Thermal Characterization of Interlayer Microfluidic Cooling of Three-Dimensional Integrated Circuits With Nonuniform Heat Flux

被引:87
作者
Kim, Yoon Jo [1 ]
Joshi, Yogendra K. [1 ]
Fedorov, Andrei G. [1 ]
Lee, Young-Joon [2 ]
Lim, Sung-Kyu [2 ]
机构
[1] Georgia Inst Technol, GW Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
来源
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME | 2010年 / 132卷 / 04期
关键词
cooling; integrated circuit interconnections; integrated circuit packaging; microchannel flow; microprocessor chips; refrigerants; thermal management (packaging); two-phase flow; PRESSURE-DROP; 2-PHASE FLOW; PERFORMANCE EVALUATION; HOTSPOT; DESIGN; SYSTEM; MICROCHANNELS; CHANNELS; SINK;
D O I
10.1115/1.4000885
中图分类号
O414.1 [热力学];
学科分类号
摘要
It is now widely recognized that the three-dimensional (3D) system integration is a key enabling technology to achieve the performance needs of future microprocessor integrated circuits (ICs). To provide modular thermal management in 3D-stacked ICs, the interlayer microfluidic cooling scheme is adopted and analyzed in this study focusing on a single cooling layer performance. The effects of cooling mode (single-phase versus phase-change) and stack/layer geometry on thermal management performance are quantitatively analyzed, and implications on the through-silicon-via scaling and electrical interconnect congestion are discussed. Also, the thermal and hydraulic performance of several two-phase refrigerants is discussed in comparison with single-phase cooling. The results show that the large internal pressure and the pumping pressure drop are significant limiting factors, along with significant mass flow rate maldistribution due to the presence of hot-spots. Nevertheless, two-phase cooling using R123 and R245ca refrigerants yields superior performance to single-phase cooling for the hot-spot fluxes approaching similar to 300 W/cm(2). In general, a hybrid cooling scheme with a dedicated approach to the hot-spot thermal management should greatly improve the two-phase cooling system performance and reliability by enabling a cooling-load-matched thermal design and by suppressing the mass flow rate maldistribution within the cooling layer.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 53 条
[1]   3D Heterogeneous Integrated Systems: Liquid Cooling, Power Delivery, and Implementation [J].
Bakir, Muhannad S. ;
King, Calvin ;
Sekar, Deepak ;
Thacker, Hiren ;
Dang, Bing ;
Huang, Gang ;
Naeemi, Azad ;
Meindl, James D. .
PROCEEDINGS OF THE IEEE 2008 CUSTOM INTEGRATED CIRCUITS CONFERENCE, 2008, :663-670
[2]   3-D ICs: A novel chip design for improving deep-submicrometer interconnect performance and systems-on-chip integration [J].
Banerjee, K ;
Souri, SJ ;
Kapur, P ;
Saraswat, KC .
PROCEEDINGS OF THE IEEE, 2001, 89 (05) :602-633
[3]   A closed-loop electronics cooling by implementing single phase impinging jet and mini channels heat exchanger [J].
Bintoro, JS ;
Akbarzadeh, A ;
Mochizuki, M .
APPLIED THERMAL ENGINEERING, 2005, 25 (17-18) :2740-2753
[4]  
BLASIUS H, 1913, 131 FORSCH VER DTSCH
[5]  
Bohr MT, 1995, INTERNATIONAL ELECTRON DEVICES MEETING, 1995 - IEDM TECHNICAL DIGEST, P241, DOI 10.1109/IEDM.1995.499187
[6]   Design challenges of technology scaling [J].
Borkar, S .
IEEE MICRO, 1999, 19 (04) :23-29
[7]   Forced convective interlayer cooling in vertically integrated packages [J].
Brunschwiler, Thomas ;
Michel, B. ;
Rothuizen, Hugo ;
Kloter, U. ;
Wunderle, B. ;
Oppermann, H. ;
Reichl, H. .
2008 11TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, VOLS 1-3, 2008, :1114-+
[8]  
COLLIER JG, 1981, CONVECTIVE BOILING C, P37
[9]   Integrated thermal-fluidic I/O interconnects for an on-chip microchannel heat sink [J].
Dang, B ;
Bakir, MS ;
Meindl, JD .
IEEE ELECTRON DEVICE LETTERS, 2006, 27 (02) :117-119
[10]   SiGeC/Si superlattice microcoolers [J].
Fan, XF ;
Zeng, GH ;
LaBounty, C ;
Bowers, JE ;
Croke, E ;
Ahn, CC ;
Huxtable, S ;
Majumdar, A ;
Shakouri, A .
APPLIED PHYSICS LETTERS, 2001, 78 (11) :1580-1582