Detection of colorectal cancer hepatic metastases with contrast-enhanced ultrasound: Comparison with conventional B-mode ultrasound

被引:13
作者
Yarmenitis, S. D. [1 ]
Karantanas, A. [1 ]
Bakantaki, A. [1 ]
Papantoniou, Y. [1 ]
Gourtsoyiannis, N. [1 ]
机构
[1] Univ Crete, Fac Med, Dept Radiol, Iraklion, Greece
关键词
colorectal cancer/imaging; liver neoplasms/ultrasonography; contrast media; metastatic disease/diagnosis;
D O I
10.1159/000099175
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
The aim of this study was to assess whether contrast-enhanced ultrasound (CE-US) could provide improved diagnostic information in detecting liver metastases from colorectal cancer as compared to B-mode non-enhanced ultrasound (B-US). 32 patients (M/F 23/9, age range 48-82 years, mean 58.2 years) under chemotherapy for colorectal cancer were examined with B-US and CE-US using a second-generation ultrasound contrast agent and a dedicated protocol for contrast detection. The presence of focal liver lesions along with the number, size, pre- and post-contrast sonographic features were recorded digitally. Lesion conspicuity with a three-grade scoring scale was performed on both techniques and contrast intensity measurements were calculated for each focal lesion. CE-US detected 17% more metastases in patient-by-patient and lesion-by-lesion analysis. A statistically significant difference was found between the scoring mean values with regard to conspicuity of the lesions. Accurate characterization of the liver lesions was achievable only with contrast-enhanced technique. A quantitative contrast intensity measurement method confirmed the invariably washing-out vascular pattern in all metastases at sinusoidal-parenchymal liver phase. In conclusion, CE-US is superior to B-US and provides an effective tool in the investigation of colorectal cancer liver metastases. Copyright (c) 2007 S. Karger AG, Basel
引用
收藏
页码:86 / 93
页数:8
相关论文
共 14 条
[1]   Improved detection of hepatic metastases with pulse-inversion US during the liver-specific phase of SHU 508A: Multicenter study [J].
Albrecht, T ;
Blomley, MJK ;
Burns, PN ;
Wilson, S ;
Harvey, CJ ;
Leen, E ;
Claudon, M ;
Calliada, F ;
Correas, JM ;
LaFortune, M ;
Campani, R ;
Hoffmann, CW ;
Cosgrove, DO ;
LeFevre, F .
RADIOLOGY, 2003, 227 (02) :361-370
[2]   Incidental liver lesions: diagnostic value of cadence contrast pulse sequencing (CPS) and SonoVue [J].
Bleuzen, A ;
Tranquart, F .
EUROPEAN RADIOLOGY, 2004, 14 :P53-P62
[3]   Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: Early experience [J].
Blomley, MJK ;
Albrecht, T ;
Cosgrove, DO ;
Patel, N ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, RJ ;
Bauer, A ;
Schlief, R .
RADIOLOGY, 1999, 210 (02) :409-416
[4]  
COSGROVE DO, 1993, ABDOMINAL GEN ULTRAS, P271
[5]   Hepatic malignancies: Improved detection with pulse-inversion US in late phase of enhancement with SHU 508A - Early experience [J].
Harvey, CJ ;
Blomley, MJK ;
Eckersley, RJ ;
Cosgrove, DO ;
Patel, N ;
Heckemann, RA ;
Butler-Barnes, J .
RADIOLOGY, 2000, 216 (03) :903-908
[6]   Ultrasound of focal liver lesions [J].
Harvey, CJ ;
Albrecht, T .
EUROPEAN RADIOLOGY, 2001, 11 (09) :1578-1593
[7]   Ultrasonographic detection of focal liver lesions: increased sensitivity and specificity with microbubble contrast agents [J].
Hohmann, J ;
Albrecht, T ;
Hoffmann, CW ;
Wolf, KJ .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 46 (02) :147-159
[8]   Monitoring of liver metastases after stereotactic radiotherapy using low-Ml contrast-enhanced ultrasound - initial results [J].
Krix, M ;
Plathow, C ;
Essig, M ;
Herfarth, K ;
Debus, J ;
Kauczor, HU ;
Delorme, S .
EUROPEAN RADIOLOGY, 2005, 15 (04) :677-684
[9]   Detection of hepatic metastases with low MI real time contrast enhanced sonography and SonoVue® [J].
Oldenburg, A ;
Hohmann, J ;
Foert, E ;
Skrok, J ;
Hoffmann, CW ;
Frericks, B ;
Wolf, KJ ;
Albrecht, T .
ULTRASCHALL IN DER MEDIZIN, 2005, 26 (04) :277-284
[10]   Characterization of focal liver lesions with contrast specific US modes and a sulfur hexafluoride-filled microbubble contrast agent: Diagnostic performance and confidence [J].
Quaia, E ;
Calliada, F ;
Bertolotto, M ;
Rossi, S ;
Garioni, L ;
Rosa, L ;
Pozzi-Mucelli, R .
RADIOLOGY, 2004, 232 (02) :420-430