摘要
Hybrid MR-linac systems can use fast dynamic MR sequences for tumor tracking and adapt the radiation treatment in real-time. For this the imaging latency must be as short as possible. This work describes how different acquisition parameters influence this latency. First, the latency was measured for Cartesian readouts with phase encode orderings linear, reverse-linear, and high-low. Second, the latency was measured for radial readouts with linear and golden angle profile orderings. To reduce the latency, a spatio-temporal (k-t) filter that suppresses the k-space center of earlier acquired spokes was implemented for the golden angle sequence. For Cartesian readouts a high-low ordering achieved a three times lower latency compared to a linear ordering with our sampling parameters. For radial readouts the filter was able to reduce the acquisition latency from half the acquisition time to a quarter of the acquisition time. The filter did not compromise the signal-to-noise ratio and the artifact power.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Dosimetric feasibility of MRI-guided external beam radiotherapy of the kidney
    Stam, Mette K.
    van Vulpen, Marco
    Barendrecht, Maurits M.
    Zonnenberg, Bernard A.
    Crijns, Sjoerd P. M.
    Lagendijk, Jan Jw
    Raaymakers, Bas W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (14) : 4933 - 4941
  • [22] The impact of 2D cine MR imaging parameters on automated tumor and organ localization for MR-guided real-time adaptive radiotherapy
    Menten, Martin J.
    Fast, Martin F.
    Wetscherek, Andreas
    Rank, Christopher M.
    Kachelriess, Marc
    Collins, David J.
    Nill, Simeon
    Oelfke, Uwe
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (23)
  • [23] Improved real-time tagged MRI using REALTAG
    Chen, Weiyi
    Lee, Nam Gyun
    Byrd, Dani
    Narayanan, Shrikanth
    Nayak, Krishna S.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 838 - 846
  • [24] Dynamic recurrent inference machines for accelerated MRI-guided radiotherapy of the liver
    Lonning, Kai
    Caan, Matthan W. A.
    Nowee, Marlies E.
    Sonke, Jan-Jakob
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2024, 113
  • [25] Technical Challenges of Real-Time Adaptive MR-Guided Radiotherapy
    Thorwarth, Daniela
    Low, Daniel A.
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [26] Recommendations for real-time speech MRI
    Lingala, Sajan Goud
    Sutton, Brad P.
    Miquel, Marc E.
    Nayak, Krishna S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) : 28 - 44
  • [27] Image Denoising for Real-Time MRI
    Klosowski, Jakob
    Frahm, Jens
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1340 - 1352
  • [28] An image regression motion prediction technique for MRI-guided radiotherapy evaluated in single-plane cine imaging
    Ginn, John S.
    Ruan, Dan
    Low, Daniel A.
    Lamb, James M.
    MEDICAL PHYSICS, 2020, 47 (02) : 404 - 413
  • [29] Dynamic coil selection for real-time imaging in interventional MRI
    Mueller, Sven
    Umathum, Reiner
    Speier, Peter
    Zuehlsdorff, Sven
    Ley, Sebastian
    Semmler, Wolfhard
    Bock, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (05) : 1156 - 1162
  • [30] Determination of internal target volume with Cine-MRI sequence for prostate MRI-Guided radiotherapy
    Wei, Ran
    Liang, Bin
    Men, Kuo
    Qin, Shirui
    Gao, Linrui
    Lu, Ningning
    Dai, Jianrong
    MEDICAL PHYSICS, 2024, 51 (05) : 3566 - 3577