Use of Neutron Scintillation Detectors as a Substitute for Helium-3 Counters in Radiation Monitors

被引:8
|
作者
Ryabeva, E. V. [1 ]
Kadilin, V. V. [1 ]
Idalov, V. A. [1 ]
机构
[1] Natl Res Nucl Univ, MEPhI, Moscow, Russia
关键词
Gamma rays - Neutrons - Efficiency - Neutron detectors - Neutron irradiation - Scintillation - Helium;
D O I
10.1007/s10512-019-00583-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The purpose of this work is to analyze the use of detecting materials in radiation monitors as well as the replacement of widely used H-3-based neutron counters by neutron-detection scintillation technology. The replacement of helium counters is a consequence of two factors: the lack of He-3 and widespread use of He-3-based counters in safety equipment, such as volumetric neutron detectors. Selection criteria for evaluating promising technologies are used in this work, specifically, high absolute neutron detection efficiency - efficiency at least 1.5 counts in 1 sec in detecting 1 ng Cf-252 at distance of 2 m in a 20 mm thick moderator and low sensitivity to gamma-ray detection - gamma-ray detection efficiency not exceeding 10(-6) with irradiation by a 0.1 mu Sv/h gamma-ray source. Since they can have a large sensitive area and high resolution, scintillation detectors are now being proposed as alternatives to helium counters. But it is necessary to find an optimal scintillator possessing simultaneously low sensitivity to gamma-radiation and to choose an optimal method of measuring information. Promising neutron detection technologies based on the glasses Li2OSiO2:Ce3+, LiF/ZnS(Ag+), Li6Gd(BO3)(3):Ce, Cs2LiYCl6(Ce) (CLYC) as well as EJ-254 boron-doped plastic are examined from the standpoint of the posed problems.
引用
收藏
页码:51 / 55
页数:5
相关论文
共 50 条
  • [1] Use of Neutron Scintillation Detectors as a Substitute for Helium-3 Counters in Radiation Monitors
    E. V. Ryabeva
    V. V. Kadilin
    V. A. Idalov
    Atomic Energy, 2019, 127 : 51 - 55
  • [2] Alternatives to Helium-3 for Neutron Multiplicity Counters
    Lintereur, Azaree T.
    Ely, James H.
    Kouzes, Richard T.
    Siciliano, Edward R.
    Swinhoe, Martyn T.
    Woodring, Mitchell L.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 547 - 553
  • [3] Large Area Portable Neutron Detectors Helium-3 Alternatives
    Workman, Herschel
    Kline, Craig
    Bell, Zane
    Diawara, Yacouba
    2012 IEEE INTERNATIONAL CONFERENCE ON TECHNOLOGIES FOR HOMELAND SECURITY, 2012, : 435 - 438
  • [4] Alternatives for Helium-3 in Multiplicity Counters
    Ely, James H.
    Siciliano, Edward R.
    Lintereur, Azaree T.
    Swinhoe, Martyn T.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 510 - 514
  • [5] Efficiency of composite boron nitride neutron detectors in comparison with helium-3 detectors
    Uher, J.
    Pospisil, S.
    Linhart, V.
    Schieber, M.
    APPLIED PHYSICS LETTERS, 2007, 90 (12)
  • [6] HIGH TEMPERATURE HELIUM-3 DETECTORS
    MYERS, JE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1967, NS14 (01) : 416 - &
  • [7] SEALED HELIUM-3 GAS SCINTILLATION COUNTER
    BALDIN, SA
    MAKAROV, YA
    SOKOLOV, AD
    SHUVALOV, GI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1967, (05): : 1138 - &
  • [8] Two-channel high-pressure helium-3 scintillation neutron detector
    Arodzero, A
    Bolozdynya, A
    Bolotnikov, A
    Proctor, A
    Richards, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (02) : 322 - 327
  • [9] Two-channel high-pressure helium-3 scintillation neutron detector
    Arodzero, A
    Bolozdynya, A
    Bolotnikov, A
    Proctor, A
    Richards, J
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 687 - 691
  • [10] Towards helium-3 neutron polarizers
    Inst Laue Langevin, Grenoble, France
    Phys B Condens Matter, (935-938):