Prediction of chlorine and trihalomethanes concentration profile in bulk drinking water distribution systems from laboratory data

被引:14
作者
Kastl, G [1 ]
Fisher, I [1 ]
Jegatheesan, V [1 ]
Chandy, J [1 ]
Clarkson, K [1 ]
机构
[1] Sydney Water Corp, CRC Water Qual & Treatment, W Ryde, NSW 2114, Australia
来源
3RD WORLD WATER CONGRESS: WATER SERVICES MANAGEMENT, OPERATIONS AND MONITORING | 2003年 / 3卷 / 1-2期
关键词
chlorine decay; drinking water distribution; system optimisation; trihalomethanes; water quality; modelling;
D O I
10.2166/ws.2003.0110
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Nearly all drinking water distribution systems experience a "natural" reduction of disinfection residuals. The most frequently used disinfectant is chlorine, which can decay due to reactions with organic and inorganic compounds in the water and by liquid/solids reaction with the biofilm, pipe walls and sediments. Usually levels of 0.2-0.5 mg/L of free chlorine are required at the point of consumption to maintain bacteriological safety. Higher concentrations are not desirable as they present the problems of taste and odour and increase formation of disinfection by-products. It is usually a considerable concern for the operators of drinking water distribution systems to manage chlorine residuals at the "optimum level", considering all these issues. This paper describes how the chlorine profile in a drinking water distribution system can be modelled and optimised on the basis of readily and inexpensively available laboratory data. Methods are presented for deriving the laboratory data, fitting a chlorine decay model of bulk water to the data and applying the model, in conjunction with a simplified hydraulic model, to obtain the chlorine profile in a distribution system at steady flow conditions. Two case studies are used to demonstrate the utility of the technique. Melbourne's Greenvale-Sydenham distribution system is unfiltered and uses chlorination as its only treatment. The chlorine model developed from laboratory data was applied to the whole system and the chlorine profile was shown to be accurately simulated. Biofilm was not found to critically affect chlorine decay. In the other case study, Sydney Water's Nepean system was modelled from limited hydraulic data. Chlorine decay and trihalomethane (THM) formation in raw and treated water were measured in a laboratory, and a chlorine decay and THM model was derived on the basis of these data. Simulated chlorine and THM profiles agree well with the measured values available. Various applications of this modelling approach are also briefly discussed.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 8 条
[1]  
*AWT, 2001, 20010153 SYDN WAT CO
[2]  
CLARK R, 1998, J ENV ENG, P16
[3]  
*COOP RES CTR WAT, 2001, 20002001 COOP RES CT
[4]  
KASTL G, 2001, AWA 19 CONV CANB AUS
[5]   Evaluation of chlorine decay kinetics expressions for drinking water distribution systems modelling [J].
Kastl, GJ ;
Fisher, IH ;
Jegatheesan, V .
JOURNAL OF WATER SERVICES RESEARCH AND TECHNOLOGY-AQUA, 1999, 48 (06) :219-226
[6]   DESIGN TECHNIQUES OF A COMPUTER-PROGRAM FOR THE IDENTIFICATION OF PROCESSES AND THE SIMULATION OF WATER-QUALITY AQUATIC SYSTEMS [J].
REICHERT, P .
ENVIRONMENTAL SOFTWARE, 1995, 10 (03) :199-210
[7]  
Rossman L. A., 2000, EPANET 2 USERS MANUA
[8]  
SUNG W, 2001, JAWWA, P101