The effect of hydrogen on fluorine detection in solid sampling electrothermal vaporization-inductively coupled plasma optical emission spectrometry

被引:7
作者
Maung, Patricia [1 ]
Beauchemin, Diane [1 ]
机构
[1] Queens Univ, Dept Chem, Kingston, ON K7L 3N6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
ETV-ICP-OES; HIGH-PURITY COPPER; MASS-SPECTROMETRY; TRACE-ELEMENTS; TUNGSTEN FURNACE; AQUEOUS SAMPLES; MODIFIERS; NITROGEN; GAS;
D O I
10.1039/d1ja00090j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effect on the detection of fluorine (F) in solid samples of adding H-2 to the carrier gas in electrothermal vaporization (ETV) coupled to inductively coupled plasma optical emission spectrometry (ICPOES) is studied for the first time. By incorporating H-2 as the reaction gas through the ETV graphite furnace, H-2 is introduced into the Ar plasma through the central channel of the ICP. An optimal flow rate for H-2 was determined to be 3 mL min(-1), with a pyrolysis temperature of 200 degrees C and a vaporization temperature of 2200 degrees C for the ETV program. Two reference materials, NIST 8432 Corn Starch and 8437 Hard Spring Wheat, were used to observe the changes in sensitivity and limit of detection (LOD) for F, following the addition of H-2. These materials were also used to verify the accuracy of the method through external calibration of both following internal standardization with an Ar 404.442 nm emission line to compensate for sample loading effects on the plasma. Compared to a previous ETV-ICPOES method that was optimized without H-2, LODs were improved 17-140 fold, depending on the F emission line, in plant-based materials. Additionally, similar or improved LODs resulted for Cd and Hg in NIST 8437 under the conditions optimized for the determination of F compared to those previously obtained with methods optimized for multi-elemental detection (excluding F).
引用
收藏
页码:1104 / 1111
页数:8
相关论文
共 40 条
[1]   Effect of sheathing the sample aerosol with hydrogen, nitrogen or water vapour on the analytical performance of solid sampling electrothermal vaporisation coupled to inductively coupled plasma optical emission spectrometry [J].
Al Hejami, Ahmed ;
Beauchemin, Diane .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (07) :1426-1432
[2]  
Beauchemin D., 2000, Discrete Sample Introduction Techniques for Inductively Coupled Plasma Mass Spectrometry
[3]  
Beauchemin D., 2020, Sample Introduction Systems in ICPMS and ICPOES, V1A
[4]   ELECTROTHERMAL VAPORIZATION FOR SAMPLE INTRODUCTION IN PLASMA SOURCE SPECTROMETRY [J].
CAREY, JM ;
CARUSO, JA .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1992, 23 (05) :397-439
[5]   ALTERNATIVES TO ALL-ARGON PLASMAS IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) - AN OVERVIEW [J].
DURRANT, SF .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (10-11) :389-392
[6]   THE ROLE OF CHEMICAL MODIFIERS IN ANALYTE TRANSPORT LOSS INTERFERENCES WITH ELECTROTHERMAL VAPORIZATION ICP-MASS SPECTROMETRY [J].
EDIGER, RD ;
BERES, SA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (07) :907-922
[7]   ATOMIC FLUORINE SPECTRA IN THE ARGON INDUCTIVELY COUPLED PLASMA [J].
FRY, RC ;
NORTHWAY, SJ ;
BROWN, RM ;
HUGHES, SK .
ANALYTICAL CHEMISTRY, 1980, 52 (11) :1716-1722
[8]   Optimization of fluorine determination via the molecular absorption of gallium mono-fluoride in a graphite furnace using a high-resolution continuum source spectrometer [J].
Gleisner, Heike ;
Welz, Bernhard ;
Einax, Juergen W. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (9-10) :864-869
[9]   ICP-AES ANALYSIS OF GASES IN ENERGY TECHNOLOGY AND INFLUENCE OF MOLECULAR ADDITIVES ON ARGON ICP [J].
GOLDFARB, VM ;
GOLDFARB, HV .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1985, 40 :177-194
[10]  
Government of Canada, DRINKING WATER QUALI