REAL-TIME CONTRAST-ENHANCED ULTRASOUND FOR THE ASSESSMENT OF PERFUSION DYNAMICS IN SKELETAL MUSCLE

被引:31
作者
Krix, Martin [1 ,2 ]
Krakowski-Roosen, Holger [3 ]
Kauczor, Hans-Ulrich [4 ]
Delorme, Stefan [1 ]
Weber, Marc-Andre [1 ,4 ]
机构
[1] German Canc Res Ctr Heidelberg, Res Program Imaging & Radiooncol, Dept Radiol, D-69120 Heidelberg, Germany
[2] Bracco Imaging Germany, Constance, Germany
[3] German Canc Res Ctr Heidelberg, Dept Immunochem, D-69120 Heidelberg, Germany
[4] Univ Heidelberg Hosp, Dept Diagnost & Intervent Radiol, Heidelberg, Germany
关键词
Skeletal muscle perfusion; Real-time contrast-enhanced ultrasound; Venous occlusion plethysmography; BLOOD-FLOW; CAPILLARY RECRUITMENT; ULTRASONOGRAPHY;
D O I
10.1016/j.ultrasmedbio.2009.05.006
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We developed a real-time low-MI contrast-enhanced ultrasound method (CEUS), compared it with venous occlusion plethysmography (VOP) and evaluated its robustness in the quantification of skeletal muscle perfusion during exercise. Contrast pulse sequencing (7 MHz) during continuous intravenous infusion of SonoVue (4.8 mL/300s) was used repeatedly in eight healthy volunteers to monitor changes of the muscle perfusion before, during and after isometric exercises (10 to 50% of individual maximum strength for 20 to 30 s) of the gastrocnemius muscle in real time. CEUS was correlated with VOP at different time points, and the exactness of several CEUS parameters obtained from ultrasound-signal-intensity-time curves was evaluated. Real-time CEUS depicted a large variability of the skeletal muscle blood volume at rest (mean, 3.48; range, 0.60 to 9.92 [similar to mL]), with a significant reproducibility (r = 0.72, p <0.05) and correlation with VOP (r = 0.59, p <0.001). Mean blood volume during exercise was 1.58(similar to mL), increased to a mean maximum after exercise of 8.88(similar to mL), the mean change of the local blood volume during and directly after the exercise was -0.10 and +1.57(similar to mL/s). The average CEUS signal during exercise decreased (mean area under the curve, -50.4[similar to mL.s]) and subsequently increased post exercise (mean 118.6[similar to mL.s]). CEUS parameters could be calculated with mean relative errors between 6 and 36%. Continuous assessment of local muscle microcirculation during exercise is possible with real-time CEUS with an acceptable robustness. Its application may be of particular interest in a better understanding of the role of perfusion during muscle training, and the monitoring of pathological vascular response, such as in diabetic microvessel diseases. (E-mail: martin.krix@kabelbw.de) (C) 2009 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1587 / 1595
页数:9
相关论文
共 16 条
[1]  
[Anonymous], ACTA ONCOL
[2]   A new formalism for the quantification of tissue perfusion by the destruct ion-replenishment method in contrast ultrasound Imaging [J].
Arditi, Marcel ;
Frinking, Peter J. A. ;
Zhou, Xiang ;
Rognin, Nicolas G. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (06) :1118-1129
[3]   Skeletal muscle vasodilatation at the onset of exercise [J].
Clifford, Philip S. .
JOURNAL OF PHYSIOLOGY-LONDON, 2007, 583 (03) :825-833
[4]   Vasodilatory mechanisms in contracting skeletal muscle [J].
Clifford, PS ;
Hellsten, Y .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 97 (01) :393-403
[5]   Physiologic hyperinsulinemia enhances human skeletal muscle perfusion by capillary recruitment [J].
Coggins, M ;
Lindner, J ;
Rattigan, S ;
Jahn, L ;
Fasy, E ;
Kaul, S ;
Barrett, E .
DIABETES, 2001, 50 (12) :2682-2690
[6]   Analysis of muscle microcirculation in advanced diabetes mellitus by contrast enhanced ultrasound [J].
Duerschmied, D. ;
Maletzki, P. ;
Freund, G. ;
Olschewski, M. ;
Seufert, J. ;
Bode, C. ;
Hehrlein, C. .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2008, 81 (01) :88-92
[7]   Contrast ultrasound perfusion imaging of lower extremities in peripheral arterial disease: a novel diagnostic method [J].
Duerschmied, D ;
Olson, L ;
Olschewski, M ;
Rossknecht, A ;
Freund, G ;
Bode, C ;
Hehrlein, C .
EUROPEAN HEART JOURNAL, 2006, 27 (03) :310-315
[8]   Influence of bubble size distribution on the echogenicity of ultrasound contrast agents -: A study of SonoVue™ [J].
Gorce, JM ;
Arditi, M ;
Schneider, M .
INVESTIGATIVE RADIOLOGY, 2000, 35 (11) :661-671
[9]   From Belfast to Mayo and beyond: the use and future of plethysmography to study blood flow in human limbs [J].
Joyner, MJ ;
Dietz, NM ;
Shepherd, JT .
JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (06) :2431-2441
[10]   Assessment of skeletal muscle perfusion using contrast-enhanced ultrasonography [J].
Krix, M ;
Weber, MA ;
Krakowski-Roosen, H ;
Huttner, HB ;
Delorme, S ;
Kauczor, HU ;
Hildebrandt, W .
JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (04) :431-441