Evaluating metallic artefact of biodegradable magnesium-based implants in magnetic resonance imaging

被引:12
作者
Espiritu, Jonathan [1 ]
Berangi, Mostafa [2 ,3 ,4 ,5 ,6 ]
Yiannakou, Christina [7 ]
Silva, Eduarda [8 ]
Francischello, Roberto [9 ,10 ]
Kuehne, Andre [2 ]
Niendorf, Thoralf [2 ,3 ,4 ,5 ,6 ]
Koenneker, Soeren [3 ,4 ,5 ]
Willumeit-Romer, Regine [11 ]
Seitz, Jan-Marten [1 ]
机构
[1] Syntellix AG, Hannover, Germany
[2] MRI TOOLS GmbH, Berlin, Germany
[3] Charite Univ Med Berlin, Berlin, Germany
[4] Free Univ Berlin, Berlin, Germany
[5] Humboldt Univ, Berlin, Germany
[6] Max Delbrueck Ctr Mol Med, Berlin Ultrahigh Field Facil BUFF, Helmholtz Assoc, Berlin, Germany
[7] Hannover Med Sch, Hannover, Germany
[8] CNR, Inst Clin Physiol, Pisa, Italy
[9] Univ Pisa, Chem & Ind Chem Dept, Via Moruzzi 13, Pisa, Italy
[10] Fdn Toscana Gabriele Monasterio, Via Moruzzi 1, Pisa, Italy
[11] Helmholtz Zentrum Hereon, Inst Mat Res, Geesthacht, Germany
基金
欧盟地平线“2020”;
关键词
Magnetic resonance imaging; Magnesium; Biodegradable implants; Medical imaging; Translational medicine; TITANIUM; ALLOYS; MRI;
D O I
10.1016/j.bioactmat.2021.11.035
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnesium (Mg) implants have shown to cause image artefacts or distortions in magnetic resonance imaging (MRI). Yet, there is a lack of information on how the degradation of Mg-based implants influences the image quality of MRI examinations. In this study, Mg-based implants are analysed in vitro, ex vivo, and in the clinical setting for various magnetic field strengths with the aim to quantify metallic artefact behaviour. In vitro corroded Mg-based screws and a titanium (Ti) equivalent were imaged according to the ASTM F2119. Mg-based and Ti pins were also implanted into rat femurs for different time points and scanned to provide insights on the influence of soft and hard tissue on metallic artefact. Additionally, MRI data of patients with scaphoid fractures treated with CE-approved Mg-based compression screws (MAGNEZIX (R)) were analysed at various time points post-surgery. The artefact production of the Mg-based material decreased as implant material degraded in all settings. The worst-case imaging scenario was determined to be when the imaging plane was selected to be perpendicular to the implant axis. Moreover, the Mg-based implant outperformed the Ti equivalent in all experiments by producing lower metallic artefact (p < 0.05). This investigation demonstrates that Mg-based implants generate significantly lower metallic distortion in MRI when compared to Ti. Our positive findings suggest and support further research into the application of Mg-based implants including post-operative care facilitated by MRI monitoring of degradation kinetics and bone/tissue healing processes.
引用
收藏
页码:382 / 391
页数:10
相关论文
共 36 条
  • [21] Ludeke K M, 1985, Magn Reson Imaging, V3, P329, DOI 10.1016/0730-725X(85)90397-2
  • [22] Marcucci G, 2010, CLIN CASES MINER BON, V7, P51
  • [23] Bioabsorbable magnesium screw versus conventional titanium screw fixation for medial malleolar fractures
    May, Hasan
    Kati, Yusuf Alper
    Gumussuyu, Gurkan
    Emre, Tuluhan Yunus
    Unal, Melih
    Kose, Ozkan
    [J]. JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2020, 21 (01)
  • [24] The increasing role of muscle MRI to monitor changes over time in untreated and treated muscle diseases
    Nunez-Peralta, Claudia
    Alonso-Perez, Jorge
    Diaz-Manera, Jordi
    [J]. CURRENT OPINION IN NEUROLOGY, 2020, 33 (05) : 611 - 620
  • [25] Bioabsorbable magnesium versus standard titanium compression screws for fixation of distal metatarsal osteotomies-3 year results of a randomized clinical trial
    Plaass, Christian
    von Falck, Christian
    Ettinger, Sarah
    Sonnow, Lena
    Calderone, Franco
    Weizbauer, Andreas
    Reifenrath, Janin
    Claassen, Leif
    Waizy, Hazibullah
    Daniilidis, Kiriakos
    Stukenborg-Colsman, Christina
    Windhagen, Henning
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (02) : 321 - 327
  • [26] The effect of freeze-thawing on magnetic resonance imaging T2* of freshly harvested bovine patellar tendon
    Pownder, Sarah L.
    Shah, Parina H.
    Potter, Hollis G.
    Koff, Matthew F.
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2015, 5 (03) : 368 - 373
  • [27] Metal artefact reduction in MRI at both 1.5 and 3.0 T using slice encoding for metal artefact correction and view angle tilting
    Reichert, M.
    Ai, T.
    Morelli, J. N.
    Nittka, M.
    Attenberger, U.
    Runge, V. M.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1048)
  • [28] Composition of corrosion layers on a magnesium rare-earth alloy in simulated body fluids
    Rettig, Ralf
    Virtanen, Sannakaisa
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 88A (02) : 359 - 369
  • [29] Schulz KF, 2010, ANN INTERN MED, V152, P726, DOI 10.7326/0003-4819-152-11-201006010-00232
  • [30] Magnesium degradation products: Effects on tissue and human metabolism
    Seitz, J. -M.
    Eifler, R.
    Bach, Fr-W.
    Maier, H. J.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2014, 102 (10) : 3744 - 3753