A laser interferometer accelerometer for vibration sensitive cryogenic experiments

被引:7
|
作者
Bajpai, R. [1 ]
Tomaru, T. [2 ]
Yamamoto, K. [3 ]
Ushiba, T. [4 ]
Kimura, N. [4 ]
Suzuki, T. [5 ]
Yamada, T. [6 ]
Honda, T. [6 ]
机构
[1] Grad Univ Adv Studies, Sch High Energy Accelerator Sci, Dept Accelerator Sci, High Energy Accelerator Res Org KEK, Tsukuba, Ibaraki 3050801, Japan
[2] Natl Astron Observ Japan, 2 Chome 21-1 Osawa, Mitaka, Tokyo 1818588, Japan
[3] Univ Toyama, 3190 Gofuku, Toyama 9308555, Japan
[4] Univ Tokyo, Inst Cosm Ray Res, Kamioka Observ, Higashimozumi 238, Gifu 5061205, Japan
[5] Univ Tokyo, Inst Cosm Ray Res, Kashiwanoha 5-1-5, Kashiwa, Chiba 2778582, Japan
[6] High Energy Accelerator Res Org, 1-1 Oho, Tsukuba, Ibaraki 3050801, Japan
基金
新加坡国家研究基金会;
关键词
vibration; cryogenics; accelerometer; low-temperature sensors; gravitational wave detector;
D O I
10.1088/1361-6501/ac6d46
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Monitoring motion originating from ultra low-temperature cooling systems like cryocoolers is important for vibration sensitive cryogenic experiments like KAGRA. Since no high sensitivity commercial cryogenic accelerometers are available, we developed a compact self-calibrating accelerometer with a Michelson interferometer readout for cryogenic use. Change in calibration factor and drop in interferometer output originating from temperature drop were the main concerns which were tackled. Sensitivity of 3.38 x 10(-11) m/root Hz at 1 Hz was achieved at 300 K. The accelerometer was tested inside the KAGRA cryostat; showed stable operation down to 12 K in 0.1-100 Hz band with only 1% visibility drop. Our accelerometer can be employed in low vibration cryogenic environment for a multitude of applications.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Measurement of basilar membrane vibration using a scanning laser interferometer
    Ren, TY
    Zou, Y
    Zheng, JF
    Nuttall, AL
    Porsov, E
    Mattews, S
    BIOPHYSICS OF THE COCHLEA: FROM MOLECULES TO MODELS, 2003, : 211 - 219
  • [42] TRIPLE-PENDULUM VIBRATION ISOLATION SYSTEM FOR A LASER INTERFEROMETER
    TSUBONO, K
    ARAYA, A
    KAWABE, K
    MORIWAKI, S
    MIO, N
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (08): : 2237 - 2240
  • [43] Recording depth of the heterodyne laser interferometer for cochlear vibration measurement
    Ren, TY
    Nuttall, AL
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2001, 109 (02): : 826 - 829
  • [44] Application of laser heterodyne interferometer in solid rocket motor vibration
    Huo, Lei
    Zeng, Xiao-Dong
    Liu, Bing
    Guti Huojian Jishu/Journal of Solid Rocket Technology, 2012, 35 (01): : 139 - 142
  • [45] Experiments with an 834 m2 ring laser interferometer
    Hurst, R. B.
    Stedman, G. E.
    Schreiber, K. U.
    Thirkettle, R. J.
    Graham, R. D.
    Rabeendran, N.
    Wells, J-P. R.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (11)
  • [46] Lithium atom interferometer using laser diffraction: description and experiments
    A. Miffre
    M. Jacquey
    M. Büchner
    G. Trénec
    J. Vigué
    The European Physical Journal D - Atomic, Molecular, Optical and Plasma Physics, 2005, 33 : 99 - 112
  • [47] LASER OPTICS EXPERIMENTS WITH GLASS PLATES AND A MODIFIED JAMIN INTERFEROMETER
    WOOLSEY, GA
    AMERICAN JOURNAL OF PHYSICS, 1973, 41 (02) : 255 - 259
  • [48] Lithium atom interferometer using laser diffraction:: description and experiments
    Miffre, A
    Jacquey, M
    Büchner, M
    Trénec, G
    Vigué, J
    EUROPEAN PHYSICAL JOURNAL D, 2005, 33 (01): : 99 - 112
  • [49] Performance of a Cryogenic Michelson Interferometer
    Lagueux, Philippe
    Chamberland, Martin
    Marcotte, Frederick
    Villemaire, Andre
    Duval, Marc
    Genest, Jerome
    Carter, Adriaan
    ADVANCED OPTICAL AND MECHANICAL TECHNOLOGIES IN TELESCOPES AND INSTRUMENTATION, PTS 1-3, 2008, 7018
  • [50] ACOUSTICAL INTERFEROMETER FOR CRYOGENIC LIQUIDS
    LEONARD, RW
    SEGUIN, H
    IMAI, JS
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1966, 40 (05): : 1268 - &