Bioactive paper platform for detection of hydrogen peroxide in milk

被引:38
作者
Lima, Liliane Spazzapam [1 ]
Rossini, Eduardo Luiz [1 ]
Pezza, Leonardo [1 ]
Pezza, Helena Redigolo [1 ]
机构
[1] UNESP Sao Paulo State Univ, Inst Quim, R Prof Francisco Degni 55,POB 355, BR-14800900 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Hydrogen peroxide; Milk adulteration; Bioactive paper platform; Digital image; QUANTIFICATION; SAMPLES; DEVICE; FOOD;
D O I
10.1016/j.saa.2019.117774
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This paper describes the development and application of a paper-based analytical device (mu PAD) for the determination of hydrogen peroxide, an important adulterant in milk. The method employs the reaction between hydrogen peroxide and guaiacol, catalyzed by peroxidase, producing a red product, which is then quantified by digital imaging. Experimental design methodology was used to optimize the experimental conditions. The linear concentration range was from 12.5 x 10(-4) to 150 x 10(-4) mol L-1, resulting in the regression equation AB = 0.02466 (+/- 0.00192) + 17.053 (+/- 0.750) C, with an excellent correlation coefficient (r = 0.986). The relative standard deviations obtained were 1.1 and 1.3% (intra-day), and 4.8 and 2.9% (inter-day), for 25.0 x 10(-4) and 100 x 10(-4) mol L-1 of hydrogen peroxide, respectively. The limits of detection and quantification were 3.54 x 10(-4) and 11.8 x 10(-4) mol L-1, respectively, with standard deviation of the blank of 0.002012. The proposed method was successfully applied for the determination of peroxide in milk samples, with recoveries between 92.2 and 109%. The proposed device constitutes a valuable analytical tool for the identification of hydrogen peroxide adulteration and offers advantages including low cost, simplicity, portability, and no (or minimal) requirement for sample pretreatment. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:6
相关论文
共 36 条
[1]   Fluorometric determination of hydrogen peroxide in milk by using a Fenton reaction system [J].
Abbas, M. E. ;
Luo, Wei ;
Zhu, Lihua ;
Zou, Jing ;
Tang, Heqing .
FOOD CHEMISTRY, 2010, 120 (01) :327-331
[2]   A simple and cost-effective method, as an appropriate alternative for visible spectrophotometry: development of a dopamine biosensor [J].
Abbaspour, Abdolkarim ;
Khajehzadeh, Abdolreza ;
Ghaffarinejad, Ali .
ANALYST, 2009, 134 (08) :1692-1698
[3]  
Abrantes M. R., 2014, Revista do Instituto Adolfo Lutz, V73, P244, DOI 10.18241/0073-98552014731611
[4]   A colorimetric paper-based analytical device coupled with hollow fiber membrane liquid phase microextraction (HF-LPME) for highly sensitive detection of hexavalent chromium in water samples [J].
Alahmad, Waleed ;
Tungkijanansin, Nuttanee ;
Kaneta, Takashi ;
Varanusupakul, Pakorn .
TALANTA, 2018, 190 :78-84
[5]  
Basset J., 1981, VOGEL ANALISE INORGA, P263
[6]  
Brito M.A., EMBRAPA COMPOSICAO
[7]   High throughput screening of protein formulation stability: Practical considerations [J].
Capelle, Martinus A. H. ;
Gurny, Robert ;
Arvinte, Tudor .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2007, 65 (02) :131-148
[8]  
Cardoso TMG, 2015, ANAL METHODS-UK, V7, P7311, DOI [10.1039/c5ay00466g, 10.1039/C5AY00466G]
[9]   Biodefense properties of milk: The role of antimicrobial proteins and peptides [J].
Clare, DA ;
Catignani, GL ;
Swaisgood, HE .
CURRENT PHARMACEUTICAL DESIGN, 2003, 9 (16) :1239-1255
[10]   Salivary diagnostics on paper microfluidic devices and their use as wearable sensors for glucose monitoring [J].
de Castro, Lucas F. ;
de Freitas, Soraia V. ;
Duarte, Lucas C. ;
de Souza, Joao Antonio C. ;
Paixao, Thiago R. L. C. ;
Coltro, Wendell K. T. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (19) :4919-4928