Point-of-care urine albumin in general practice offices: effect of participation in an external quality assurance scheme

被引:9
作者
Bukve, Tone [1 ,2 ]
Roraas, Thomas [2 ]
Riksheim, Berit Oddny [2 ]
Christensen, Nina Gade [2 ]
Sandberg, Sverre [2 ,3 ]
机构
[1] Noklus, N-5892 Bergen, Norway
[2] Haraldsplass Deaconess Hosp, Norwegian Qual Improvement Primary Care Labs Nokl, Bergen, Norway
[3] Univ Bergen, Fac Med & Dent, Dept Global Hlth & Primary Care, Bergen, Norway
关键词
external quality assurance schemes; point-of-care testing; primary health care; urine albumin; DIABETIC-NEPHROPATHY; CARDIOVASCULAR-DISEASE; MANAGEMENT; MICROALBUMINURIA; CREATININE; STORAGE;
D O I
10.1515/cclm-2014-0483
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The Norwegian Quality Improvement of Primary Care Laboratories (Noklus) offers external quality assurance (EQA) schemes (EQASs) for urine albumin (UA) annually. This study analyzed the EQA results to determine how the analytical quality of UA analysis in general practice (GP) offices developed between 1998 (n=473) and 2012 (n=1160). Methods: Two EQA urine samples were distributed yearly to the participants by mail. The participants measured the UA of each sample and returned the results together with information about their instrument, the profession and number of employees at the office, frequency of internal quality control (IQC), and number of analyses per month. In the feedback report, they received an assessment of their analytical performance. Results: The number of years that the GP office had participated in Noklus was inversely related to the percentage of "poor" results for quantitative but not semi-quantitative instruments. The analytical quality improved for participants using quantitative instruments who received an initial assessment of "poor" and who subsequently changed their instrument. Participants using reagents that had expired or were within 3 months of the expiration date performed worse than those using reagents that were expiring in more than 3 months. Conclusions: Continuous participation in the Noklus program improved the performance of quantitative UA analyses at GP offices. This is probably in part attributable to the complete Noklus quality system, whereby in addition to participating in EQAS, participants are visited by laboratory consultants who examine their procedures and provide practical advice and education regarding the use of different instruments.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 35 条
[1]  
Amer Diabet Assoc, 2011, DIABETES CARE, V34, pS11, DOI [10.2337/dc11-S062, 10.2337/dc14-S081, 10.2337/dc11-S011, 10.2337/dc13-S067, 10.2337/dc12-s011, 10.2337/dc10-S011, 10.2337/dc10-S062, 10.2337/dc13-S011, 10.2337/dc12-s064]
[2]   Comments on 'KDIGO 2012 clinical practice guideline for the evaluation and management of chronic kidney disease' [J].
Andrassy, Konrad M. .
KIDNEY INTERNATIONAL, 2013, 84 (03) :622-623
[3]  
[Anonymous], FUND EXT QUAL ASS EQ
[4]  
[Anonymous], SCAND EV LAB EQ PRIM
[5]  
[Anonymous], HLTH TECHNOL ASSESS
[6]  
[Anonymous], 2005, 13528 ISO
[7]  
[Anonymous], AM J KIDNEY DIS
[8]  
[Anonymous], Global guideline for type 2 diabetes
[9]  
[Anonymous], BAS GEN CONC ASS TER
[10]  
[Anonymous], USING PROFICIENCY TE