ACQUISITION OF 3-D ARTERIAL GEOMETRIES AND INTEGRATION WITH COMPUTATIONAL FLUID DYNAMICS

被引:16
作者
Hammer, Steven [1 ]
Jeays, Adam [3 ]
Allan, Paul L. [2 ]
Hose, Rod [3 ]
Barber, David [3 ]
Easson, William J. [1 ]
Hoskins, Peter R.
机构
[1] Univ Edinburgh, Edinburgh, Midlothian, Scotland
[2] Royal Edinburgh Infirm, Dept Radiol, Edinburgh, Midlothian, Scotland
[3] Univ Sheffield, Sheffield, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
3-D; Artery; Computational fluid dynamics; Flow-field; Optical tracking; Segmentation; Ultrasound; Wall shear stress; WALL SHEAR-STRESS; NONPLANAR CAROTID BIFURCATION; CLINICAL ULTRASOUND SCANNER; ANATOMICAL FLOW PHANTOMS; FREEHAND 3D ULTRASOUND; VULNERABLE PLAQUES; DOPPLER ULTRASOUND; BLOOD-FLOW; VELOCITY; PRESSURE;
D O I
10.1016/j.ultrasmedbio.2009.06.1099
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A system for acquisition of 3-D arterial ultrasound geometries and integration with computational fluid dynamics (CFD) is described. The 3-D ultrasound is based on freehand B-mode imaging with positional information obtained using an optical tracking system. A processing chain was established, allowing acquisition of cardiac-gated 3-D data and segmentation of arterial geometries using a manual method and a semi-automated method, 3D meshing and CFD. The use of CFD allowed visualization of flow streamlines, 2-D velocity contours and 3-D wall shear stress. Three-dimensional positional accuracy was 0.17-1.8 mm, precision was 0.06-0.47 mm and volume accuracy was 4.4-15%. Patients with disease and volunteers were scanned, with data collection from one or more of the carotid bifurcation, femoral bifurcation and abdominal aorta. An initial comparison between a manual segmentation method and a semi-automated method suggested some advantages to the semi-automated method, including reduced operator time and the production of smooth surfaces suitable for CFD, but at the expense of over-smoothing in the diseased region. There were considerable difficulties with artefacts and poor image quality, resulting in 3-D geometry data that was unsuitable for CFD. These artefacts were exacerbated in disease, which may mean that future effort, in the integration of 3-D arterial geometry and CFD for clinical use, may best be served using alternative 3-D imaging modalities such as magnetic resonance imaging and computed tomography. (E-mail: P.Hoskins@ed.ac.uk) (C) 2009 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:2069 / 2083
页数:15
相关论文
共 51 条
[41]   Measurement of hemodynamics in human carotid artery using ultrasound and computational fluid dynamics [J].
Starmans-Kool, MJ ;
Stanton, AV ;
Zhao, SZ ;
Xu, XY ;
Thom, SAM ;
Hughes, AD .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 92 (03) :957-961
[42]   Computational modeling of arterial biomechanics: Insights into pathogenesis and treatment of vascular disease [J].
Steinman, DA ;
Vorp, DA ;
Ethier, CR .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (05) :1118-1128
[43]   SPIRAL LAMINAR-FLOW IN ARTERIES [J].
STONEBRIDGE, PA ;
BROPHY, CM .
LANCET, 1991, 338 (8779) :1360-1361
[44]   Experimental and computational methods in cardiovascular fluid mechanics [J].
Taylor, CA ;
Draney, MT .
ANNUAL REVIEW OF FLUID MECHANICS, 2004, 36 :197-231
[45]   Noninvasive simultaneous assessment of wall shear rate and wall distension in carotid arteries [J].
Tortoli, Piero ;
Morganti, Tiziano ;
Bambi, GlAcomo ;
Palombo, Carlo ;
Ramnarine, Kumar V. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (11) :1661-1670
[46]   High-definition freehand 3-D ultrasound [J].
Treece, GM ;
Gee, AH ;
Prager, RW ;
Cash, CJC ;
Berman, LH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (04) :529-546
[47]   Correction of probe pressure artifacts in freehand 3D ultrasound [J].
Treece, GM ;
Prager, RW ;
Gee, AH ;
Berman, L .
MEDICAL IMAGE ANALYSIS, 2002, 6 (03) :199-214
[48]   A framework for evaluating image segmentation algorithms [J].
Udupa, JK ;
LeBlanc, VR ;
Ying, ZG ;
Imielinska, C ;
Schmidt, H ;
Currie, LM ;
Hirsch, BE ;
Woodburn, J .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2006, 30 (02) :75-87
[49]   Anatomical flow phantoms of the nonplanar carotid bifurcation, part I: Computer-aided design and fabrication [J].
Watts, D. M. ;
Sutcliffe, C. J. ;
Morgan, R. H. ;
Meagher, S. ;
Wardlaw, J. ;
Connell, M. ;
Bastin, M. E. ;
Marshall, I. ;
Ramnarine, K. V. ;
Hoskins, P. R. ;
Black, R. A. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (02) :296-302
[50]   METHOD FOR THE CALCULATION OF VELOCITY, RATE OF FLOW AND VISCOUS DRAG IN ARTERIES WHEN THE PRESSURE GRADIENT IS KNOWN [J].
WOMERSLEY, JR .
JOURNAL OF PHYSIOLOGY-LONDON, 1955, 127 (03) :553-563