Characterization of imaging latency for real-time MRI-guided radiotherapy

被引:41
作者
Borman, P. T. S. [1 ,2 ]
Tijssen, R. H. N. [1 ]
Bos, C. [2 ]
Moonen, C. T. W. [2 ]
Raaymakers, B. W. [1 ]
Glitzner, M. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Imaging Div, Heidelberglaan 100, Utrecht, Netherlands
关键词
MR-linac; real-time MRI; imaging latency; radial MRI; MR-guided tracking; readout ordering; TARGET TRACKING; DYNAMIC MRI; COMPENSATION; MOTION; RECONSTRUCTION; MLC; PERFORMANCE; PREDICTION; ORGANS;
D O I
10.1088/1361-6560/aad2b7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hybrid MR-linac systems can use fast dynamic MR sequences for tumor tracking and adapt the radiation treatment in real-time. For this the imaging latency must be as short as possible. This work describes how different acquisition parameters influence this latency. First, the latency was measured for Cartesian readouts with phase encode orderings linear, reverse-linear, and high-low. Second, the latency was measured for radial readouts with linear and golden angle profile orderings. To reduce the latency, a spatio-temporal (k-t) filter that suppresses the k-space center of earlier acquired spokes was implemented for the golden angle sequence. For Cartesian readouts a high-low ordering achieved a three times lower latency compared to a linear ordering with our sampling parameters. For radial readouts the filter was able to reduce the acquisition latency from half the acquisition time to a quarter of the acquisition time. The filter did not compromise the signal-to-noise ratio and the artifact power.
引用
收藏
页数:9
相关论文
共 31 条
[1]  
[Anonymous], 2018, PHILIPS MANUAL INGEN
[2]   Effect of MLC tracking latency on conformal volumetric modulated arc therapy (VMAT) plans in 4D stereotactic lung treatment [J].
Bedford, James L. ;
Fast, Martin F. ;
Nil, Simeon ;
McDonald, Fiona M. A. ;
Ahmed, Merina ;
Hansen, Vibeke N. ;
Oelfke, Uwe .
RADIOTHERAPY AND ONCOLOGY, 2015, 117 (03) :491-495
[3]   Analysis and compensation of eddy currents in balanced SSFP [J].
Bieri, O ;
Markl, M ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) :129-137
[4]   Particle Filter-Based Target Tracking Algorithm for Magnetic Resonance-Guided Respiratory Compensation: Robustness and Accuracy Assessment [J].
Bourque, Alexandra E. ;
Bedwani, Phane ;
Carrier, Jean-Francois ;
Menard, Cynthia ;
Borman, Pim ;
Bos, Clemens ;
Raaymakers, Bas W. ;
Mickevicius, Nikolai ;
Paulson, Eric ;
Tijssen, Rob H. N. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (02) :325-334
[5]   Free-breathing pediatric MRI with nonrigid motion correction and acceleration [J].
Cheng, Joseph Y. ;
Zhang, Tao ;
Ruangwattanapaisarn, Nichanan ;
Alley, Marcus T. ;
Uecker, Martin ;
Pauly, John M. ;
Lustig, Michael ;
Vasanawala, Shreyas S. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) :407-420
[6]   Tumour auto-contouring on 2d cine MRI for locally advanced lung cancer: A comparative study [J].
Fast, Martin F. ;
Eiben, Bjorn ;
Menten, Martin J. ;
Wetscherek, Andreas ;
Hawkes, David J. ;
McClelland, Jamie R. ;
Oelflce, Uwe .
RADIOTHERAPY AND ONCOLOGY, 2017, 125 (03) :485-491
[7]   Nonuniform fast Fourier transforms using min-max interpolation [J].
Fessler, JA ;
Sutton, BP .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2003, 51 (02) :560-574
[8]   Real-time auto-adaptive margin generation for MLC-tracked radiotherapy [J].
Glitzner, M. ;
Fast, M. F. ;
de Senneville, B. Denis ;
Nill, S. ;
Oelfke, U. ;
Lagendijk, J. J. W. ;
Raaymakers, B. W. ;
Crijns, S. P. M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (01) :186-201
[9]   On the suitability of Elekta's Agility 160 MLC for tracked radiation delivery: closed-loop machine performance [J].
Glitzner, M. ;
Crijns, S. P. M. ;
de Senneville, B. Denis ;
Lagendijk, J. J. W. ;
Raaymakers, B. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (05) :2005-2017
[10]   Realistic Analytical Phantoms for Parallel Magnetic Resonance Imaging [J].
Guerquin-Kern, M. ;
Lejeune, L. ;
Pruessmann, K. P. ;
Unser, M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (03) :626-636