Single-Shot T1 Mapping Using Simultaneous Acquisitions of Spin- and Stimulated-Echo-Planar Imaging (2D ss-SESTEPI)

被引:7
|
作者
Shi, Xianfeng [2 ]
Kim, Seong-Eun [1 ]
Jeong, Eun-Kee [1 ]
机构
[1] Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Phys, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
关键词
EPI; STEPI; stimulated EPI; SESTEPI; spin/stimulated EPI; real-time T-1 mapping; dynamic T-1 mapping; HUMAN-BRAIN; IN-VIVO; EPI; RELAXATION; CORD; MRI;
D O I
10.1002/mrm.22367
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The conventional stimulated-echo NMR sequence only measures the longitudinal component while discarding the transverse component, after tipping up the prepared magnetization. This transverse magnetization can be used to measure a spin echo, in addition to the stimulated echo. Two-dimensional single-shot spin- and stimulated-echo-planar imaging (ss-SESTEPI) is an echo-planar-imaging-based single-shot imaging technique that simultaneously acquires a spin-echo-planar image and a stimulated-echo-planar image after a single radio-frequency excitation. The magnitudes of the spin-echo-planar image and stimulated-echo-planar image differ by T-1 decay and diffusion weighting for perfect 90 degrees radiofrequency and thus can be used to rapidly measure T-1. However, the spatial variation of amplitude of radiofrequency field induces uneven splitting of the transverse magnetization for the spin-echo-planar image and stimulated-echo-planar image within the imaging field of view. Correction for amplitude of radiofrequency field inhomogeneity is therefore critical for two-dimensional ss-SESTEPI to be used for T-1 measurement. We developed a method for amplitude of radiofrequency field inhomogeneity correction by acquiring an additional stimulated-echo-planar image with minimal mixing time, calculating the difference between the spin echo and the stimulated echo and multiplying the stimulated-echo-planar image by the inverse functional map. Diffusion-induced decay is corrected by measuring the average diffusivity during the prescanning. Rapid single-shot T-1 mapping may be useful for various applications, such as dynamic T-1 mapping for real-time estimation of the concentration of contrast agent in dynamic contrast enhancement MRI. Magn Reson Med 64:734-742,2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:734 / 742
页数:9
相关论文
共 14 条
  • [11] Extracting more for less: multi-echo MP2RAGE for simultaneous T1-weighted imaging, T1 mapping, R2*mapping, SWI, and QSM from a single acquisition
    Sun, Hongfu
    Cleary, Jon O.
    Glarin, Rebecca
    Kolbe, Scott C.
    Ordidge, Roger J.
    Moffat, Bradford A.
    Pike, G. Bruce
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (04) : 1178 - 1191
  • [12] Rapid simultaneous acquisition of T1 and T2 mapping images using multishot double spin-echo EPI and automated variations of TR and TE (ms-DSEPI-T12)
    Liu, Xin
    Feng, Yi
    Lu, Zheng-Rong
    Morrell, Glen
    Jeong, Eun-Kee
    NMR IN BIOMEDICINE, 2010, 23 (01) : 97 - 104
  • [13] Simultaneous proton density, T1, T2, and flip-angle mapping of the brain at 7 T using multiparametric 3D SSFP imaging and parallel-transmission universal pulses
    Leroi, Lisa
    Gras, Vincent
    Boulant, Nicolas
    Ripart, Mathilde
    Poirion, Emilie
    Santin, Mathieu D.
    Valabregue, Romain
    Mauconduit, Franck
    Hertz-Pannier, Lucie
    Le Bihan, Denis
    de Rochefort, Ludovic
    Vignaud, Alexandre
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (06) : 3286 - 3299
  • [14] Accurate T1 mapping of short T2 tissues using a three-dimensional ultrashort echo time cones actual flip angle imaging-variable repetition time (3D UTE-Cones AFI-VTR) method
    Ma, Ya-Jun
    Lu, Xing
    Carl, Michael
    Zhu, Yanchun
    Szeverenyi, Nikolaus M.
    Bydder, Graeme M.
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 598 - 608