Performance of two new automated assays for measuring von Willebrand activity: HemosIL Acu Star and Innovance

被引:32
作者
de Maistre, Emmanuel [1 ]
Volot, Fabienne [2 ]
Mourey, Guillaume [3 ]
Aho, Ludwig S. [4 ]
Ternisien, Catherine [5 ]
Briquel, Marie-Elisabeth [6 ]
Bertrand, Marie-Anne [7 ]
Tardy, Brigitte [8 ]
Frotscher, Birgit [6 ]
Nguyen, Philippe [9 ]
Dumont, Laure [10 ]
Vandroux, David
Hezard, Nathalie [9 ]
Trossaert, Marc [5 ]
机构
[1] Univ Hosp, Haematol Lab, Dijon, France
[2] Univ Hosp, Haemophilia Ctr, Dijon, France
[3] Etab Francais Sang, Besancon, France
[4] Univ Hosp, Dept Epidemiol, Dijon, France
[5] Univ Hosp, Haematol Lab, Nantes, France
[6] Univ Hosp, Haemophilia Ctr, Nancy, France
[7] Univ Hosp, Haemophilia Ctr, Besancon, France
[8] Univ Hosp, Haematol Lab, St Etienne, France
[9] Univ Hosp, Haematol Lab, Reims, France
[10] NVH Med, Dijon, France
关键词
Willebrand activity assay; ristocetin cofactor activity; aggregometry; von Willebrand disease; FACTOR RISTOCETIN COFACTOR; DISEASE; DIAGNOSIS; VALIDATION; ANTIGEN;
D O I
10.1160/TH14-02-0108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The ristocetin cofactor activity assay (VWF:RCo) is the reference method for assessing von Willebrand factor (VWF) activity but remains difficult to perform, and the coefficient of variation of the method is high (about 20-30%). This study evaluated and compared the performance for measuring the VWF activity of two newly commercialised assays [VWF:Ac Innovance (VWF:Ac) and VWF:RCo Acustar (VWF:RCo Acu)] with the reference VWF:RCo aggregation in 123 pathological plasma samples. The correlation and concordance between both new tests (VWF:RCo-Acu and VWF:Ac) and the reference VWF:RCo were good. The results of the VWF activity to VWF antigen ratio were also comparable whatever the method for the classification of VWF deficiency in all patients. Our results showed that both new tests could replace the "gold standard" VWF:RCo in aggregometry with several benefits: they are fully automated, easier and faster to perform, better adapted to emergency situations if necessary.
引用
收藏
页码:825 / 830
页数:6
相关论文
共 17 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Comparison of a new chemiluminescent immunoassay for von Willebrand factor activity with the ristocetin cofactor-induced platelet agglutination method [J].
Cabrera, N. ;
Moret, A. ;
Caunedo, P. ;
Cid, A. R. ;
Vila, V. ;
Espana, F. ;
Aznar, J. A. .
HAEMOPHILIA, 2013, 19 (06) :920-925
[3]  
Castaman G, 2003, HAEMATOLOGICA, V88, P94
[4]   Validation of improved performance characteristics for the automated von Willebrand factor ristocetin cofactor activity assay [J].
Favaloro, E. J. ;
Mohammed, S. ;
McDonald, J. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2010, 8 (12) :2842-2844
[5]   von Willebrand disease: laboratory aspects of diagnosis and treatment [J].
Favaloro, EJ ;
Lillicrap, D ;
Lazzari, MA ;
Cattaneo, M ;
Mazurier, C ;
Woods, A ;
Meschengieser, S ;
Blanco, A ;
Kempfer, AC ;
Hubbard, A ;
Chang, A .
HAEMOPHILIA, 2004, 10 :164-168
[6]  
Favaloro Emmanuel J, 2008, Clin Lab Sci, V21, P178
[8]   Screening for von Willebrand disease: contribution of an automated assay for von Willebrand factor activity [J].
Lasne, D. ;
Dey, C. ;
Dautzenberg, M. -D. ;
Cherqaoui, Z. ;
Monge, F. ;
Aouba, A. ;
Torchet, M. -F. ;
Geloen, D. ;
Landais, P. ;
Rothschild, C. .
HAEMOPHILIA, 2012, 18 (03) :e158-e163
[9]   A comparative evaluation of a new automated assay for von Willebrand factor activity [J].
Lawrie, A. S. ;
Stufano, F. ;
Canciani, M. T. ;
Mackie, I. J. ;
Machin, S. J. ;
Peyvandi, F. .
HAEMOPHILIA, 2013, 19 (02) :338-342
[10]   A CONCORDANCE CORRELATION-COEFFICIENT TO EVALUATE REPRODUCIBILITY [J].
LIN, LI .
BIOMETRICS, 1989, 45 (01) :255-268