A novel spectrophotometric method for determination of cyanide using cobalt (II) phthalocyanine tetracarboxylate as a chromogen

被引:4
作者
El-Nemma, Eman M. [2 ]
Abd-Rabboh, Hisham S. M. [1 ]
Hassan, Saad S. M. [1 ]
机构
[1] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
[2] Qatar Univ, Fac Arts & Sci, Dept Chem, Doha, Qatar
关键词
electroplating wastewater; cobalt (II) phthalocyanine tetracarboxylate chromogen; spectrophotometry; determination of cyanide; FLOW-INJECTION DETERMINATION; SELECTIVE DETERMINATION; WASTE-WATER; ACID; ELECTRODE; MATRICES; SYSTEM; IONS;
D O I
10.1080/03067310903276274
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cobalt (II) phthalocyanine tetracarboxylate [Co (II)Pc-COOH] has been prepared and used in aqueous solutions as a novel chromogenic reagent for the spectrophotometric determination of cyanide ion. The method is based on measuring the increase in the intensity of the monomer peak in the reagent absorbance at 682 nm due to the formation of a 1 : 2 [Co (II)Pc-COOH] : [CN] complex. The complex exhibits a molar absorptivity (epsilon) of 7.7 x 10(4) L mol(-1) cm(-1) and a formation constant (K-f) of 5.4 perpendicular to 0.01 x 10(6) at 25 perpendicular to 0.1 degrees C. Beer's law is obeyed over the concentration range 0.15-15 mu g mL(-1) (5.8 x 10 (6)-5.8 x 10 (4) M) of cyanide ion, the detection limit is 20 ng mL(-1) (7.7 x 10(-7) M) the relative standard deviation is +/-0.7% (n = 6) and the method accuracy is 98.6 +/- 0.9%. Interference by most common ions is negligible, except that by sulphite. The proposed method is used for determining cyanide concentration in gold, silver and chromium electroplating wastewater bath solutions after a prior distillation with 1 : 1 H2SO4 and collection of the volatile cyanide in 1 M NaOH solution containing lead carbonate as recommended by ASTM, USEPA, ISO and APAHE separation procedures. The results agree fairly well with potentiometric data obtained using the solid state cyanide ion selective electrode.
引用
收藏
页码:148 / 158
页数:11
相关论文
共 49 条
[1]  
[Anonymous], 1998, STAND METH EX WAT WA, V20th
[2]  
*ASTM INT, 2007, D203606 ASTM INT
[3]   Cyanide binding to phthalocyaninatoiron(II) in dimethyl sulfoxide in the presence of carbon monoxide: kinetic and equilibrium study [J].
Boffi, A ;
Ercolani, C ;
Monacelli, F ;
Ascenzi, P .
INORGANICA CHIMICA ACTA, 1998, 267 (01) :109-114
[4]  
CHIEN CC, 1980, MIKROCHIM ACTA, V2, P9
[5]   SYSTEMATIC VARIATION OF METAL-METAL BOND ORDER IN METALLOPORPHYRIN DIMERS [J].
COLLMAN, JP ;
BARNES, CE ;
WOO, LK .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-PHYSICAL SCIENCES, 1983, 80 (24) :7684-7688
[6]  
DOUDOROFF P, 1966, T AM FISH SOC, V95, P6, DOI 10.1577/1548-8659(1966)95[6:ATTFOS]2.0.CO
[7]  
2
[8]  
DOUDOROFF P, 1950, SEWAGE IND WASTES, V22, P1432
[9]  
DOUDOROFF P, 1976, 60037638 US EPA
[10]   Fast and highly selective determination of cyanide with 2,2-dihydroxy-1,3-indanedione [J].
Drochioiu, G .
TALANTA, 2002, 56 (06) :1163-1165