ACQUISITION OF 3-D ARTERIAL GEOMETRIES AND INTEGRATION WITH COMPUTATIONAL FLUID DYNAMICS

被引:16
作者
Hammer, Steven [1 ]
Jeays, Adam [3 ]
Allan, Paul L. [2 ]
Hose, Rod [3 ]
Barber, David [3 ]
Easson, William J. [1 ]
Hoskins, Peter R.
机构
[1] Univ Edinburgh, Edinburgh, Midlothian, Scotland
[2] Royal Edinburgh Infirm, Dept Radiol, Edinburgh, Midlothian, Scotland
[3] Univ Sheffield, Sheffield, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
3-D; Artery; Computational fluid dynamics; Flow-field; Optical tracking; Segmentation; Ultrasound; Wall shear stress; WALL SHEAR-STRESS; NONPLANAR CAROTID BIFURCATION; CLINICAL ULTRASOUND SCANNER; ANATOMICAL FLOW PHANTOMS; FREEHAND 3D ULTRASOUND; VULNERABLE PLAQUES; DOPPLER ULTRASOUND; BLOOD-FLOW; VELOCITY; PRESSURE;
D O I
10.1016/j.ultrasmedbio.2009.06.1099
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A system for acquisition of 3-D arterial ultrasound geometries and integration with computational fluid dynamics (CFD) is described. The 3-D ultrasound is based on freehand B-mode imaging with positional information obtained using an optical tracking system. A processing chain was established, allowing acquisition of cardiac-gated 3-D data and segmentation of arterial geometries using a manual method and a semi-automated method, 3D meshing and CFD. The use of CFD allowed visualization of flow streamlines, 2-D velocity contours and 3-D wall shear stress. Three-dimensional positional accuracy was 0.17-1.8 mm, precision was 0.06-0.47 mm and volume accuracy was 4.4-15%. Patients with disease and volunteers were scanned, with data collection from one or more of the carotid bifurcation, femoral bifurcation and abdominal aorta. An initial comparison between a manual segmentation method and a semi-automated method suggested some advantages to the semi-automated method, including reduced operator time and the production of smooth surfaces suitable for CFD, but at the expense of over-smoothing in the diseased region. There were considerable difficulties with artefacts and poor image quality, resulting in 3-D geometry data that was unsuitable for CFD. These artefacts were exacerbated in disease, which may mean that future effort, in the integration of 3-D arterial geometry and CFD for clinical use, may best be served using alternative 3-D imaging modalities such as magnetic resonance imaging and computed tomography. (E-mail: P.Hoskins@ed.ac.uk) (C) 2009 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:2069 / 2083
页数:15
相关论文
共 51 条
[11]   ATHEROMA AND ARTERIAL WALL SHEAR - OBSERVATION, CORRELATION AND PROPOSAL OF A SHEAR DEPENDENT MASS TRANSFER MECHANISM FOR ALTHEROGENESIS [J].
CARO, CG ;
FITZGERA.JM ;
SCHROTER, RC .
PROCEEDINGS OF THE ROYAL SOCIETY SERIES B-BIOLOGICAL SCIENCES, 1971, 177 (1046) :109-+
[12]  
CARO CG, 1978, MECH CIRCULATION, P46
[13]  
DOUGLAS JF, 2001, FLUID MECH, P11
[14]   Shear rate estimation using a clinical ultrasound scanner [J].
Forsberg, F ;
Morvay, Z ;
Rawool, NM ;
Deane, CR ;
Needleman, L .
JOURNAL OF ULTRASOUND IN MEDICINE, 2000, 19 (05) :323-327
[15]   Time-resolved magnetic resonance angiography and flow-sensitive 4-dimensional magnetic resonance imaging at 3 Tesla for blood flow and wall shear stress analysis [J].
Frydrychowicz, Alex ;
Berger, Alexander ;
Russe, Maximilan F. ;
Stalder, Aurelien F. ;
Harloff, Andreas ;
Dittrich, Sven ;
Hennig, Juergen ;
Langer, Mathias ;
Markl, Michael .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 136 (02) :400-407
[16]   Operator dependence of 3-D ultrasound-based computational fluid dynamics for the carotid bifurcation [J].
Glor, FP ;
Ariff, B ;
Hughes, AD ;
Verdonck, PR ;
McG, SA ;
Barratt, DC ;
Xu, XY .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (04) :451-456
[17]   Carotid geometry reconstruction: a comparison between MRI and ultrasound [J].
Glor, FP ;
Ariff, B ;
Crowe, LA ;
Hughes, AD ;
Cheong, PL ;
Thom, SAM ;
Verdonck, PR ;
Firmin, DN ;
Barratt, DC ;
Xu, XY .
MEDICAL PHYSICS, 2003, 30 (12) :3251-3261
[18]   Image-based carotid flow reconstruction: a comparison between MRI and ultrasound [J].
Glor, FP ;
Ariff, B ;
Hughes, AD ;
Crowe, LA ;
Verdonck, PR ;
Barratt, DC ;
Thom, SAM ;
Firmin, DN ;
Xu, XY .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (06) :1495-1509
[19]   Carotid artery stenosis: Gray-scale and Doppler US diagnosis - Society of Radiologists in Ultrasound consensus conference [J].
Grant, EG ;
Benson, CB ;
Moneta, GL ;
Alexandrov, AV ;
Baker, JD ;
Bluth, EI ;
Carroll, BA ;
Eliasziw, M ;
Gocke, J ;
Hertzberg, BS ;
Katanick, S ;
Needleman, L ;
Pellerito, J ;
Polak, JF ;
Rholl, KS ;
Wooster, DL ;
Zierler, E .
RADIOLOGY, 2003, 229 (02) :340-346
[20]  
HAMMER S, 2009, THESIS U EDINBURGH