Energy and exergy analysis of a novel solar-air composite source multi-functional heat pump

被引:17
作者
Cai, Jingyong [1 ]
Zhou, Haihua [1 ]
Xu, Lijie [3 ]
Shi, Zhengrong [1 ]
Zhang, Tao [1 ]
Ji, Jie [2 ]
机构
[1] Shanghai Univ Elect Power, Coll Energy & Mech Engn, Shanghai, Peoples R China
[2] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei, Anhui, Peoples R China
[3] Jimei Univ, Sch Marine Engn, Xiamen 361021, Peoples R China
关键词
Multi-functional; Heat pump; Composite source; Solar-assisted; Air source; RANKINE-CYCLE; THERMOECONOMIC OPTIMIZATION; PERFORMANCE; REFRIGERATION; SYSTEMS; POWER; SIMULATION; OPERATION;
D O I
10.1016/j.renene.2021.12.033
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
As multi-functional heat pump with higher equipment utilization rate will face more complicated operation condition, the integration with composite heat source will be good solution to improve the operational stability and output performance. In this paper, a novel solar-air composite source multifunctional heat pump (SA-CMHP) has been proposed. Different from conventional single-source heat pump, the proposed system has two evaporators operating in parallel in space heating mode. As the distribution of refrigerant at evaporation side is associated with the output performance of SA-CMHP, the space heating performance under different refrigerant distribution ratio (g) has been studied based on energy and exergy methods. Besides, economic performance of SA-CMHP for space heating has been analyzed and compared with single-source heat pump. The results indicate that with the increase of g, the variation of evaporation capacity, power consumption, heating capacity, COP and exergy efficiency tends to increase at first and then decrease. When solar irradiation is 200W/m(2), 300W/m(2) and 400W/m(2), COP and exergy efficiency reach the highest value at g of 0.6, 0.7 and 0.8. When ambient temperature is 4 degrees C, 7 degrees C and 10 degrees C, COP and exergy efficiency reach the peak values at g of 0.6. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:32 / 46
页数:15
相关论文
共 39 条
[1]   A review on exergy analysis of vapor compression refrigeration system [J].
Ahamed, J. U. ;
Saidur, R. ;
Masjuki, H. H. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (03) :1593-1600
[2]   Multi-functional heat pumps integration in power plants for CO2 capture and sequestration [J].
Alabdulkarem, Abdullah ;
Hwang, Yunho ;
Radermacher, Reinhard .
APPLIED ENERGY, 2015, 147 :258-268
[3]   A chronological review of advances in solar assisted heat pump technology in 21st century [J].
Badiei, A. ;
Akhlaghi, Y. Golizadeh ;
Zhao, X. ;
Shittu, S. ;
Xiao, X. ;
Li, J. ;
Fan, Y. ;
Li, G. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 132
[4]  
Bai C., 2020, ENERGY BUILT ENV, V1, P1, DOI [10.1016/j.enbenv.2019.08.004, DOI 10.1016/J.ENBENV.2019.08.004]
[5]   Energy and exergy analysis of a novel solar-air composite source multi-functional heat pump [J].
Cai, Jingyong ;
Zhou, Haihua ;
Xu, Lijie ;
Shi, Zhengrong ;
Zhang, Tao ;
Ji, Jie .
RENEWABLE ENERGY, 2022, 185 (32-46) :32-46
[6]   Numerical simulation and experimental validation of indirect expansion solar-assisted multi-functional heat pump [J].
Cai, Jingyong ;
Ji, Jie ;
Wang, Yunyun ;
Huang, Wenzhu .
RENEWABLE ENERGY, 2016, 93 :280-290
[7]   Air Source Heat Pumps field studies: A systematic literature review [J].
Carroll, P. ;
Chesser, M. ;
Lyons, P. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 134
[8]   Determining of the optimal design of a closed loop solar dual source heat pump system coupled with a residential building application [J].
Chargui, Ridha ;
Awani, Sami .
ENERGY CONVERSION AND MANAGEMENT, 2017, 147 :40-54
[10]   Simulation analysis on dynamic performance of a combined solar/air dual source heat pump water heater [J].
Deng, Weishi ;