HEPA/vaccine plan for indoor anthrax remediation

被引:16
作者
Wein, LM
Liu, YF
Leighton, TJ
机构
[1] Stanford Univ, Grad Sch Business, Stanford, CA 94305 USA
[2] Childrens Hosp, Oakland Res Inst, Oakland, CA 94609 USA
关键词
D O I
10.3201/eid1101.040635
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
We developed a mathematical model to compare 2 indoor remediation strategies in the aftermath of an outdoor release of 1.5 kg of anthrax spores in lower Manhattan. The 2 strategies are the fumigation approach used after the 2001 postal anthrax attack and a HEPA/vaccine plan, which relies on HEPA vacuuming, HEPA air cleaners, and vaccination of reoccupants. The HEPA/vaccine approach leads to few anthrax cases among reoccupants if applied to all but the most heavily contaminated buildings, and recovery is much faster than under the decades-long fumigation plan. Only modest environmental sampling is needed. A surge capacity of 10,000 to 20,000 Hazmat workers is required to perform remediation within 6 to 12 months and to avoid permanent mass relocation. Because of the possibility of a campaign of terrorist attacks, serious consideration should be given to allowing or encouraging voluntary self-service cleaning of lightly contaminated rooms by age-appropriate, vaccinated, partially protected (through masks or hoods) reoccupants or owners.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 21 条
[11]  
*EPA, 2003, INT FIN WTC RES CONF, V1
[12]   DISCUSSION OF BRACHMAN PS [J].
GLASSMAN, HN .
BACTERIOLOGICAL REVIEWS, 1966, 30 (03) :657-&
[13]   On the risk of mortality to primates exposed to anthrax spores [J].
Haas, CN .
RISK ANALYSIS, 2002, 22 (02) :189-193
[14]  
KOMINSKY JR, 1990, AM IND HYG ASSOC J, V51, P500, DOI 10.1080/15298669091369998
[15]  
Kowalski W., 2003, J ARCHIT ENG, V9, P86, DOI [10.1061/(ASCE)1076-0431(2003)9:2(86), DOI 10.1061/(ASCE)1076-0431(2003)9:2(86)]
[16]   THE SVERDLOVSK ANTHRAX OUTBREAK OF 1979 [J].
MESELSON, M ;
GUILLEMIN, J ;
HUGHJONES, M ;
LANGMUIR, A ;
POPOVA, I ;
SHELOKOV, A ;
YAMPOLSKAYA, O .
SCIENCE, 1994, 266 (5188) :1202-1208
[17]  
*NAT I OCC SAF HLT, 2003, DHHS NIOSH PUB
[18]  
Rickmeier GL., 2001, MIL OPER RES, V6, P35, DOI DOI 10.5711/MORJ.6.3.35
[19]  
STROHM C, 2004, WASHINGTON POSTAL FA
[20]  
U. S. Department of Energy, 1997, DOESTD302097