CIEF-CZE-MS applying a mechanical valve

被引:28
作者
Huehner, Jens [1 ,2 ]
Neusuess, Christian [1 ]
机构
[1] Aalen Univ, Fac Chem, Beethovenstr 1, D-73430 Aalen, Germany
[2] Univ Tubingen, Inst Pharmaceut Sci, Morgenstelle 8, D-72076 Tubingen, Germany
关键词
Capillary isoelectric focusing; Mass spectrometry; Online hyphenation; Protein; Two-dimensional separation; ELECTROSPRAY MASS-SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; PROTEIN-ANALYSIS; PLATFORM;
D O I
10.1007/s00216-016-9498-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Separation and determination of proteins by capillary isoelectric focusing (CIEF) and mass spectrometry (MS) are essential and complementary techniques in the field of bioanalysis. The hyphenation of these two techniques is challenging due to the nonvolatile substances required for the CIEF separation. An additional separation step prior to MS enables the removal of the nonvolatile substances. However, it is complicated due to the small transfer volume and the required high voltages in the CIEF process. In order to remove nonvolatile substances and transfer the analytes toward the mass spectrometer, we applied a four-port valve to couple CIEF online to capillary electrophoresis-mass spectrometry. To demonstrate the power of this concept, hemoglobin and glycated hemoglobin with an isoelectric point difference of 0.037 were separated via isoelectric focusing and characterized by MS. In general, this setup guaranties interference-free mass spectra and will provide an information-rich and sensitive top down protein characterization.
引用
收藏
页码:4055 / 4061
页数:7
相关论文
共 17 条
[1]   Capillary isoelectric focusing-based multidimensional concentration/separation platform for proteome analysis [J].
Chen, JZ ;
Balgley, BM ;
DeVoe, DL ;
Lee, CS .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3145-3152
[2]   ISOELECTRIC FOCUSING AND TWO-DIMENSIONAL GEL ELECTROPHORESIS [J].
Friedman, David B. ;
Hoving, Sjouke ;
Westermeier, Reiner .
GUIDE TO PROTEIN PURIFICATION, SECOND EDITION, 2009, 463 :515-540
[3]  
HEMPE JM, 1994, CLIN CHEM, V40, P2288
[4]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270
[5]   Capillary isoelectric focusing-mass spectrometry: Coupling strategies and applications [J].
Huehner, Jens ;
Laemmerhofer, Michael ;
Neusuess, Christian .
ELECTROPHORESIS, 2015, 36 (21) :2670-2686
[6]   OBSERVATION OF THE HEME GLOBIN COMPLEX IN NATIVE MYOGLOBIN BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY [J].
KATTA, V ;
CHAIT, BT .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (22) :8534-8535
[7]   Column-coupling strategies for multidimensional electrophoretic separation techniques [J].
Kler, Pablo A. ;
Sydes, Daniel ;
Huhn, Carolin .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (01) :119-138
[8]   On-line two-dimensional capillary electrophoresis with mass spectrometric detection using a fully electric isolated mechanical valve [J].
Kohl, Felix J. ;
Montealegre, Cristina ;
Neusuess, Christian .
ELECTROPHORESIS, 2016, 37 (7-8) :954-958
[9]   Capillary electrophoresis in two-dimensional separation systems: Techniques and applications [J].
Kohl, Felix J. ;
Sanchez-Hernandez, Laura ;
Neusuess, Christian .
ELECTROPHORESIS, 2015, 36 (01) :144-158
[10]   Use of microdialysis for the on-line coupling of capillary isoelectric focusing with electrospray mass spectrometry [J].
Lamoree, MH ;
Tjaden, UR ;
vanderGreef, J .
JOURNAL OF CHROMATOGRAPHY A, 1997, 777 (01) :31-39