Toric ICL Implantation After Sequential Intracorneal Ring Segments Implantation and Corneal Cross-linking in Keratoconus: 2-Year Follow-up

被引:22
作者
Abdelmassih, Youssef [1 ,2 ]
el-Khoury, Sylvain [1 ,2 ]
Chelala, Elias [2 ]
Slim, Elise [1 ,2 ]
Cherfan, Carole G. [1 ]
Jarade, Elias [1 ,3 ]
机构
[1] Beirut Eye Specialist Hosp, Al Mathaf Sq,POB 116-5311, Beirut, Lebanon
[2] St Joseph Univ, Fac Med, Beirut, Lebanon
[3] Mediclin Dubai Mall, Dubai, U Arab Emirates
关键词
PHAKIC INTRAOCULAR-LENS; MYOPIC ASTIGMATISM; COLLAMER LENS; INTACS; EYES;
D O I
10.3928/1081597X-20170621-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate 6-month and 2-year safety and clinical outcomes of Visian toric Implantable Collamer Lens (toric ICL) (STAAR Surgical, Monrovia, CA) implantation for the treatment of residual refractive errors after sequential intracorneal ring segments (ICRS) insertion and cross-linking (CXL) in keratoconus. METHODS: This consecutive case series included the results of a three-step ICRS-CXL-toric ICL procedure in 16 eyes of 13 patients with moderate to severe keratoconus (stages II and III of Amsler-Krumeich classification). The ICRS and CXL procedures were performed sequentially with an interval of 4 weeks and the toric ICL implantation was performed at least 6 months after CXL. Data were collected preoperatively, at 6 months after sequential ICRS-CXL, and at 6 and 24 months following toric ICL implantation. All 16 eyes were evaluated at the 2-year follow-up. RESULTS: There was a significant decrease in keratometry (steep, flat, and maximum) and refraction (sphere and spherical equivalence, but not cylinder) and a significant increase in both uncorrected (UDVA) (from 1.06 to 0.76 logMAR, P =.004) and corrected (CDVA) (from 0.42 to 0.26 logMAR; P =.002) distance visual acuity 6 months following sequential ICRS-CXL, whereas UDVA and refraction significantly improved 6 months after ICL insertion (UDVA reached 0.33 logMAR, P =.001). At the 24-month follow-up, UDVA and keratometric readings were stable, whereas CDVA, sphere, and cylinder showed a significant improvement. CONCLUSIONS: Implantation of Visian toric ICL following sequential ICRS insertion and CXL is an effective and safe option for correcting high residual refractive error and improving visual acuity in patients with moderate to severe keratoconus in the long term.
引用
收藏
页码:610 / +
页数:8
相关论文
共 24 条
[1]   Intrastromal corneal ring segments and posterior chamber phakic intraocular lens implantation for keratoconus correction [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Fernandez-Vega, Luis ;
Madrid-Costa, David ;
Poo-Lopez, Arancha ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (04) :706-713
[2]   Collagen copolymer toric posterior chamber phakic intraocular lens in eyes with keratoconus [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Lisa, Carlos ;
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06) :906-916
[3]   Safety and Visual Outcome of Visian Toric ICL Implantation after Corneal Collagen Cross-Linking in Keratoconus: Up to 2 Years of Follow-Up [J].
Antonios, Rafic ;
Dirani, Ali ;
Fadlallah, Ali ;
Chelala, Elias ;
Hamade, Adib ;
Cherfane, Carole ;
Jarade, Elias .
JOURNAL OF OPHTHALMOLOGY, 2015, 2015
[4]   Long-term Results of Riboflavin Ultraviolet A Corneal Collagen Cross-linking for Keratoconus in Italy: The Siena Eye Cross Study [J].
Caporossi, Aldo ;
Mazzotta, Cosimo ;
Baiocchi, Stefano ;
Caporossi, Tomaso .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 149 (04) :585-593
[5]   Effect of inferior-segment Intacs with and without C3-R on keratoconus [J].
Chan, Colin C. K. ;
Sharma, Munish ;
Wachler, Brian S. Boxer .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (01) :75-80
[6]   Combined intacs and posterior chamber toric Implantable collamer lens implantation for keratoconic patients with extreme myopia [J].
Coskunseven, Efekan ;
Onder, Methiye ;
Kymionis, George D. ;
Diakonis, Vasilios F. ;
Arslan, Ebru ;
Tsiklis, Nikolaos ;
Bouzoukis, Dimitrios I. ;
Pallikaris, Ioannis .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (03) :387-389
[7]   Collagen copolymer toric phakic intraocular lens for residual myopic astigmatism after intrastromal corneal ring segment implantation and corneal collagen crosslinking in a 3-stage procedure for keratoconus [J].
Coskunseven, Efekan ;
Sharma, Daya Papalkar ;
Jankov, Mirko R., II ;
Kymionis, George D. ;
Richoz, Olivier ;
Hafezi, Farhad .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (05) :722-729
[8]   Visian toric ICL implantation after intracorneal ring segments implantation and corneal collagen crosslinking in keratoconus [J].
Dirani, Ali ;
Fadlallah, Ali ;
Khoueir, Ziad ;
Antoun, Joelle ;
Cherfan, George ;
Jarade, Elias .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (03) :338-344
[9]   Sequential Intacs and Verisyse phakic intraocular lens for refractive improvement in keratoconic eyes [J].
El-Raggal, Tamer M. ;
Abdel Fattah, Adel A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (06) :966-970
[10]   Non-topography-guided PRK Combined With CXL for the Correction of Refractive Errors in Patients With Early Stage Keratoconus [J].
Fadlallah, Ali ;
Dirani, Ali ;
Chelala, Elias ;
Antonios, Rafic ;
Cherfan, George ;
Jarade, Elias .
JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (10) :688-693