Methylated DNA impedimetric immunosensor based on azo-polymer-AuNPs dots and 5-methylcytosine antibody using dissolved oxygen as a redox probe

被引:14
作者
Olean-Oliveira, Andre [1 ]
Seraphim, Patricia Monteiro [2 ]
Teixeira, Marcos F. S. [1 ]
机构
[1] Sao Paulo State Univ UNESP, Sch Sci & Technol, Dept Chem & Biochem, Rua Roberto Simonsen 305, BR-19060900 Presidente Prudente, SP, Brazil
[2] Sao Paulo State Univ UNESP, Sch Sci & Technol, Dept Physiotherapy, Rua Roberto Simonsen 305, BR-19060900 Presidente Prudente, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Methylated DNA sensor; Immunosensor; Gold nanoparticle-polymer; Methylcytosine antibody; Secondary antibody less; BIOSENSOR; BLOCKING; PROTEIN; ENZYME; SENSOR;
D O I
10.1016/j.elecom.2022.107242
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The present work describes the development of an electrochemical immunosensor for the direct determination of methylated DNA using dissolved oxygen as the redox probe. The oxygen-sensitive response is possible due to the presence of a redox conducting polymer based on the Bismarck Brown Y dye (poly(azo-BBY)). In addition to the azo-polymer, gold nanoparticles (AuNPs) were formed in the polymer film by encapsulation to increase the active surface area and enhance sensor performance. The platform was easily synthesized using a single-step electropolymerization technique in a solution containing the BBY monomer and HAuCl4 salt. The immunosensor was developed by simply immobilizing the 5-methylcytosine antibody (Ab-5-mC) with high affinity to 5mC on the surface of a device coated with azo-polymer-AuNPs dots. No secondary antibodies or enzymes were used in constructing this device. The immunosensor performance was evaluated by electrochemical impedance spectroscopy (EIS) in different concentrations of 5-methylcytosine (5-mC) in 0.10 mol L-1 phosphate buffer solution (PBS) solution containing atmospheric oxygen. A calibration curve was obtained by varying the resistance of the system as a function of the 5-mC concentration, revealing a limit of detection (LOD) in picograms per milliliter.
引用
收藏
页数:6
相关论文
共 31 条
[1]   Reagentless Redox Capacitive Assaying of C-Reactive Protein at a Polyaniline Interface [J].
Baradoke, Ausra ;
Hein, Robert ;
Li, Xiaoxiong ;
Davis, Jason J. .
ANALYTICAL CHEMISTRY, 2020, 92 (05) :3508-3511
[2]   ESSENCE-A rapid, shear-enhanced, flow-through, capacitive electrochemical platform for rapid detection of biomolecules [J].
Cheng, Yu-Hsuan ;
Kargupta, Roli ;
Ghoshal, Debjit ;
Li, Zhenglong ;
Chande, Charmi ;
Feng, Lixin ;
Chatterjee, Sayandev ;
Koratkar, Nikhil ;
Motkuri, Radha Kishan ;
Basuray, Sagnik .
BIOSENSORS & BIOELECTRONICS, 2021, 182 (182)
[3]   Electrical pulse-induced electrochemical biosensor for hepatitis E virus detection [J].
Chowdhury, Ankan Dutta ;
Takemura, Kenshin ;
Li, Tian-Cheng ;
Suzuki, Tetsuro ;
Park, Enoch Y. .
NATURE COMMUNICATIONS, 2019, 10 (1)
[4]   Electrochemical Nucleation and Growth of Gold Nanoparticles on Single-Walled Carbon Nanotubes: New Mechanistic Insights [J].
Dudin, Petr V. ;
Unwin, Patrick R. ;
Macpherson, Julie V. .
JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (31) :13241-13248
[5]   Conducting polymer-noble metal nanoparticle hybrids: Synthesis mechanism application [J].
Han, Jie ;
Wang, Minggui ;
Hu, Yimin ;
Zhou, Chuanqiang ;
Guo, Rong .
PROGRESS IN POLYMER SCIENCE, 2017, 70 :52-91
[6]   Optical biosensing strategies for DNA methylation analysis [J].
Islam, Md. Nazmul ;
Yadav, Sharda ;
Hague, Md. Hakimul ;
Munaz, Ahmed ;
Islam, Farhadul ;
Al Hossain, Md Shahriar ;
Gopalan, Vinod ;
Lam, Alfred K. ;
Nam-Trung Nguyen ;
Shiddiky, Muhammad J. A. .
BIOSENSORS & BIOELECTRONICS, 2017, 92 :668-678
[7]   A critical review on the use of potentiometric based biosensors for biomarkers detection [J].
Karimi-Maleh, Hassan ;
Orooji, Yasin ;
Karimi, Fatemeh ;
Alizadeh, Marzieh ;
Baghayeri, Mehdi ;
Rouhi, Jalal ;
Tajik, Somayeh ;
Beitollahi, Hadi ;
Agarwal, Shilpi ;
Gupta, Vinod K. ;
Rajendran, Saravanan ;
Ayati, Ali ;
Fu, Li ;
Sanati, Afsaneh L. ;
Tanhaei, Bahareh ;
Sen, Fatih ;
Shabani-nooshabadi, Mehdi ;
Asrami, Padideh Naderi ;
Al-Othman, Amani .
BIOSENSORS & BIOELECTRONICS, 2021, 184 (184)
[8]   Electrochemical biosensors for the detection of lung cancer biomarkers: A review [J].
Khanmohammadi, Akbar ;
Aghaie, Ali ;
Vahedi, Ensieh ;
Qazvini, Ali ;
Ghanei, Mostafa ;
Afkhami, Abbas ;
Hajian, Ali ;
Bagheri, Hasan .
TALANTA, 2020, 206
[9]  
Kurdyukov Sergey, 2016, Biology-Basel, V5, DOI 10.3390/biology5010003
[10]   "Gate Effect" in p-Synephrine Electrochemical Sensing with a Molecularly Imprinted Polymer and Redox Probes [J].
Lach, Patrycja ;
Cieplak, Maciej ;
Majewska, Marta ;
Noworyta, Krzysztof R. ;
Sharma, Piyush Sindhu ;
Kutner, Wlodzimierz .
ANALYTICAL CHEMISTRY, 2019, 91 (12) :7546-7553