Single-Shot T1 Mapping Using Simultaneous Acquisitions of Spin- and Stimulated-Echo-Planar Imaging (2D ss-SESTEPI)

被引:7
|
作者
Shi, Xianfeng [2 ]
Kim, Seong-Eun [1 ]
Jeong, Eun-Kee [1 ]
机构
[1] Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Phys, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
关键词
EPI; STEPI; stimulated EPI; SESTEPI; spin/stimulated EPI; real-time T-1 mapping; dynamic T-1 mapping; HUMAN-BRAIN; IN-VIVO; EPI; RELAXATION; CORD; MRI;
D O I
10.1002/mrm.22367
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The conventional stimulated-echo NMR sequence only measures the longitudinal component while discarding the transverse component, after tipping up the prepared magnetization. This transverse magnetization can be used to measure a spin echo, in addition to the stimulated echo. Two-dimensional single-shot spin- and stimulated-echo-planar imaging (ss-SESTEPI) is an echo-planar-imaging-based single-shot imaging technique that simultaneously acquires a spin-echo-planar image and a stimulated-echo-planar image after a single radio-frequency excitation. The magnitudes of the spin-echo-planar image and stimulated-echo-planar image differ by T-1 decay and diffusion weighting for perfect 90 degrees radiofrequency and thus can be used to rapidly measure T-1. However, the spatial variation of amplitude of radiofrequency field induces uneven splitting of the transverse magnetization for the spin-echo-planar image and stimulated-echo-planar image within the imaging field of view. Correction for amplitude of radiofrequency field inhomogeneity is therefore critical for two-dimensional ss-SESTEPI to be used for T-1 measurement. We developed a method for amplitude of radiofrequency field inhomogeneity correction by acquiring an additional stimulated-echo-planar image with minimal mixing time, calculating the difference between the spin echo and the stimulated echo and multiplying the stimulated-echo-planar image by the inverse functional map. Diffusion-induced decay is corrected by measuring the average diffusivity during the prescanning. Rapid single-shot T-1 mapping may be useful for various applications, such as dynamic T-1 mapping for real-time estimation of the concentration of contrast agent in dynamic contrast enhancement MRI. Magn Reson Med 64:734-742,2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:734 / 742
页数:9
相关论文
共 14 条
  • [1] Single-Shot T2 Mapping Through OverLapping-Echo Detachment (OLED) Planar Imaging
    Cai, Congbo
    Zeng, Yiqing
    Zhuang, Yuchuan
    Cai, Shuhui
    Chen, Lin
    Ding, Xinghao
    Bao, Lijun
    Zhong, Jianhui
    Chen, Zhong
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (10) : 2450 - 2461
  • [2] Diffusion tensor imaging focusing on lower cervical spinal cord using 2D reduced FOV interleaved multislice single-shot diffusion-weighted echo-planar imaging: comparison with conventional single-shot diffusion-weighted echo-planar imaging
    Park, Eun Hae
    Lee, Young Han
    Jeong, Eun-Kee
    Roh, Yun Ho
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2015, 33 (04) : 401 - 406
  • [3] Accelerated liver water T1 mapping using single-shot continuous inversion-recovery spiral imaging
    Moquillaza, Elizabeth Huaroc
    Weiss, Kilian
    Stelter, Jonathan
    Steinhelfer, Lisa
    Lee, Yoo Jin
    Amthor, Thomas
    Koken, Peter
    Makowski, Marcus R.
    Braren, Rickmer
    Doneva, Mariya
    Karampinos, Dimitrios C.
    NMR IN BIOMEDICINE, 2024, 37 (05)
  • [4] Multislice T1-prepared 2D single-shot EPI: analysis of a clinical T1 mapping method unbiased by B0 or B1 inhomogeneity
    Lauzon, M. Louis
    McCreary, Cheryl R.
    Frayne, Richard
    NMR IN BIOMEDICINE, 2016, 29 (08) : 1056 - 1069
  • [5] Diffusion-Weighted Imaging of Human Carotid Artery Using 2D Single-Shot Interleaved Multislice Inner Volume Diffusion-Weighted Echo Planar Imaging (2D ss-IMIV-DWEPI) at 3T: Diffusion Measurement in Atherosclerotic Plaque
    Kim, Seong-Eun
    Jeong, Eun-Kee
    Shi, Xian-Feng
    Morrell, Glen
    Treiman, Gerald S.
    Parker, Dennis L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) : 1068 - 1077
  • [6] Single-shot T2 mapping via multi-echo-train multiple overlapping-echo detachment planar imaging and multitask deep learning
    Ouyang, Binyu
    Yang, Qizhi
    Wang, Xiaoyin
    He, Hongjian
    Ma, Lingceng
    Yang, Qinqin
    Zhou, Zihan
    Cai, Shuhui
    Chen, Zhong
    Wu, Zhigang
    Zhong, Jianhui
    Cai, Congbo
    MEDICAL PHYSICS, 2022, 49 (11) : 7095 - 7107
  • [7] Focal liver lesion detection and characterization: Comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging
    Coenegrachts, Kenneth
    Matos, Celso
    ter Beek, Leon
    Metens, Thierry
    Haspeslagh, Marc
    Bipat, Shandra
    Stoker, Jaap
    Rigauts, Hans
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (03) : 432 - 439
  • [8] Model-based reconstruction for simultaneous multi-slice T1 mapping using single-shot inversion-recovery radial FLASH
    Wang, Xiaoqing
    Rosenzweig, Sebastian
    Scholand, Nick
    Holme, H. Christian M.
    Uecker, Martin
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (03) : 1258 - 1271
  • [9] Analysis of ascending spinal tract degeneration in cervical spondylotic myelopathy using 3D anisotropy contrast single-shot echo planar imaging on a 3.0-T system
    Urakawa, Takaaki
    Matsuzawa, Hitoshi
    Suzuki, Yuji
    Endo, Naoto
    Kwee, Ingrid L.
    Nakada, Tsutomu
    JOURNAL OF NEUROSURGERY-SPINE, 2011, 15 (06) : 648 - 653
  • [10] Multi-echo single-shot spectroscopy combined with simultaneous 2D model fitting for fast and accurate measurement of metabolite-specific concentrations and T2 relaxation times
    Rizzo, Rudy
    Kreis, Roland
    NMR IN BIOMEDICINE, 2023, 36 (12)