingement; polyethylene; stress; total hip replacement; TOTAL HIP-ARTHROPLASTY; IMPINGEMENT; MOTION; RANGE; DISLOCATION; CRACKING;
D O I
10.5372/1905-7415.0706.253
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Many factors cause impingement of the femoral neck and polyethylene liners. Impingements definitely increase the rate of polyethylene wear. This effect has been a major cause of revision hip surgery. Squatting and sitting cross-legged are specific sitting positions typically used by Asian people, including Thai. These types of positions may cause impingements and abnormal stress distributions, resulting in massive destruction of polyethylene liners. Objective: To analyze the effects of squatting and sitting in a cross-legged position in total hip replacement patients using finite element analysis. Methods: A three-dimensional finite element model was developed to study the effects of squatting and sitting in a cross-legged position. The study was divided into two parts. First, mean hip ranges of motion of sitting positions were analyzed. Second, hip ranges of motion at one standard deviation were also analyzed. Locations of the impingement area and stress distribution were demonstrated using finite element software. Results: Squatting and sitting cross-legged at one standard deviation obviously cause significant impingement at the superior part of the polyethylene liner. Maximum principal stresses are 103 MPa and 24.5 MPa in squatting and sitting cross-legged, respectively. There is no impingement when the mean hip ranges of motion are used. The distance between the neck and cup are 4.05 mm and 4.15 mm in squatting and sitting cross-legged, respectively. Conclusion: Squatting and sitting cross-legged can cause significant impingement in commonly used total hip replacements. Massive destruction of the prostheses can develop by the process of the impingement.
引用
收藏
页码:881 / 884
页数:4
相关论文
共 50 条
  • [1] The Comparative Analysis of a Novel Acetabular Component Against Hemispherical Component in Case of Extensive Acetabular Bone Defects - A Study Of Finite Element Analysis
    Ma, Wenhui
    Zhang, Xuemin
    Zhang, Yingze
    INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2013, 10
  • [2] Effect of alveolar bone support on zygomatic implants in an extra-sinus position-a finite element analysis study
    Freedman, M.
    Ring, M.
    Stassen, L. F. A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (06) : 785 - 790
  • [3] Stress analysis of glenoid component in design of reverse shoulder prosthesis using finite element method
    Yang, Ching-Chieh
    Lu, Chun-Lin
    Wu, Chun-Hung
    Wu, Jiunn-Jer
    Huang, Teng-Le
    Chen, Rongshun
    Yeh, Meng-Kao
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (07) : 932 - 939
  • [4] Theoretical Implications of Periacetabular Osteotomy in Various Dysplastic Acetabular Cartilage Defects as Determined by Finite Element Analysis
    Xu, Meng
    Qu, Wenrui
    Wang, Yanbing
    Zhong, Lei
    Zhu, Zhe
    Li, Wei
    Zhao, Xin
    Wang, Jincheng
    Sun, Yu
    MEDICAL SCIENCE MONITOR, 2016, 22 : 5124 - 5130
  • [5] Does the optimal position of the acetabular fragment should be within the radiological normal range for all developmental dysplasia of the hip? A patient-specific finite element analysis
    Wang, Xuyi
    Peng, Jianping
    Li, De
    Zhang, Linlin
    Wang, Hui
    Jiang, Leisheng
    Chen, Xiaodong
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2016, 11
  • [6] Optimized design for a novel acetabular component with three wings. A study of finite element analysis
    Ma, Wenhui
    Zhang, Xuemin
    Wang, Jifang
    Zhang, Qi
    Chen, Wei
    Zhang, Yingze
    JOURNAL OF SURGICAL RESEARCH, 2013, 179 (01) : 78 - 86
  • [7] Finite element analysis of the effect of tibial osteotomy on the stress of polyethylene liner in total knee arthroplasty
    Sun, Lihui
    Han, Yu
    Jing, Zheng
    Li, Dongbo
    Liu, Jianguo
    Li, Dongsong
    JOURNAL OF ORTHOPAEDIC SURGERY, 2024, 32 (02)
  • [8] Combined Bone Ingrowth and Remodeling Around Uncemented Acetabular Component: A Multiscale Mechanobiology-Based Finite Element Analysis
    Mukherjee, Kaushik
    Gupta, Sanjay
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2017, 139 (09):
  • [9] Finite Element Modelling for Assessing Effect of Acetabular Component Orientation on the Basic Stress Path above Acetabular Dome
    Nie, Yong
    Pei, Fu-xing
    Li, Zong-ming
    ORTHOPAEDIC SURGERY, 2015, 7 (01) : 66 - 73
  • [10] The effect of malalignment on stresses in polyethylene component of total knee prostheses - a finite element analysis
    Liau, JJ
    Cheng, CK
    Huang, CH
    Lo, WH
    CLINICAL BIOMECHANICS, 2002, 17 (02) : 140 - 146