Custom-fit kinematic alignment in total knee arthroplasty using PSI. The story of ShapeMatch technology

被引:0
作者
Calliess, T. [1 ]
Ettinger, M. [1 ]
Stukenborg-Colsmann, C. [1 ]
Windhagen, H. [1 ]
机构
[1] Med Hsch Hannover Annastift, Dept Endoprothet & Rekonstrukt Gelenkchirurg, Orthopad Klin, Anna von Borries Str 3, D-30449 Hannover, Germany
来源
ORTHOPADE | 2016年 / 45卷 / 04期
关键词
Primary total knee arthroplasty; Kinematic alignment; Review; Patient specific intruments; Stryker ShapeMatch (R); INSTRUMENTATION; TRIAL;
D O I
10.1007/s00132-016-3240-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. The story of ShapeMatchA (R) custom-fit cutting guides for primary total knee arthroplasty (TKA) is special compared to other available techniques. First, it was the first such patient-specific instrument (PSI) on the market. Second, the underlying philosophy of kinematic alignment is unique compared to other competitors. Finally, it is the only PSI technique that has been withdrawn from the market. Objectives and methods. The objective of this paper is to summarize the history of the ShapeMatchA (R) technology and to review the current literature regarding clinical evidence for kinematically aligned TKA. Results and conclusions. In the recent literature, faster rehabilitation, better knee function and higher patient satisfaction are described for kinematically aligned TKA compared to conventional alignment. However, there is also evidence for inaccuracies by using the PSI technology as a possible cause of treatment failures. Due to those problems, this technology was recalled from the market. As an alternative method to achieve kinematic alignment in TKA, manual as well as computer-assisted techniques are currently under development and are discussed here.
引用
收藏
页码:314 / +
页数:7
相关论文
共 18 条
  • [1] Kinematic alignment in total knee arthroplasty. Concept, evidence base and limitations
    Calliess, T.
    Ettinger, M.
    Stukenborg-Colsmann, C.
    Windhagen, H.
    [J]. ORTHOPADE, 2015, 44 (04): : 282 - +
  • [2] Calliess T, 2014, ORTHOPADE, V43, P529, DOI 10.1007/s00132-014-2298-y
  • [3] Calliess T, 2013, COMPUTER TEMPLATE AS, P63
  • [4] Intra-operative reliability of ShapeMatch cutting guide placement in total knee arthroplasty
    Clark, Gavin
    Leong, Anthony
    McEwen, Peter
    Steele, Robert
    Tran, Ton
    Trivett, Adrian
    [J]. COMPUTER AIDED SURGERY, 2013, 18 (5-6) : 159 - 165
  • [5] A randomised controlled trial of kinematically and mechanically aligned total knee replacements TWO-YEAR CLINICAL RESULTS
    Dossett, H. G.
    Estrada, N. A.
    Swartz, G. J.
    LeFevre, G. W.
    Kwasman, B. G.
    [J]. BONE & JOINT JOURNAL, 2014, 96B (07) : 907 - 913
  • [6] Kinematically Versus Mechanically Aligned Total Knee Arthroplasty
    Dossett, H. Gene
    Swartz, George J.
    Estrada, Nicolette A.
    LeFevre, George W.
    Kwasman, Bertram G.
    [J]. ORTHOPEDICS, 2012, 35 (02) : E160 - E169
  • [7] Ettinger M, 2014, DTSCH K ORTH UNF BER
  • [8] Haaker R, 2013, COMPUTER TEMPLATE AS, pS3
  • [9] Howell SM, 2011, SURG KNEE, pS1255
  • [10] Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients
    Howell, Stephen M.
    Kuznik, Kyle
    Hull, Maury L.
    Siston, Robert A.
    [J]. ORTHOPEDICS, 2008, 31 (09) : 857 - 863