ACQUISITION OF 3-D ARTERIAL GEOMETRIES AND INTEGRATION WITH COMPUTATIONAL FLUID DYNAMICS

被引:16
作者
Hammer, Steven [1 ]
Jeays, Adam [3 ]
Allan, Paul L. [2 ]
Hose, Rod [3 ]
Barber, David [3 ]
Easson, William J. [1 ]
Hoskins, Peter R.
机构
[1] Univ Edinburgh, Edinburgh, Midlothian, Scotland
[2] Royal Edinburgh Infirm, Dept Radiol, Edinburgh, Midlothian, Scotland
[3] Univ Sheffield, Sheffield, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
3-D; Artery; Computational fluid dynamics; Flow-field; Optical tracking; Segmentation; Ultrasound; Wall shear stress; WALL SHEAR-STRESS; NONPLANAR CAROTID BIFURCATION; CLINICAL ULTRASOUND SCANNER; ANATOMICAL FLOW PHANTOMS; FREEHAND 3D ULTRASOUND; VULNERABLE PLAQUES; DOPPLER ULTRASOUND; BLOOD-FLOW; VELOCITY; PRESSURE;
D O I
10.1016/j.ultrasmedbio.2009.06.1099
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A system for acquisition of 3-D arterial ultrasound geometries and integration with computational fluid dynamics (CFD) is described. The 3-D ultrasound is based on freehand B-mode imaging with positional information obtained using an optical tracking system. A processing chain was established, allowing acquisition of cardiac-gated 3-D data and segmentation of arterial geometries using a manual method and a semi-automated method, 3D meshing and CFD. The use of CFD allowed visualization of flow streamlines, 2-D velocity contours and 3-D wall shear stress. Three-dimensional positional accuracy was 0.17-1.8 mm, precision was 0.06-0.47 mm and volume accuracy was 4.4-15%. Patients with disease and volunteers were scanned, with data collection from one or more of the carotid bifurcation, femoral bifurcation and abdominal aorta. An initial comparison between a manual segmentation method and a semi-automated method suggested some advantages to the semi-automated method, including reduced operator time and the production of smooth surfaces suitable for CFD, but at the expense of over-smoothing in the diseased region. There were considerable difficulties with artefacts and poor image quality, resulting in 3-D geometry data that was unsuitable for CFD. These artefacts were exacerbated in disease, which may mean that future effort, in the integration of 3-D arterial geometry and CFD for clinical use, may best be served using alternative 3-D imaging modalities such as magnetic resonance imaging and computed tomography. (E-mail: P.Hoskins@ed.ac.uk) (C) 2009 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:2069 / 2083
页数:15
相关论文
共 51 条
[21]  
Hoskins P.R., 1994, EUROPEAN J ULTRASOUN, V1, P159
[22]   B-MODE compound imaging in mice [J].
Hoskins, PR ;
Anderson, T ;
Meagher, S ;
MacGillivray, TJ ;
Sharp, M ;
McDicken, WN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (01) :29-32
[23]   Peak velocity estimation in arterial stenosis models using colour vector Doppler [J].
Hoskins, PR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06) :889-897
[24]   PULSATILE VELOCITY DISTRIBUTION AND WALL SHEAR RATE MEASUREMENT USING PULSED DOPPLER ULTRASOUND [J].
HUGHES, PE ;
HOW, TV .
JOURNAL OF BIOMECHANICS, 1994, 27 (01) :103-110
[25]   THE INFLUENCE OF ULTRASOUND SCANNER BEAM WIDTH ON FEMUR LENGTH MEASUREMENTS [J].
JAGO, JR ;
WHITTINGHAM, TA ;
HESLOP, R .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (08) :699-703
[26]   Characterisation of the haemodynamics of the superior mesenteric artery [J].
Jeays, A. D. ;
Lawford, P. V. ;
Gillott, R. ;
Spencer, P. ;
Barber, D. C. ;
Bardhan, K. D. ;
Hose, D. R. .
JOURNAL OF BIOMECHANICS, 2007, 40 (09) :1916-1926
[27]   Characterization of carotid artery plaques using real-time compound B-mode ultrasound [J].
Kern, R ;
Szabo, K ;
Hennerici, M ;
Meairs, S .
STROKE, 2004, 35 (04) :870-875
[28]   MRI measurement of wall shear stress vectors in bifurcation models and comparison with CFD predictions [J].
Köhler, U ;
Marshall, I ;
Robertson, MB ;
Long, Q ;
Xu, XY ;
Hoskins, PR .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) :563-573
[29]   Ultrasound image-based computer model of a common carotid artery with a plaque [J].
Lee, KW ;
Wood, NB ;
Xu, XY .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (10) :823-840
[30]   Numerical analysis of pulsatile blood flow and vessel wall mechanics in different degrees of stenoses [J].
Li, M. X. ;
Beech-Brandt, J. J. ;
John, L. R. ;
Hoskins, P. R. ;
Easson, W. J. .
JOURNAL OF BIOMECHANICS, 2007, 40 (16) :3715-3724