An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles

被引:18
|
作者
Wang, Yazhen [1 ,2 ]
Song, Bin [2 ]
Xu, Junhui [2 ]
Hu, Shengshui [3 ]
机构
[1] Jianghan Univ, Minist Educ, Key Lab Optoelect Chem Mat & Devices, Wuhan 430056, Peoples R China
[2] Jianghan Univ, Sch Chem & Environm Engn, Wuhan 430056, Peoples R China
[3] Wuhan Univ, Dept Chem, Wuhan 430079, Peoples R China
基金
中国国家自然科学基金;
关键词
Nitric oxide; Graphene; Electrodeposited Au nanoparticles; Amperometry; Sensor; FILM; FIBER; ELECTROCHEMISTRY; VOLTAMMETRY; MICROSENSOR; HEMOGLOBIN; RELEASE; SIZE;
D O I
10.1007/s00604-014-1379-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article describes the fabrication of a glassy carbon electrode (GCE) modified with a film containing graphene and gold nanoparticles (AuNPs) that can be used for the determination of nitric oxide (NO) at pH 7.0. A layer of gold nanoparticles was first deposited on the GCE, this followed by coating it with a film of graphene and Nafion. The response of the electrode to NO was studied by cyclic voltammetry and amperometry. A sharp anodic peak was observed at 0.81 V, and the anodic peak current was largely increased compared to a bare GCE or a mono-film modified GCE. A negative shift of the anodic peak potential (by 220 mV) indicates that the composite film has a beneficial effect on ease of the electrochemical oxidation of NO. The electron transfer number was calculated from chronocoulometric data. The amperometric response to NO is linear in the 36 nM to 20 mu M concentration range (with a correlation coefficient of 0.9981), and the detection limit is 18 nM (at a S/N of 3). The release of NO from the fish liver homogenate stimulated by L-arginine was studied with this electrode.
引用
收藏
页码:711 / 718
页数:8
相关论文
共 50 条
  • [41] A novel electrochemical sensor of bisphenol A based on stacked graphene nanofibers/gold nanoparticles composite modified glassy carbon electrode
    Niu, Xiuli
    Yang, Wu
    Wang, Guoying
    Ren, Jie
    Guo, Hao
    Gao, Jinzhang
    ELECTROCHIMICA ACTA, 2013, 98 : 167 - 175
  • [42] Determination of morphine at gold nanoparticles/Nafion® carbon paste modified sensor electrode
    Atta, Nada F.
    Galal, Ahmed
    Azab, Shereen M.
    ANALYST, 2011, 136 (22) : 4682 - 4691
  • [43] Amperometric Determination of Acetaminophen (paracetamol) Using Graphene Oxide Modified Glassy Carbon Electrode
    Alagarsamy, Periyalagan
    Settu, Ramki
    Chen, Shen-Ming
    Chen, Tse-Wei
    Hong, In-Seok
    Rao, Mettu Mallikarjuna
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (08): : 7930 - 7938
  • [44] Simple non-enzymatic electrochemical sensor for hydrogen peroxide based on nafion/platinum nanoparticles/reduced graphene oxide nanocomposite modified glassy carbon electrode
    Cong Zhang
    Haohai Jiang
    Rui Ma
    Yanyan Zhang
    Qiang Chen
    Ionics, 2017, 23 : 1309 - 1317
  • [45] Simple non-enzymatic electrochemical sensor for hydrogen peroxide based on nafion/platinum nanoparticles/reduced graphene oxide nanocomposite modified glassy carbon electrode
    Zhang, Cong
    Jiang, Haohai
    Ma, Rui
    Zhang, Yanyan
    Chen, Qiang
    IONICS, 2017, 23 (05) : 1309 - 1317
  • [46] Amperometric ascorbic acid sensor based on doped ferrites nanoparticles modified glassy carbon paste electrode
    Dimitrijevic, Teodora
    Vulic, Predrag
    Manojlovic, Dragan
    Nikolic, Aleksandar S.
    Stankovic, Dalibor M.
    ANALYTICAL BIOCHEMISTRY, 2016, 504 : 20 - 26
  • [47] Enhancing Dopamine Detection Using Glassy Carbon Electrode Modified with Graphene Oxide, Nickel and Gold Nanoparticles
    Hassine, Chedia Ben Ali
    Kahri, Hamza
    Barhoumi, Houcine
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (02)
  • [48] Electrochemical determination of glutathione based on an electrodeposited nickel oxide nanoparticles-modified glassy carbon electrode
    Yuan, Baiqing
    Zeng, Xiaoying
    Deng, Dehua
    Xu, Chunying
    Liu, Lin
    Zhang, Jiayu
    Gao, Yan
    Pang, Huan
    ANALYTICAL METHODS, 2013, 5 (07) : 1779 - 1783
  • [49] Electrochemical oxidation of sulfamethazine on a glassy carbon electrode modified with graphene and gold nanoparticles
    Cesarino, Ivana
    Simoes, Rafael Plana
    Lavarda, Francisco Carlos
    Batagin-Neto, Augusto
    ELECTROCHIMICA ACTA, 2016, 192 : 8 - 14
  • [50] Non-enzymatic amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with gold nanoparticles deposited on CVD-grown graphene
    Yawen Yuan
    Yiqun Zheng
    Jinglei Liu
    Hua Wang
    Shifeng Hou
    Microchimica Acta, 2017, 184 : 4723 - 4729