Temperature dependence of the Al2O3:C response in medical luminescence dosimetry

被引:26
作者
Edmund, Jens M. [1 ]
Andersen, Claus E. [1 ]
机构
[1] Riso Natl Lab, Radiat Res Dept, DK-4000 Roskilde, Denmark
关键词
optically stimulated luminescence; radioluminescence; temperature; Al2O3 : C; medical dosimetry;
D O I
10.1016/j.radmeas.2006.11.006
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Over the last years, attention has been given to applications of Al2O3:C in space and medical dosimetry. One such application is in vivo dose verification in radiotherapy of cancer patients and here we investigate the temperature effects on the radioluminescence (RL) and optically stimulated luminescence (OSL) signals in the room-to-body temperature region. We found that the OSL response changes with both irradiation and stimulation temperatures as well as the OSL integration time. We conclude that temperature effects on the OSL response can be removed by integration if the irradiation temperature is not varied. The RL response only depends on the irradiation temperature. We recommend that calibration should be carried out at the same irradiation temperature at which the measurement is performed (i.e. at body temperature for in vivo measurements). The overall change in the integrated OSL and RL signals with irradiation and stimulation temperature covers an interval from -0.2% to 0.6% per degrees C. This indicates the correction factor one must take into account when performing luminescence dosimetry at different temperatures. The same effects were observed regardless of crystal type, test doses and stimulation and detection wavelengths. The reported temperature dependence seems to be a general property of Al2O3:C. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:177 / 189
页数:13
相关论文
共 37 条
[1]  
AGERSNAP NL, 1999, DOSIMETRY BASED THER
[2]  
AgersnapLarsen NB, 1999, RADIAT PROT DOSIM, V84, P87
[3]  
AKSELROD MS, 1990, RADIAT PROT DOSIM, V32, P15
[4]  
AKSELROD MS, 1993, RADIAT PROT DOSIM, V47, P159
[5]   Optically stimulated luminescence of Al2O3 [J].
Akselrod, MS ;
Lucas, AC ;
Polf, JC ;
McKeever, SWS .
RADIATION MEASUREMENTS, 1998, 29 (3-4) :391-399
[6]   An algorithm for real-time dosimetry in intensity-modulated radiation therapy using the radioluminescence signal from Al2O3:C [J].
Andersen, C. E. ;
Marckmann, C. J. ;
Aznar, M. C. ;
Botter-Jensen, L. ;
Kjaer-Kristoffersen, F. ;
Medin, J. .
RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) :7-13
[7]   A mini X-ray generator as an alternative to a 90Sr/90Y beta source in luminescence dating [J].
Andersen, CE ;
Botter-Jensen, L ;
Murray, AS .
RADIATION MEASUREMENTS, 2003, 37 (4-5) :557-561
[8]  
ANDERSEN CE, 2003, IAEA VIENNA, V2, P353
[9]   Real-time optical-fibre luminescence dosimetry for radiotherapy:: physical characteristics and applications in photon beams [J].
Aznar, MC ;
Andersen, CE ;
Botter-Jensen, L ;
Bäck, SÅJ ;
Mattsson, S ;
Kjær-Kristoffersen, F ;
Medin, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (09) :1655-1669
[10]   In vivo absorbed dose measurements in mammography using a new real-time luminescence technique [J].
Aznar, MC ;
Hemdal, B ;
Medin, J ;
Marckmann, CJ ;
Andersen, CE ;
Botter-Jensen, L ;
Andersson, I ;
Mattsson, S .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (928) :328-334