High Accuracy Measurement of Absorbed Dose to Water Using Optically Stimulated Luminescence Dosimeter in High-Energy Photon Beam Field

被引:0
|
作者
Goto, S. [1 ,2 ]
Hayashi, H. [1 ]
Yamaguchi, H. [2 ]
Shimizu, M. [2 ]
Akino, R. [3 ]
Sekiguchi, H. [3 ]
机构
[1] Kanazawa Univ, Coll Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, Japan
[2] Natl Inst Adv Ind Sci & Technol, Tokyo, Japan
[3] Nagase Landauer Ltd, Tsukuba, Ibaraki, Japan
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PO-GeP-T-4
引用
收藏
页码:E789 / E789
页数:1
相关论文
共 50 条
  • [31] Evaluation of the scatter field for high-energy photon beam attenuators
    Castellanos, ME
    Rosenwald, JC
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (02): : 277 - 290
  • [32] ASSESSMENT OF ABSORBED DOSE TO WATER IN HIGH ENERGY PHOTON BEAMS USING DIFFERENT CYLINDRICAL CHAMBERS
    Stancu, Elena
    Vancea, Catalin
    Valenta, Jiri
    Zeman, Josef
    Badita, Eugenia
    Scarisoreanu, Anca
    ROMANIAN REPORTS IN PHYSICS, 2015, 67 (02) : 693 - 699
  • [33] Absorbed Dose Measurement Using Radiophotoluminescent Glass Dosimeter in Therapeutic Proton Beam
    Chang, W.
    Koba, Y.
    Katayose, T.
    Hariu, M.
    Yasui, K.
    Saitoh, H.
    MEDICAL PHYSICS, 2016, 43 (06) : 3502 - 3502
  • [34] CALORIMETRIC STANDARD DEVICE FOR MEASUREMENT OF ABSORBED DOSE FOR HIGH-ENERGY PHOTONS AND ELECTRONS
    HOHLFELD, K
    JOURNAL BELGE DE RADIOLOGIE, 1975, 58 (06): : 475 - 479
  • [35] Cema-based formalism for the determination of absorbed dose for high-energy photon beams
    Hartmann, Gunther H.
    Andreo, Pedro
    Kapsch, Ralf-Peter
    Zink, Klemens
    MEDICAL PHYSICS, 2021, 48 (11) : 7461 - 7475
  • [37] The contribution of secondary heavy particles to the absorbed dose from high-energy photon beams
    Spurny, F
    Johansson, L
    Satherberg, A
    Bednar, J
    Turek, K
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12): : 2643 - 2656
  • [38] Measurement of gamma knife collimator factors using optically stimulated luminescence (OSL) dosimeter
    Tong, S.
    Yang, J.
    Yahnke, C.
    Beatty, R.
    King, S.
    Erdman, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2467 - 2468
  • [39] Absorbed dose to water standard of high-energy x-rays at the KRISS
    Kim, In Jung
    Kim, Yun Ho
    Yi, Chul-Young
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 81 (10) : 1004 - 1012
  • [40] Absorbed dose to water standard of high-energy x-rays at the KRISS
    In Jung Kim
    Yun Ho Kim
    Chul-Young Yi
    Journal of the Korean Physical Society, 2022, 81 : 1004 - 1012