Characterization of Microchamber Arrays for Targeted Drug Delivery
被引:0
作者:
Hao, Yang
论文数: 0引用数: 0
h-index: 0
机构:
Queen Mary Univ London, Sch Elect Engn & Comp Sci, London, EnglandQueen Mary Univ London, Sch Elect Engn & Comp Sci, London, England
Hao, Yang
[1
]
论文数: 引用数:
h-index:
机构:
Khan, Ahsan Noor
[1
]
论文数: 引用数:
h-index:
机构:
Giddens, Henry
[1
]
论文数: 引用数:
h-index:
机构:
Sukhorukov, Gleb
[2
]
机构:
[1] Queen Mary Univ London, Sch Elect Engn & Comp Sci, London, England
[2] Queen Mary Univ London, Sch Engn & Mat Sci, London, England
来源:
2019 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND USNC-URSI RADIO SCIENCE MEETING
|
2019年
关键词:
Targeted drug delivery;
healthcare;
complementary split ring resonator;
D O I:
10.1109/apusncursinrsm.2019.8888394
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
Drug delivery devices have been recently emerged as a significant facet of therapeutic treatment. Most of the devices comprises of tiny reservoir based structures for carrying and delivering drugs to a targeted location in human body. In this paper, the material characterization of microchamber arrays is presented. The microchamber arrays were prepared in the thin layer of Graphene Oxide deposited on a glass substrate. In the next step, the complementary split ring resonator (CSRR) sensor was used to characterize the tiny reservoirs of microchamber arrays. It was observed that the permittivity of microchamber arrays have an impact on the resonant frequency of CSRR.