Lean Body Weight-Tailored Iodinated Contrast Injection in Obese Patient: Boer versus James Formula

被引:35
作者
Caruso, Damiano [1 ]
De Santis, Domenico [1 ]
Rivosecchi, Flaminia [2 ]
Zerunian, Marta [2 ]
Panvini, Nicola [2 ]
Montesano, Marta [2 ]
Biondi, Tommaso [1 ]
Bellini, Davide [2 ]
Rengo, Marco [2 ]
Laghi, Andrea [1 ]
机构
[1] Sapienza Univ Rome, St Andrea Univ Hosp, Dept Radiol Oncol & Pathol Sci, Via Grottarossa 1035, Rome, Italy
[2] Sapienza Univ Rome, Dept Radiol Oncol & Pathol Sci, Via Franco Faggiana 1668, Latina, Italy
关键词
MULTIDETECTOR ROW CT; HEPATIC ENHANCEMENT; SURFACE AREA; BLOOD-VOLUME; DYNAMIC CT; MASS INDEX; APPROPRIATE; HEIGHT; LIVER; MDCT;
D O I
10.1155/2018/8521893
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. To prospectively compare the performance of James and Boer formula in contrast media (CM) administration, in terms of image quality and parenchymal enhancement in obese patients undergoing CT of the abdomen. Materials and Methods. Fifty-five patients with a body mass index (BMI) greater than 35 kg/m(2) were prospectively included in the study. All patients underwent 64-row CT examination and were randomly divided in two groups: 26 patients in Group A and 29 patients in Group B. The amount of injected CM was computed according to the patient's lean body weight (LBW), estimated using either Boer formula (Group A) or James formula (Group B). Patient's characteristics, CM volume, contrast-to-noise ratio (CNR) of liver, aorta and portal vein, and liver contrast enhancement index (CEI) were compared between the two groups. For subjective image analysis readers were asked to rate the enhancement of liver, kidneys, and pancreas based on a 5-point Likert scale. Results. Liver CNR, aortic CNR, and portal vein CNR showed no significant difference between Group A and Group B (all P >= 0.177). Group A provided significantly higher CEI compared to Group B (P = 0.007). Group A and Group B returned comparable overall subjective enhancement values (3.54 and vs 3.20, all P >= 0.199). Conclusions. Boer formula should be the method of choice for LBW estimation in obese patients, leading to an accurate CM amount calculation and an optimal liver contrast enhancement in CT.
引用
收藏
页数:6
相关论文
共 26 条
[1]   Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight [J].
Awai, K ;
Hiraishi, K ;
Hori, S .
RADIOLOGY, 2004, 230 (01) :142-150
[2]   Aortic and hepatic enhancement and tumor-to-liver contrast: Analysis of the effect of different concentrations of contrast material at multi-detector row helical CV [J].
Awai, K ;
Takada, K ;
Onishi, H ;
Hori, S .
RADIOLOGY, 2002, 224 (03) :757-763
[3]   The Optimal Body Size Index with Which to Determine Iodine Dose for Hepatic Dynamic CT: A Prospective Multicenter Study [J].
Awai, Kazuo ;
Kanematsu, Masayuki ;
Kim, Tonsok ;
Ichikawa, Tomoaki ;
Nakamura, Yuko ;
Nakamoto, Atsushi ;
Yoshioka, Kunihiro ;
Mochizuki, Teruhito ;
Matsunaga, Naofumi ;
Yamashita, Yasuyuki .
RADIOLOGY, 2016, 278 (03) :773-781
[4]   Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :657-662
[5]   Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches [J].
Bae, Kyongtae T. .
RADIOLOGY, 2010, 256 (01) :32-61
[6]   ESTIMATED LEAN BODY-MASS AS AN INDEX FOR NORMALIZATION OF BODY-FLUID VOLUMES IN HUMANS [J].
BOER, P .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 247 (04) :F632-F636
[7]   HEPATIC SPIRAL CT - REDUCTION OF DOSE OF INTRAVENOUS CONTRAST MATERIAL [J].
BRINK, JA ;
HEIKEN, JP ;
FORMAN, HP ;
SAGEL, SS ;
MOLINA, PL ;
BROWN, PC .
RADIOLOGY, 1995, 197 (01) :83-88
[8]  
Dahlman P., 2016, ACTA RADIOL, V41, P361
[9]  
Goshima Satoshi, 2006, AJR Am J Roentgenol, V187, pW25, DOI 10.2214/AJR.04.1878
[10]   DYNAMIC INCREMENTAL CT - EFFECT OF VOLUME AND CONCENTRATION OF CONTRAST MATERIAL AND PATIENT WEIGHT ON HEPATIC ENHANCEMENT [J].
HEIKEN, JP ;
BRINK, JA ;
MCCLENNAN, BL ;
SAGEL, SS ;
CROWE, TM ;
GAINES, MV .
RADIOLOGY, 1995, 195 (02) :353-357