Indoor air quality and occupants' ventilation habits in China: Seasonal measurement and long-term monitoring

被引:78
作者
Liu, Junjie [1 ]
Dai, Xilei [1 ]
Li, Xiangdong [1 ]
Jia, Susu [1 ]
Pei, Jingjing [1 ]
Sun, Yuexia [1 ]
Lai, Dayi [1 ]
Shen, Xiong [1 ]
Sun, Hejiang [1 ]
Yin, Haiguo [2 ]
Huang, Kailiang [3 ]
Tan, Hongwei [4 ]
Gao, Yao [5 ]
Jian, Yiwen [6 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin Key Lab Indoor Air Environm Qual Control, Tianjin 300072, Peoples R China
[2] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian 710055, Shaanxi, Peoples R China
[3] Shenyang Jianzhu Univ, Dept Municipal & Environm Engn, Shenyang 110168, Liaoning, Peoples R China
[4] Tongji Univ, Sch Mech Engn, Siping Rd 1239, Shanghai 200092, Peoples R China
[5] Shenzhen Inst Bldg Res Co Ltd, Shenzhen 518049, Peoples R China
[6] Beijing Univ Technol, Coll Architecture & Civil Engn, Beijing 100124, Peoples R China
关键词
PM2.5; CO2; Formaldehyde; Ventilation habits; RESIDENTIAL HOMES; HONG-KONG; INDOOR/OUTDOOR RELATIONSHIPS; FORMALDEHYDE EXPOSURE; RISK-ASSESSMENT; CANCER-RISK; PM2.5; URBAN; POLLUTANTS; BUILDINGS;
D O I
10.1016/j.buildenv.2018.06.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is very important to know the current level of indoor pollution and occupants' ventilation habits. With this aim, this study presents an investigative project that covered five climate zones in China. The project consisted of two parts: long-term monitoring and seasonal measurements. For the long-term monitoring, we installed indoor air quality (IAQ) sensors, window state sensors, and mechanical ventilation sensors inside homes. In regard to IAQ, The median indoor 24-h averaged PM2.5 concentration ranged from 18 to 49 mu g/m(3). The indoor and outdoor 24-h averaged PM2.5 concentrations were similar for most of the regions. The 24-h averaged indoor CO2 concentrations were lower than 1000 ppm for all regions in all four seasons. Northern China usually had higher indoor CO2 concentrations than did southern China. In regard to occupants' behavior, in naturally ventilated homes, both the window-opening probability and open-window duration per day increased from the north to the south of China in winter. According to the example of mechanically ventilated Apartments, where pressure sensors were used to monitor the relative pressure at the air outlet of a mechanical ventilation system, the occupants used the ventilation system mainly in winter and spring. For the seasonal investigation, indoor formaldehyde concentrations in 224 homes were measured in four seasons (sampling time: 20 min). In summer, the indoor formaldehyde concentration reached its peak for the year, with about 35% of homes having concentrations larger than 100 mu g/m(3) under closed conditions (doors and windows have been closed for more than 12 h).
引用
收藏
页码:119 / 129
页数:11
相关论文
共 44 条
[1]  
ABBEY DE, 1995, J EXPO ANAL ENV EPID, V5, P137
[2]  
[Anonymous], 2002, 188832002 GBT CHIN N
[3]  
[Anonymous], 2012, 1522012 QXT
[4]  
[Anonymous], 2015, MOD PREV MED
[5]  
[Anonymous], 2014, 1820422014 GBT CHIN
[6]  
[Anonymous], 2014, HEALTH-LONDON
[7]  
[Anonymous], 2017, CHIN STAT YB 2017
[8]   Indoor air quality in homes, offices and restaurants in Korean urban areas - Indoor/outdoor relationships [J].
Baek, SO ;
Kim, YS ;
Perry, R .
ATMOSPHERIC ENVIRONMENT, 1997, 31 (04) :529-544
[9]   Indoor/outdoor relationships for PM2.5 and associated carbonaceous pollutants at residential homes in Hong Kong -: case study [J].
Cao, JJ ;
Lee, SC ;
Chow, JC ;
Cheng, Y ;
Ho, KF ;
Fung, K ;
Liu, SX ;
Watson, JG .
INDOOR AIR, 2005, 15 (03) :197-204
[10]   Air infiltration rates in the bedrooms of 202 residences and estimated parametric infiltration rate distribution in Guangzhou, China [J].
Cheng, Pok Lun ;
Li, Xiaofeng .
ENERGY AND BUILDINGS, 2018, 164 :219-225